SHEET INDEXGENERAL NOTES <br />SN1 GENERAL NOTES <br />SN2 TYPICAL DETAILS <br />S-1 DECK AND ROOF FRAMING PLANS <br />RISK CATEGORY II SS = 1.282 R = 6.5 <br />IMPORTANCE FACTOR 1.0 S1 = 0.460 <br />SEISMIC DESIGN CATEGORY D SDS = 1.025 <br />SITE CLASS D SD1 = N/A <br />BASIC SEISMIC FORCE RESISTING SYSTEM - LIGHT FRAMED WALLS SHEATHED w/ WOOD <br />STRUCTURAL PANELS <br />ANALYSIS PROCEDURE USED - EQUIVALENT LATERAL FORCE PROCEDURE <br />15/32" APA RATED SHEATHING, EXPOSURE 1 WITH A MIN. PANEL INDEX OF 32/16 <br /> BOUNDARY NAILING (B.N.)8d COMMON NAILS AT 6"o/c <br /> EDGE NAILING (E.N.)8d COMMON NAILS AT 6"o/c <br /> FIELD NAILING (F.N.)8d COMMON NAILS AT 12"o/c <br />23/32" APA RATED STURD-I-FLOOR, T&G, EXPOSURE 1 WITH A MIN. SPAN RATING OF 24". <br />PLYWOOD MUST CONFORM WITH DOC PS1 OR PS2. <br /> BOUNDARY NAILING (B.N.)10d COMMON NAILS AT 6"o/c <br /> EDGE NAILING (E.N.)10d COMMON NAILS AT 6"o/c <br /> FIELD NAILING (F.N.)10d COMMON NAILS AT 12"o/c <br />USE RING OR SCREW SHANK NAILS AND GLUE SHEATHING TO FRAMING WITH <br />ADHESIVES MEETING APA SPECIFICATION AFG-01 OR ASTM D3498. APPLY GLUE IN <br />ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS. <br />GENERAL REQUIREMENTS <br />1.WORK PERFORMED SHALL COMPLY WITH THE 2022 CBC AND ALL APPLICABLE LOCAL, STATE <br />AND FEDERAL CODES, ORDINANCES, LAWS, REGULATIONS AND PROTECTIVE COVENANTS <br />GOVERNING THE SITE OF WORK. <br />2.STANDARD SPECIFICATIONS OF ASTM ARE NOTED HEREIN AND AS REQUIRED BY THE <br />BUILDING CODE. <br />3.ALL WORK NEEDS TO BE PERFORMED BY QUALIFIED AND EXPERIENCED CONTRACTORS <br />FAMILIAR WITH THIS TYPE OF PROJECT. <br />4.IN CASE OF CONFLICT, THE MORE STRINGENT REQUIREMENT SHALL GOVERN. <br />5.THE ENGINEER OR ARCHITECT OF RECORD MUST BE NOTIFIED IMMEDIATELY SHOULD ANY <br />QUESTION ARISE OR ANY DISCREPANCY BE FOUND PERTAINING TO THE WORKING <br />DRAWINGS. <br />6.ON-SITE VERIFICATION OF ALL DIMENSIONS AND CONDITIONS IS THE RESPONSIBILITY OF <br />THE CONTRACTORS AND SUB-CONTRACTORS. NOTED DIMENSIONS TAKE PRECEDENCE <br />OVER THE SCALE OF DRAWINGS. <br />7.NO DEVIATIONS FROM THESE PLANS SHALL BE MADE WITHOUT THE WRITTEN CONSENT OF <br />JJS STRUCTURAL, INC. <br />8.THE DESIGN, ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY <br />SUPPORT, ETC. IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. IT HAS NOT BEEN <br />CONSIDERED BY THE ARCHITECT OR ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR THE <br />STABILITY OF THE STRUCTURE PRIOR TO THE APPLICATION OF ALL SHEAR WALLS, ROOF AND <br />FLOOR DIAPHRAGMS AND FINISH MATERIALS. THE BUILDER HAS CONTRACTED WITH JJS <br />STRUCTURAL, INC. FOR THE LIMITED SERVICES OF PROVIDING THE MINIMUM STRUCTURAL <br />ENGINEERING DRAWINGS REQUIRED, WHEN COMBINED WITH THE OTHER BUILDING <br />CONSULTANTS DRAWINGS TO OBTAIN A BUILDING PERMIT FOR THIS PROJECT. <br />9.THE BUILDER HAS REQUESTED, ACCEPTS AND REPRESENTS THAT HE WILL SELECT ALL <br />MATERIALS AND MANUFACTURERS, QUALIFY AND SELECT ALL INSTALLERS, DIRECT ALL WAYS <br />AND MEANS OF CONSTRUCTION AND PROVIDE ALL SUB-CONTRACTORS ADDITIONAL <br />INFORMATION, ABOVE AND BEYOND THESE DRAWINGS, REQUIRED TO COMPLETE THE <br />PROJECT IN CONFORMANCE WITH ALL GOVERNING AGENCIES AND THE WORK WILL MEET <br />OR EXCEED ACCEPTED INDUSTRY STANDARDS. <br />DESIGN CRITERIA <br />1.GRAVITY LOADS: <br />1.1.EX'G ROOF TILE ASSUMED TO BE CONCRETE (WEIGHT = 10.0psf, MAX) <br />1.2.EX'G DECK ASSUMED TO HAVE DEX-O-TEX, OVER 3 4" SHT'G, OVER 2x6 DECKING <br />(WEIGHT = 8.4psf, MAX.) <br />2.SEISMIC DESIGN PARAMETERS <br />3.WIND DESIGN PARAMETERS <br />4.LUMBER GRADES: <br />5.ROOF SHEATHING: <br />6.FLOOR SHEATHING <br />REINFORCED CONCRETE <br />1.ALL REINFORCED CONCRETE MATERIALS AND CONSTRUCTION SHALL CONFORM TO CBC <br />CHAPTER 19. <br />2.CEMENT AND CONCRETE AGGREGATES SHALL CONFORM TO CBC SECTION 1903. <br />3.ADMIXTURES CONTAINING CALCIUM CHLORIDES SHALL NOT BE USED. <br />4.CONCRETE SHALL BE TO THE STRENGTH AND SLUMP SPECIFIED AND CONSIST OF PORTLAND <br />CEMENT ASTM C-150. AGGREGATES MUST CONFORM TO ASTM C-33 AND WATER MUST BE <br />CLEAN AND POTABLE. <br />5.THE MINIMUM COMPRESSIVE STRENGTH (f'c) OF CONCRETE SHALL BE 2500 psi AT 28 DAYS, <br />U.N.O. <br />5.1.THE MINIMUM COMPRESSIVE STRENGTH (f'c) OF CONCRETE SHALL BE 3000 psi AT 28 <br />DAYS IF STRUCTURE IS OVER TWO-STORIES IN HEIGHT <br />6.TYPE V CEMENT w/ A MAX. W:C RATIO OF 0.45 MUST BE USED IF SOIL CONTAINS SULFATE, <br />PER CBC SECTION 1904 & ACI 318-14, TABLE 19.3.2.1. MIN. f'c = 4500 psi AT 28 DAYS. SPECIAL <br />INSPECTION IS NOT REQUIRED. REFER TO CBC SECTION 1904, SOILS AND CORROSION <br />ENGINEERS RECOMMENDATIONS FOR CONCRETE EXPOSED TO CORROSIVE ELEMENTS. <br />7.SPECIAL INSPECTION IS REQUIRED FOR CONCRETE w/ f'c > 2500 psi UNLESS IT'S SOLELY USED <br />FOR ITEM 6 ABOVE. <br />8.REINFORCING STEEL SHALL CONFORM TO ASTM A615. GRADE 40 FOR SIZES #3 & #4 AND <br />GRADE 60 FOR SIZES #5 & LARGER. <br />9.ALL REINFORCING STEEL, DOWELS, HOLDOWNS AND OTHER INSERTS MUST BE SECURED IN <br />PLACE AND APPROVED BY THE BUILDING OFFICIAL PRIOR TO CONCRETE BEING POURED. <br />10.MIN. CONCRETE COVER FOR REINFORCING IS AS FOLLOWS: <br />10.1.CONC. PLACED AGAINST EARTH, NOT FORMED 3" <br />10.2.CONCRETE FORMED OR TROWELED 2" <br />10.3.WALLS AND CURBS 1-1/2" <br />10.4.SLABS ON GRADE AT CENTER <br />ROOF LOADS DECK LOADS <br />DEAD LOAD 18 psf 13 psf <br />LIVE LOAD 20 psf 60 psf <br />TOTAL LOAD 38 psf 73 psf <br /> 2x AND 4x MEMBERS DFL #2 <br /> 6x AND 8x MEMBERS DFL #1 <br /> STUDS (9'-0" IN HT. OR LESS)DFL STUD GRADE <br /> STUDS (TALLER THAN 9'-0")DFL #2 <br /> TOP AND SILL PLATES DFL #2 OR BETTER* <br />*MUD SILLS IN CONTACT WITH CONCRETE ARE TO BE PRESSURE TREATED <br />FOUNDATION <br />1.ALL CONTINUOUS FOOTINGS MUST HAVE 5/8" Ø. x MIN. 12" ANCHOR BOLTS EMBEDDED 7" <br />INTO CONCRETE AND SPACED NO MORE THAN 48"o/c, U.N.O. ONE ANCHOR BOLT MUST <br />BE LOCATED BETWEEN 4" & 12" FROM THE END OF ALL SILL PLATES AND THERE MUST BE AT <br />LEAST (2) ANCHOR BOLTS PER SILL PLATE / SHEAR WALL. <br />2.ANCHOR BOLTS AT SHEAR WALLS MUST HAVE A 3"x3"x0.229" THK. PLATE WASHER <br />INSTALLED BETWEEN THE NUT AND SILL PLATE. <br />2.1.THE HOLE IN THE PLATE WASHER IS PERMITTED TO BE DIAGONALLY SLOTTED w/ A <br />WIDTH OF UP TO 3 16" LARGER THAN THE BOLT DIAMETER AND A SLOT LENGTH NOT TO <br />EXCEED 13 4", PROVIDED A STD. CUT WASHER IS PLACED BETWEEN THE PLATE WASHER <br />AND NUT. <br />3.INTERIOR NON-SHEAR WALLS SHALL BE ANCHORED TO THE CONCRETE SLAB WITH <br />SIMPSON PHNW SERIES 0.145" DIA. SHOT PINS, SPACED AT 16"o/c. PROVIDE MINIMUM <br />114" EMBED. INTO SLAB. REFER TO ICC-ES ESR-2138 FOR INSTALLATION INFORMATION. <br />4.ALL HOLDOWNS MUST BE INSTALLED PER THE LATEST ICC-ES REPORTS AND TIED IN PLACE <br />JUST PRIOR TO FOUNDATION INSPECTION. IT IS THE RESPONSIBILITY OF THE <br />CONTRACTOR TO LOCATE ALL ANCHORS AS DIMENSIONS ARE NOT FURNISHED IN THESE <br />STRUCTURAL PLANS. <br />5.PROVIDE #3 x 24" DOWELS AT 24"o/c ALL CONCRETE STOOPS AND PORCHES. <br />6.IF THERE IS A SOILS ENGINEER ON THE PROJECT, ALL FOOTING, SLAB AND REBAR <br />REQUIREMENTS AS WELL AS EXPANSIVE SOILS REQUIREMENTS MUST BE VERIFIED. THE <br />MORE STRINGENT GUIDELINES SHALL GOVERN. <br />7.CONTRACTOR