Laserfiche WebLink
24"x30" <br />ACCESS <br />GARBAGE <br />DISPOSAL <br />PROPOSED ADU ELECTRICAL PLAN <br />SCALE: 1/4" = 1' <br />RECESSED LIGHT <br />LIGHT SWITCHES / FIXTURES <br />OUTLETS <br />CARBON MONOXIDE DETECTOR <br />SMOKE DETECTOR <br />EXTERIOR LIGHT <br />WEATHER PROTECTED GROUND- <br />FAULT CIRCUIT INTERUPTER <br />E <br />UTILITY LEGEND <br />EXHAUST FAN <br />CEILING FAN <br />VANITY LIGHT <br />WHOLE HOUSE FAN <br />(2,200 CFM PER T24) <br />MOTION ACTIVATED LIGHT <br />HOSE BIBB (HB) <br />INDOOR AIR QUALITY <br />EXHAUST FAN (MIN. 60 CFM, <br />1 SONE MAX) <br />1.A 120 V ELECTRICAL RECEPTACLE THAT IS WITHIN 3 FEET FROM THE WATER HEATER. <br />2.A CATEGORY III OR IV VENT, OR A TYPE B VENT WITH STRAIGHT PIPE. <br />3.CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE FINISH SURFACE BELOW. <br />4.A GAS SUPPLY LINE WITH AVAILABLE CAPACITY FOR NOT LESS THAN 200,000 BTU/HR SYSTEM. <br />ELECTRICAL NOTES: <br />1.OUTDOOR RECEPTACLES SHALL BE LISTED AS WEATHER RESISTANT, PER SECTION 406.9(B)(1) <br />2.A MINIMUM OF (1) 20 AMPS CIRCUIT FOR THE BATHROOM(S) OUTLET. SUCH CIRCUIT SHALL HAVE NO <br />OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM. PER CEC 210-23(a). <br />3.PROVIDE A MINIMUM OF 2-20 AMP SMALL APPLIANCE CIRCUITS FOR THE KITCHEN COUNTERTOPS. <br />SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE BALANCED. PER CEC 210-52(B) (2). <br />4.PROVIDE A MINIMUM OF 1-20 AMP LAUNDRY BRANCH CIRCUIT. SUCH CIRCUIT SHALL HAVE NO OTHER <br />OUTLETS CEC 210-23(a). <br />5.ALL RECEPTACLES LISTED IN SECTION 210-52 SHALL BE LISTED AS TAMPER-RESISTANT FOR ALL 15 <br />AND 20 AMPERE RECEPTACLES IN DWELLING UNIT FAMILY, DINING, LIVING, PARLORS, LIBRARIES, <br />DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS <br />AND AREAS PER CEC sec 406-12 <br />6.ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMP BRANCH CIRCUITS IN KITCHEN, FAMILY ROOMS, DINING <br />ROOMS, LIVING ROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR <br />ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER, <br />COMBINATION-TYPE. (CEC 210.12). KITCHEN COUNTER-TOPS & LAUNDRY AREAS SHALL BE AFCI/GFCI <br />PROTECTED. <br />7.IN BATH ROOM AT LEAST ONE LUMINARIES IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A <br />VACANCY SENSOR [150.0(K)2J] <br />8.ALL RECESSED DOWNLIGHT LUMINARIES IN CEILING MUST BE IC RATED, AIRTIGHT WITH AIR LEAKAGE <br />LESS THAN 2.0CFM AT 75 PASCALS, ARE SEALED. [150.0(K)1C] <br />9.WHERE MORE THAN ONE CARBON MONOXIDE ALARM IS REQUIRED TO BE INSTALLED WITHIN THE <br />DWELLING UNIT OR WITHIN A SLEEPING UNIT, THE ALARM SHALL BE INTERCONNECTED IN A MANNER <br />THAT ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. <br />10.PROVIDE A 20 AMP GFCI PROTECTED ELECTRICAL OUTLET WITHIN 