My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
849 E McFadden Ave Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
M
>
McFadden Ave
>
849 E McFadden Ave Unit# 2
>
849 E McFadden Ave Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2025 8:19:59 AM
Creation date
6/10/2025 8:19:56 AM
Metadata
Fields
Template:
Plan
Permit Number
20182606
101119004
Full Address
849 E McFadden Ave Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PageREVISIONS:Project Name3.520 kW (DC) / 3.202 kW (CEC-AC)PHOTOVOLTAIC SYSTEMMCFADDEN AVE849 E MCFADDEN AVE UNIT 2,SANTA ANA, CA 92707APN: 011-224-15DATE:03/21/2024DRAWN BY:TYContractors Signature:PREMIER BUILDERS & HARDSCAPE INC8832 LA GRAND AVEGARDEN GROVE, CA 92841PHONE: (714) 467-9018LICENSE: #995068/B,C53SIGNAGE06 OF 11 <br />NEC 705.10 - ON MAIN SERVICE PANEL: <br />CAUTION <br />849 E MCFADDEN AVE UNIT 2, SANTA ANA, CA 92707 <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY <br />BE ENERGIZED IN THE OPEN POSITION <br />AC PHOTOVOLTAIC DISCONNECT <br />NEC 690.13, 690.15 - AT J-BOXES, ENCLOSURES, DISTRIBUTION <br />EQUIPMENT, AND AC/DC DISCONNECTS <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDE MAY BE ENERGIZED IN THE <br />OPEN POSITION <br />NEC 690.56 - WITHIN 3FT OF SERVICE DISCONNECT: <br />RAPID SHUTDOWN SWITCH FOR <br />SOLAR PV SYSTEM <br />(690.56(C) RED WITH WHITE LETTERING) <br />WARNING <br />POWER SOURCE OUTPUT CONNECTION <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN PV <br />SYSTEM AND REDUCE SHOCK <br />HAZARD IN ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />(690.56(C)(1)(a) YELLOW WITH BLACK LETTERING) <br />NEC 690.56 - ON RAPID SHUTDOWN DISCONNECT: <br />OUTPUT CURRENT: <br />OPERATING VOLTAGE:240V <br />9.7A <br />NEC 690.54 - ON AC DISCONNECT: <br />WARNING <br />THIS EQUIPMENT FED BY MULTIPLE <br />SOURCES. TOTAL RATING OF ALL <br />OVERCURRENT DEVICES, EXCLUDING MAIN <br />SUPPLY OVERCURRENT DEVICE, SHALL <br />NOT EXCEED AMPACITY OF BUSBAR <br />ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF CALIFORNIA <br />ELECTRICAL CODE WILL BE INSTALLED AS REQUIRED. <br />ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC, ENGRAVED, <br />OR MACHINE PRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE. THIS <br />PLAQUE WILL BE ATTACHED BY POP RIVETS OR SCREWS OR OTHER APPROVED <br />METHOD. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. <br />PHOTOVOLTAIC DC CONDUCTORS SHALL BE LABELED, "WARNING PHOTOVOLTAIC DC <br />POWER SOURCE" OR EQUIVALENT EVERY 10 FT AND KEPT MINIMUM 18" BELOW THE <br />ROOF SURFACE. PV DC CIRCUIT LABELS SHALL APPEAR ON EVERY SECTION OF THE <br />WIRING SYSTEM THAT IS SEPARTED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, <br />OR FLOORS. PV DC LABELS SHALL BE REFLECTIVE, SUITABLE FOR SURROUNDING <br />ENVIRONMENT, AND WHITE LETTERING ON A RED BACKGROUND. [690.31(G)] <br />EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, <br />EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN <br />ACCORDANCE WITH 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE. <br />EACH MODULE SHALL BE GROUNDED USING THE SUPPLIED CONNECTION POINT <br />IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTRUCTIONS. <br />IF THE EXISTING GROUNDING ELECTRODE SYSTEM CANNOT BE VERIFIED OR IS ONLY <br />METALLIC WATER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A <br />SUPPLEMENTAL GROUNDING ELECTRODE. <br />EQUIPMENT COMPLIES WITH RAPID SHUTDOWN REQUIREMENTS. [690.12] <br />PLAQUES SHALL BE PLASTIC ENGRAVED IN A CONTRASTING COLOR TO THE PLAQUE. <br />NEC 705.10(C) - <br />AT EACH SERVICE EQUIPMENT: <br />CAUTION <br />MULTIPLE SOURCES <br />OF POWER <br />SOURCES INCLUDE: <br />UTILITY, PV SOLAR <br />MULTIPLE SOURCES <br />OF POWER <br />DISCONNECTS LOCATED AS SHOWN <br />NEC 705.12(B)(3)(2) - BY BREAKER AT DISTRIBUTION EQUIPMENT: <br />NEC 705.12(B)(3)(3) - BY BREAKER AT DISTRIBUTION EQUIPMENT:MA/CD.PVLCMSPNENPHASE AC <br />COMBINER BOX <br />PV SYSTEM DISCONNECT <br />FOR UTILITY OPERATION <br />MAIN ELECTRIC <br />SERVICE DISCONNECT <br />849 E McFadden Ave- <br />101119004 & 201826064/29/2024
The URL can be used to link to this page
Your browser does not support the video tag.