SHALL DAMPEN SLAB UNDERLAYMENT OF SAND/MEMBRANE JUST PRIOR TO <br />CONCRETE PLACEMENT TO ASSIST IN UNIFORM CONCRETE CURING. SLABS MUST NOT BE <br />POURED DURING OR IMMEDIATELY AFTER RAINSTORMS. THE SPECIFIED SAND OVER <br />VISQUEEN SHOULD NOT BE SATURATED AT THE TIME OF THE CONCRETE POUR. ANY FREE <br />WATER TRAPPED IN THE SAND LAYER MUST BE REMOVED PRIOR TO THE CONCRETE POUR. <br />8.THE BOTTOMS OF FOOTING EXCAVATIONS SHALL BE LEVEL, CLEAN AND FREE OF LOOSE <br />MATERIAL OR WATER WHEN CONCRETE IS PLACED. OVER EXCAVATION SHALL BE FILLED <br />WITH CONCRETE OR PROPERLY COMPACTED FILL THAT HAS BEEN TESTED AND APPROVED <br />BY THE SOILS ENGINEER. BACKFILL SHALL NOT BE PLACED UNTIL SUPPORTING <br />FOUNDATIONS, WALLS AND SLAB HAVE ATTAINED SUFFICIENT STRENGTH TO SUPPORT <br />LATERAL SOIL PRESSURE. <br />9.CONCRETE PLACEMENT SHALL BE MONOLITHIC IN ONE CONTINUOUS OPERATION, <br />UNIFORMLY PLACED, MUST BE VIBRATED AND WELL CONSOLIDATED, U.N.O. FOR <br />NON-MONO POUR, USE #4 DOWELS AT 18"o/c, MIN. 18" INTO SLAB AND 12" INTO 1ST. <br />POUR. <br />10.FLOOR SLAB SHALL BE POURED LEVEL TO 1/8" IN 10'. <br />11.REQUIREMENTS FOR THE SITE AND PAD PREPARATION, PRE-SATURATION OF SUBGRADE <br />SOILS, DAYLIGHT SETBACK OF EXTERIOR FOOTINGS FROM ANY DESCENDING SLOPE SHALL <br />COMPLY WITH THE SOIL ENGINEER'S RECOMMENDATIONS, AS REQUIRED. <br />12.REFER TO THE ARCHITECTURAL DRAWINGS FOR DIMENSIONS, DEPRESSIONS, SLOPE, <br />SHELVES, PATIOS, STOOPS AND PORCHES NOT SHOWN. <br />13.DO NOT WALK ON THE SLAB UNTIL AT LEAST 24 HOURS AFTER THE CONCRETE HAS BEEN <br />POURED. WALL FRAMING MAY COMMENCE 4-5 DAYS AFTER THE CONCRETE POUR AND <br />ROOF/FLOOR FRAMING 7-10 DAYS AFTER. THE ROOF MAY NOT BE LOADED UNTIL AT LEAST <br />14 DAYS AFTER THE CONCRETE HAS BEEN POURED. <br />14.NO PIPES OR CONDUITS SHALL EXTEND UNDER ISOLATED COLUMN FOOTINGS OR UNDER <br />CONTINUOUS WALL FOOTINGS UNLESS SPECIFICALLY DETAILED OR APPROVED BY JJS <br />STRUCTURAL, INC. AND THE BUILDING OFFICIAL. <br />15.SHEAR WALL ANCHOR BOLTS AND HOLDOWN HARDWARE MUST BE SECURED IN PLACE <br />PRIOR TO FOUNDATION INSPECTION. <br />16.FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE TREATED WOOD, <br />CONFORMING TO AWPA U1 AND M4. <br />17.ALL BOLTS IN CONCRETE MUST CONFORM TO ASTM F1554, GRADE 36, U.N.O. <br />18.ALL HIGH STRENGTH BOLTS MUST CONFORM TO ASTM A449 (UP TO 1"Ø) AND ASTM A193 <br />B7 OR ASTM F1554 