Laserfiche WebLink
IGALVANIZED 212'x 12'x 7 GAGE THICK <br />STEEL STRAP W/4-5/8'0 LAGS - APPROVED CAP <br />, I '-1-, <br />31/2" <br />4'14' <br />POST--- 5-80 NAILS, <br />EACH END451 / 14'x BEAM <br />- y// / 9.X BEAM <br />/ -0- 4'x4' KNEE <br />BRACE2' -0 72 <br />1 I2-1/2' 0 x 5' LONG LAGS SCREWS 1"x6' KNEE <br />/ 0···|EACH END BRACE <br />= - -di- 1(SEE DETAIL 'E') <br />, p <br />4-1 454'POST MINIMUM <br />/h <br />DETAIL "B"DETAIL "B" ALTERNATE <br />STANDOFF 1 Ch <br />ISTAND-OFF -1 ' STAND-OFF <br />APOST/ IBASE- fEDI <br />12' <br />EMBEDI <br />ANCHORS IN k <br />CONCRETE I <br />•1 1 U I. <br />_*-ANCHOR L --r ii i ++1 <br />-29 <br />BOLT <br />31/2' <br />39·iir <br />\ IGALVANIZED <br />LH 12'x12'x7 GAGE <br />IT W/6-98' 0 LAGS <br />- 44 POST <br />DETAIL "C"-4.-- <br />DETAIL "D" <br />NOTES: <br />ALL MATERIALS: LUMBER, HARDWARE, PLYWOOD, ROOFING, ETC. SHALL BE NEW <br />AND BEAR MANUFACTURER'S OR CERTIFIED AGENCY'S GRADE MARK. <br />ALL CONSTRUCTION SHALL CONFORM TO THE CALIFORNIA BUILDING <br />CODE CURRENTLY IN EFFECT. <br />CONCRETE SLAB TO BE MINIMUM 31/2" THICK. <br />POSTS SHALL BE MINIMUM 4'x4'. <br />BOTTOM OF POSTS SHALL BE ONE INCH (1") ABOVE SLAB. <br />ROOF SHEATING SHALL BE: <br />a. 1/2' PLYWOOD, CDX, 5 PLY EXTERIOR GLUE, WITH INDEX 32/16, T&G <br />STRUCTURAL I, WITH 10 d AT 6" O/CAT SUPPORTED ENDS, AND12° O/C ALONG <br />INTERMEDIATE FRAMING MEMBERS, OR <br />b. 17 BOARD SPAN 32°; 2' SOLID T&G SPAN 8'-0°; 25<2° SELF-SPACED SPAN 6'-0". <br />ROOFING SHALL BE MIN. CLASS °C' ROOF COVERING (CBC TABLE 1505.1) OF: <br />a. WOOD SHAKES: 4/12 PITCH <br />b. WOOD SHINGLES: 3/12 PITCH <br />c. BUICT-UP ROOF SLOPE TO DRAIN (MINIMUM 1/4"/FT.) <br />d. CLAY AND CONCRETE ROOF TILES INSTALLED IN ACCORDANCE WITH <br />MANUFACTURER'S INSTRUCTIONS. <br />MAXIMUM HEIGHT FORA PATIO COVER IS TWELVE FEET. <br />PATIO COVER SHALL BE·USED ONLY FOR RECREATIONAL OUTDOOR LIVING <br />PURPOSE AND NOT AS CARPORT, GARAGE, STORAGE ROOM OR HABITABLE ROOM. <br />1. ENCLOSURE WALLS MAY HAVE ANY CONFIGURATION, PROVIDED THE OPEN AREA <br />OF THE LONGER WALLAND ONE ADDITIONAL WALL IS EQUALTO AT LEAST SIXTY- <br />FIVE PERCENT·QF THE AREA BELOW A MINIMUM'OF 6'-8" OF EACH WALL, <br />MEASURED FROM THE FLOOR. <br />. OPENINGS MAY BE ENCLOSED WITH INSECTSCREENING OR PLASTIC THAT IS <br />REAbILY REMOVABLE, TRANSLUCENT, OR TRANSPARENT PLASTIC NOT MORE THAN <br />1/8 INCH IN THICKNESS. <br />. EMERGENCY EGRESS OR RESCUE WINDOWS FROM SLEEPING ROOMS MAY OPEN <br />INTO AN AREA OF AN UNENCLOSED PATIO COVER. <br />. PATIO COVER MUST BE AT LEAST 5 FEET FROM PROPERTY LINES. <br />-4- <br />- 44*4' KNEE BRACE <br />l <br />r 2-1/2' 0 x5" LONG LAG SCREWS <br />-0-0- <br />1-1- <br />E- 4'x POST <br />-4-- <br />DETAIL "E" <br />0 <br />PERSON RESPONSIBLE FOR DESIGN AND CONSTRUCTION OF PATIO COVER: <br />Leone / CA_-ms <br />PRINT NAME <br />1-tone' C discts <br />SIGNATURE <br />10 )22)13 <br />DATE <br />rev: 07/19/2011 1•Page 2 of 2