Laserfiche WebLink
Establishment NameGRID COFFEE Inspection Date12/17/2024 <br />Establishment Address3380 S BRISTOL ST SANTA ANA CA 92704 Permit NumberSR155370 <br />Iterative - Violationscurb or base mounted equipment, e.g., storage cabinet, display refrigerators, etc. All floor sinks must be at least half-exposed under the curb <br />mounted equipment, or be in line with the front face of elevated freestanding equipment, and located within 15 feet of the condensate producing <br />equipment. Drain lines must be at least six (6) inches off the floor and 1/2 inch away from walls and not cross any aisle, traffic area or door <br />opening. Provide easily removable (without the use of tools) safety grates on exposed floor sinks. <br />EQUIPMENT SPECIFICATIONS: <br />o All new and replacement food-related or utensil-related equipment shall be certified or classified for SANITATION by an American National <br />Standards Institute (ANSI) accredited certification program. Example of these accredited programs include NSF, UL, Intertek ETL, CSA etc. <br />o All new and replacement electrical appliances shall meet applicable Underwriters Laboratories (UL) standards for electrical equipment as <br />determined by an ANSI accredited certification program. <br />EQUIPMENT INSTALLATION: <br />o All equipment, including shelving, must be supported by six (6) inch high easily cleanable legs, commercial casters, or completely sealed in <br />position on a four (4) inch high continuously coved base or concrete curb. Cooking equipment must be spaced six (6) inches apart and from <br />adjacent walls, or flashed together and to the walls, or, the cooking equipment must be equipped with commercial casters and quick disconnect <br />gas lines. <br />o Food-contact equipment that cannot be broken down for easy cleaning in the utensil sink, must be provided with clean-in-place facilities. The <br />minimum requirements for clean-in-place facilities are: <br />• Hot (minimum 120 °F) and cold water dispensed from a mixing faucet. <br />• Food grade hoses. Hoses must have an approved backflow prevention device. <br />• The wastewater must be drained by indirect connection to an approved sewer line. (i.e., trench drain). <br />WATER HEATER <br />o Provide a water heater with a minimum energy input of 11.5 KW simultaneously wired. <br />o Install the water heater on a four (4) inch high, coved platform or curb, or on at least six (6) inch high, smooth, easily cleanable legs. <br /> <br />FACILITY ENCLOSURE: <br />o All food display, preparation and storage must occur within a fully enclosed food facility or approved food compartment. Enclosed food <br />facilities must be constructed and maintained to prevent the intrusion of vermin, such as flies and rodents. When fully enclosed, no gaps exist <br />greater than 1/4 inch. Doors to the exterior must be self-closing. <br />AIR CURTAINS <br />o Delivery doors shall be equipped with a door-activated air curtain device that delivers an air velocity of at least 750 feet per minute, measured <br />three (3) feet above the floor. The curtain of air shall cover the entire width of the door. For delivery doors that are wider than four (4) feet, the air <br />curtain must produce an air velocity of at least 1600 feet per minute, as measured three (3) feet above the floor. <br />o Air curtains are not to be used in lieu of facility enclosure. <br />EMPLOYEE LOCKERS: <br />o Lockers must be installed on six (6) inch high, easily cleanable legs, cantilevered off the wall, or on a minimum four (4) inch high continuously <br />coved curb or platform. L-angle legs are not acceptable. Within the designated area, you must provide one locker (12" wide x 12" deep x 12" high <br />minimum) per employee on each shift. <br />STORAGE SHELVING: <br />o Provide a minimum of 32 linear feet of shelving, or the equivalent 96 running feet of shelving, for unpackaged food facilities. Provide 16 linear <br />feet minimum, or the equivalent 48 running feet of shelving, for liquor bars. <br />o A shelving unit shall be a minimum 18 inches in depth and three (3) tiers high to count as a linear foot. For example, eight (8) shelving units, <br />each of which is four (4) feet long and three tiers high, would equal 32 linear feet of shelving units. All storage shelving must be accessible with 30 <br />inch aisle clearance. When remote storage is proposed, at least half of the required shelving units shall remain in the kitchen/food service area. <br />RESTROOM REQUIREMENTS: <br />3380 S Bristol St <br />1/8/2025