36” OF THE OUTSIDE EDGE OF <br />EACH BATHROOM SINK BASIN. OUTLET SHALL BE LOCATED ON A WALL OR PARTITION THAT IS <br />ADJACENT TO THE BASIN OR INSTALLED ON THE SIDE OR FACE OF THE BASIN CABINET NOT MORE <br />THAN 12” BELOW THE COUNTERTOP. <br />11.NO PENDANT LIGHT FIXTURES IN ZONE 3 FT AWAY AND 8 FT ABOVE THE BATHTUB OR SHOWER. <br />12.LUMINARIES LOCATED WITHIN THE ACTUAL OUTSIDE DIMENSIONS OF THE TUB OR SHOWER, UP TO <br />8 FEET VERTICALLY FROM THE TOP OF THE BATHTUB RIM OR SHOWER THRESHOLD, SHALL BE <br />MARKED AS SUITABLE FOR DAMP LOCATIONS, PROVIDED WITH A SOLID LENS AND BE GFCI <br />PROTECTED. <br />WATER HEATER LOCATIONS SHALL HAVE: <br />19.ENERGY STORAGE SYSTEM (ESS) READY: <br />A. AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED: <br />I. ESS READY INTERCONNECTION EQUIPMENT [AUTO TRANSFER SWITCH AND PANEL] WITH A <br />MINIMUM BACKED-UP CAPACITY OF 60 AMPS AND A MINIMUM OF FOUR ESS-SUPPLIED BRANCH CIRCUITS, <br />OR <br />II. A DEDICATED, MINIMUM 1" RACEWAY FROM THE MAIN SERVICE TO A SUBPANEL THAT SUPPLIES <br />THE BRANCH CIRCUITS IN SECTION 150.0(S)(2). <br />B. A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE SUPPLIED BY THE ESS: THE REFRIGERATOR, ONE <br />LIGHTING CIRCUIT SHALL BE LOCATED NEAR THE PRIMARY EGRESS, AND AT LEAST ONE CIRCUIT SHALL <br />SUPPLY A SLEEPING ROOM RECEPTACLE OUTLET. <br />C. THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING OF 225 AMPERES WITH SPACE TO <br />INSTALL FUTURE ISOLATION EQUIPMENT/TRANSFER SWITCH WITHIN 3 FEET. <br />HEAT PUMP SPACE HEATER (FURNACE) READY: SYSTEM USING GAS FURNACE TO SERVE INDIVIDT <br />DWELLING UNITS SHALL INCLUDE A DEDICATED 240 VOLT, MINIMUM 30 AMPS BRANCH CIRCUIT WIRI <br />SHALL BE INSTALLED WITHIN 3-FT FROM THE FURNACE FOR A FUTURE HEAT PUMP SPACE HEA <br />INSTALLATION. <br />ELECTRIC COOKTOP READY: SYSTEM USING GAS TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLU <br />THE FOLLOWING SHALL INCLUDE A DEDICATED 240 VOLT, MINIMUM 50 AMPS CIRCUIT WIRING SHALL <br />INSTALLED WITHIN 3-FT FROM THE COOKTOP FOR A FUTURE ELECTRIC COOKTOP INSTALLATION. <br />13.BATHROOM LIGHTING SHALL BE HIGH EFFICACY LUMINARIES (40 LUMENS PER WATT) OR <br />CONTROLLED BY A VACANCY (OCCUPANCY) SENSOR CERTIFIED TO COMPLY WITH SEC 119(D) CEES. THIS <br />IS A MANUAL ON, AUTO-OFF DEVICE. AUTOMATIC ON OR DEVICES WITH AN OVERRIDE SWITCH POSITION <br />ARE NOT APPROVED. HIGH EFFICACY, INCANDESCENT LIGHTING OR FANS ARE REQUIRED TO BE <br />SWITCHED SEPARATELY. <br />14.OVER RANGE EXHAUST SHALL COMPLY WITH ASHRAE 62.2(c) AND CRC 504. <br />15.ALL LIGHTS ARE HIGH EFFICACY WITH NO EXCEPTIONS. IN HABITABLE ROOMS, ALL LIGHTING SHALL <br />BE CONTROLLED BY EITHER DIMMERS OR VACANCY SENSORS. <br />16.ALL RECEPTACLES REQUIRED GFCI SHALL BE COMBINATION OF