GRADE 105 (118" & 114"Ø). <br />FRAMING <br />1.ALL STRUCTURAL WOOD SHALL BE OF DOUGLAS FIR LARCH SPECIES WITH A MAXIMUM <br />MOISTURE CONTENT OF 19% AT THE TIME OF CONSTRUCTION. WOOD SHALL CONFORM <br />WITH DOC PS20. <br />2.CONVENTIONAL CONSTRUCTION REQUIREMENTS OF CHAPTER 23 FOR LIGHT FRAMED <br />CONSTRUCTION SHALL BE FOLLOWED AS REQUIRED. <br />3.ALL FRAMING, BRACING, NAILING, NOTCHING, DRILLING OR BORING SHALL BE IN <br />ACCORDANCE WITH THE BUILDING CODE UNLESS MORE STRINGENT REQUIREMENTS ARE <br />REQUIRED BY THE LOCAL JURISDICTION. <br />4.TOP PLATES OF ALL WOOD STUDS WALLS MUST CONSIST OF (2) 2x MEMBERS THE SAME <br />WIDTH AS THE STUDS, U.N.O. TOP PLATES SHALL LAP A MINIMUM OF 48" AND BE SPLICED <br />WITH A MINIMUM OF (8) 16d NAILS, SPACED AT 12"o/c, MAX. <br />5.ALL SHEAR PANELS MUST HAVE CONTINUOUS SHEATHING FROM ONE END TO THE OTHER <br />AND FROM PLATE TO PLATE. <br />6.NON-BEARING WALLS ARE TO BE FRAMED WITH 2x4 STUDS AT 24"o/c FOR A MAXIMUM <br />HEIGHT OF 14'-0" AND 2x6 STUDS AT 24"o/c FOR A MAXIMUM HEIGHT OF 20'-0". TALLER <br />WALLS AND BEARING WALLS WILL BE DESIGNED ON A CASE BY CASE BASIS (SECTION <br />2308.5.1). <br />7.NON-BEARING HEADERS: USE 2x4 FOR A MAXIMUM OPENING WIDTH OF 3'-0", 2-2x4 FOR <br />AN OPENING WIDTH OF 6'-0', MAX. AND 4x6 FOR OPENINGS UP TO 12'-0" WIDE. <br />8.2x DFL #2 CEILING JOISTS MAY BE USED TO SUPPORT NO MORE THAN 6 PSF DEAD <br /> LOAD AND 10 PSF LIVE LOAD AS FOLLOWS: <br />2x4'S AT 16"o/c - MAX. SPAN = 9'-0" <br />2x6'S AT 16"o/c - MAX. SPAN = 13'-0" <br />2x8'S AT 16"o/c - MAX. SPAN = 14'-6" <br />2x10'S AT 16"o/c - MAX. SPAN = 15'-9" <br />THIS IS BASED ON A DRYWALL CEILING AND A MAXIMUM DEFLECTION OF <br />L/240. <br />9.ALL NAILS SHALL BE SINKER NAILS AND STAGGERED EXCEPT AS SPECIFIED IN CBC <br /> TABLE 2304.10.2, U.N.O. <br />10.FASTENERS, INCLUDING NUTS , WASHERS & CONNECTORS IN CONTACT w/ PRESERVATIVE <br />TREATED OR FIRE RETARDANT TREATED WOOD SHALL BE OF HOT-DIPPED ZINC-COATED <br />GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. THE COATING <br />WEIGHTS FOR ZINC COATED FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A153. <br />11.ALL MACHINE BOLTS SHALL CONFORM TO ANSI/ASME STANDARD B18.2.1. BOLT HOLES <br />SHALL BE DRILLED 132" - 116" LARGER THAN THE BOLT DIAMETER. <br />12.FOR NON-SHEAR WALL APPLICATIONS, ROUND WASHERS SHALL BE USED ON ALL <br /> BOLTS AND SHALL CONFORM WITH ANSI/ASME