Laserfiche WebLink
PageREVISIONS:Project Name3.520 kW (DC) / 3.202 kW (CEC-AC)PHOTOVOLTAIC SYSTEMMCFADDEN AVE849 E MCFADDEN AVE UNIT 2,SANTA ANA, CA 92707APN: 011-224-15DATE:03/21/2024DRAWN BY:TYContractors Signature:PREMIER BUILDERS & HARDSCAPE INC8832 LA GRAND AVEGARDEN GROVE, CA 92841PHONE: (714) 467-9018LICENSE: #995068/B,C53PLOT PLANBUILDING SPECIFICATIONS <br />TYPE:S.F.D <br />STORIES:1 <br />BUILDING HEIGHT(FT.):12 <br />BUILDING(SQ.FT):749 <br />ROOF SLOPES(°):18 <br />ROOF FRAME MEMBER:2X10 RAFTERS <br />O.C. SPACING(IN.):16 <br />MAX SPAN:14'-0" IN BETWEEN SUPPORTS <br />MIN LAG BOLT <br />EMBEDMENT(IN.):2-1/2 <br />MOUNTING AND STANDOFF <br />SPECIFICATIONS <br />ROOFING MATERIAL:SINGLE LAYER COMP <br />RACKING SYSTEM:IRONRIDGE <br />STANDOFF DISTANCE(IN.):64 <br />MOUNTING TYPE:FLUSH MOUNT <br />TILT LEG HEIGHT (IN.):N/A <br />HEIGHT OF PV MODULE <br />ABOVE ROOF SURFACE:3" TO 5" <br />MAX CANTILEVER (IN.):24 <br />SYSTEM SPECIFICATIONS <br />SIZE(kW):3.520 <br />MODULE:(8) URE SOLAR FAM440E8G-BB <br />INVERTER(S):(8) ENPHASE IQ8PLUS-72-2-US <br />INVERTER TYPE:MICRO-INVERTER <br />STRING SCHEDULE:1 CIRCUIT(S) OF 8 MODULES <br />SYSTEM WEIGHT(LBS):470.32 <br />ARRAY AREA(SQ.FT):190.23 <br />ARRAY AZIMUTH(°):180 <br />LBS/SQ.FT:2.47 <br />03 OF 11 <br />ROOF MOUNTED NOTES: <br />ADDITIONAL BUILDING DATA <br />TOTAL ARRAY AREA (SQ. FT.):190.23 <br />TOTAL PLAN VIEW ROOF AREA (SQ. FT.):749 <br />OCCUPYING PV PERCENTAGE:25.40% <br />SPRINKLER SYSTEM INSTALLED (IFC 903.3.1.3)NO <br />- SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED <br /> ON RESIDENTIAL STRUCTURE (GROUP R3 BUILDINGS). <br />-THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM <br /> THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. <br />-A 36-INCH WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY <br />ESCAPE AND RESCUE OPENING(S). <br />-IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE <br /> GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY <br /> TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. <br />R324.6.1 Pathways <br />R324.6.2 Setback at ridge <br />R324.6.2.1 Alternative setback at ridge <br />Exceptions: <br />1. These requirements shall not apply to structures designed and <br />constructed in accordance with the International Residential Code. <br />2. These requirements shall not apply to roofs with slopes of 2 <br />units vertical in 12 units horizontal or less. <br />ROOF ACCESS POINTS PER <br />2022 CRC, R324 (IFC 1204)MA/CD.PVLCMSPJB <br />N <br />S <br />EW <br />Scale: 1/8" = 1'-0" <br />(For 11x17 Print) <br />3' <br />1'-6" <br />3' <br />ROOF ACCESS POINT <br />(STREET-SIDE) <br />(N) 30A AC DISCONNECT 2P - NON FUSIBLE <br />(N) ENPHASE AC COMBINER BOX 240VAC, NEMA 3R <br />(E) DUAL ELECTRICAL METERS OF <br />MAIN HOUSE AND ADU <br />EXTERIOR CONDUIT (7/8"+ ABOVE ROOF) <br />NEMA 3R JUNCTION BOX <br />849 E McFadden Ave- <br />101119004 & 201826064/29/2024