AFCI, GFCI (CEC 210.52(E)(1)). <br />17.OUTDOOR LIGHTING. ALL LUMINAIRES MOUNTED TO THE BUILDING OR TO OTHER BUILDINGS ON <br />THE SAME LOT SHALL BE HIGH EFFICACY LUMINAIRES AND SHALL BE CONTROLLED BY A <br />PHOTOCONTROL/MOTION SENSOR COMBINATION (WITH OVERRIDE). SEE 150(k)3 FOR REQUIREMENTS. <br />18.PROVIDE UFER OR OTHER APPROVED GROUND PER CEC 250. <br />WHWDWD <br />BALLARDS <br />(N) A/C <br />CONDENSER <br />(N) 200 AMP <br />ELEC. PANEL <br />HOOD VENT OUTSIDE <br />250 CFM HOOD OVER <br />NATURAL GAS RANGE <br />GAS OUTLETAC MINISPLITAC MINISPLITAC MINISPLITAC MINISPLITAC MINI SPLIT <br />VS <br />VS <br />VS <br />VACANCY LIGHT SWITCHES <br />ELECTRIC CLOTHES DRYER <br />READY (CEC150.0(v)) -CLOTHES <br />DRYER USING GAS TO SERVE <br />INDIVIDUAL DWELLING UNITS <br />SHALL INCLUDE A DEDICATED 240 <br />VOLT, MINIMUM 30 AMPS BRANCH <br />CIRCUIT WIRING SHALL BE <br />INSTALLED 3FT FROM THE <br />CLOTHES DRYER LOCATION FOR <br />FUTURE ELECTRIC CLOTHES <br />DRYER LOCATION <br />SEE WATER HEATER <br />NOTE #5 <br />5. WATER HEATING SYSTEM (CEC150.0(n)) <br />A. SYSTEMS USING GAS OR PROPANE WATER HEATERS TO SERVE INDIVIDUAL DWELLING UNITS SHALL <br />DESIGNATE A SPACE AT LEAST 2.5 FEET BY 2.5 FEET WIDE AND 7 FEET TALL SUITABLE FOR THE FUTURE <br />INSTALLATION OF A HEAT PUMP WATER HEATER <br />I. IF THE DESIGNATED SPACE IS WITHIN 3 FEET FROM THE WATER HEATER: <br />1.A DEDICATED 125 VOLT, 20 AMP ELECTRICAL RECEPTACLE THAT IS CONNECTED TO THE ELECTRIC <br />PANEL WITH A 120/240 VOLT 3 CONDUCTOR, 10 AWG COPPER BRANCH CIRCUIT, WITHIN 3 FEET FROM <br />THE WATER HEATER. <br />2.ISOLATE BOTH ENDS OF THE UNUSED CONDUCTOR. <br />3.A RESERVED SINGLE POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL PANEL ADJACENT TO THE <br />CIRCUIT BREAKER <br />4.A CONDENSATE DRAIN THAT ALLOWS NATURAL DRAINING OF THE WATER HEATER. <br />II.IF THE DESIGNATED SPACE IS MORE THAN 3 FEET FROM THE WATER HEATER: SEE <br />ADDITIONAL CODE REQUIREMENTS. <br />ELECTRIC COOKTOP READY <br />(CEC150.0(U))- SYSTEM USING GAS <br />TO SERVE INDIVIDUAL DWELLING <br />UNITS SHALL INCLUDE THE <br />FOLLOWING SHALL INCLUDE A <br />DEDICATED 240 VOLT, MINIMUM 50 <br />AMPS CIRCUIT WIRING SHALL BE <br />INSTALLED WITHIN 3-FT FROM THE <br />COOKTOP FOR A FUTURE ELECTRIC <br />COOKTOP INSTALLATION. <br />DELTA <br />CONSTRUCTION CO. <br />SHEET NUMBER <br />ORIGIN DATE: 06/19/2024 <br />DRAWN BY:LD <br />CHECKED BY:EE <br />DINH VU NGODINH <br />NEW DETACHED ADU <br />906 S VIRLEE ST & <br />906 S VIRLEE ST UNIT #2, <br />SANTA ANA, CA 92704 <br />714-200-8872 <br />17266 FLAME TREE CIR, FOUNTAIN <br />VALLEY, CA 92708 <br />VNDINH2003@GMAIL.COM <br />DRAWINGS APPROVED BY:A4 <br />ADU ELECTRICAL <br />PLAN <br />906 S Virlee St & #2 - <br />10111904212/9/2024