STANDARD B18.2.1. USE MIN. 13 8" Ø x 7 64" <br /> THICK WASHER FOR 12"Ø BOLT, 13 4"Ø x 9 64" THICK WASHER FOR 5 8"Ø BOLT AND 212"Ø x 1164" <br /> THICK WASHER FOR 1" Ø BOLT. <br />13.MANUFACTURED HARDWARE SPECIFIED ON THE DRAWINGS ARE TO BE SIMPSON <br /> STRONG TIE OR EQUAL. FOLLOW ALL MANUFACTURERS REQUIREMENTS AND <br /> RECOMMENDATIONS FOR INSTALLATION AND HANDLING OF THE PRODUCT. <br />14.ALL JOIST HANGERS SHALL BE SIMPSON U HANGERS (OR EQUAL) AND ALL BEAM <br /> HANGERS SHALL BE SIMPSON HU HANGERS (OR EQUAL), U.N.O. ON PLANS. FOLLOW <br /> MANUFACTURERS RECOMMENDATIONS FOR INSTALLATION. <br />15.ALL LEDGERS SHALL BE SPLICED WITH AN ST22 STRAP, U.N.O. <br />16.ROOF/FLOOR SHEATHING & SHEAR PANELS MAY BE PLYWOOD OR OSB. REFER TO DESIGN <br />CRITERIA & SHEAR WALL SCHEDULE FOR ADD'L INFORMATION. <br />17.ALL NAILING SHALL CONFORM TO CBC TABLE 2304.10.2 <br />18.ALL WOOD STRUCTURAL PANELS SHALL CONFORM TO DOC PS1 OR DOC PS2 <br />19.WOOD FRAMING MEMBERS (E.G. BEAMS AND POSTS) SHALL BE PRESSURE TREATED WHEN <br />EXPOSED TO WEATHER, PER CBC 2304.12.2.3 <br />CONCRETE MASONRY <br />1.ALL CONCRETE MASONRY MATERIALS & CONSTRUCTION SHALL BE IN ACCORDANCE WITH <br />CHAPTER 21 OF THE CBC. <br />2.MORTAR SHALL CONFORM TO ASTM C 270 TYPE S OR M, PER CBC SECTION 2103.8. <br />3.GROUT SHALL COMPLY WITH ARTICLE 2.2 OF TMS 602 / ACI 530.1 / ASCE 6, PER CBC <br />SECTION 2103.12. A MINIMUM 28-DAY COMPRESSION STRENGTH OF 2000 PSI MUST BE <br />ATTAINED UNLESS THE SPECIFIED MASONRY UNITS REQUIRE A GREATER STRENGTH. <br />4.THE SPECIFIED COMPRESSIVE STRENGTH OF MASONRY, f'm, SHALL BE 1500 PSI, U.N.O. <br />5.REINFORCING STEEL SHALL CONFORM TO ASTM A615. GRADE 40 SHALL BE USED FOR SIZES <br />#3 & #4 AND GRADE 60 FOR SIZES #5 AND LARGER. <br /> STRUCTURAL STEEL <br />1.ALL STRUCTURAL STEEL MATERIALS AND CONSTRUCTION SHALL CONFORM TO CBC <br /> CHAPTER 22. <br />2.ALL STEEL SHALL BE PRIMED w/ A RUST RESISTANT PRIMER AND CONFORM TO ASTM <br /> A36 (Fy=36ksi), U.N.O. <br />2.1.W SHAPES SHALL CONFORM TO ASTM A992 (Fy=50ksi) <br />2.2.RECTANGULAR HSS TUBING SHALL CONFORM TO ASTM A500, GRADE C (Fy=50ksi) <br />2.3.ROUND HSS TUBING SHALL CONFORM TO ASTM A500, GRADE C (Fy=46ksi) <br />2.4.STEEL PIPE SHALL CONFORM TO ASTM A53, GRADE B (Fy=35ksi) <br />3.ALL STRUCTURAL WELDING PROCEDURES AND MATERIALS SHALL CONFORM TO CBC <br /> SECTION 2204.1. ALL WELDING SHALL BE BY THE SHIELDED METAL ARC WELDING <br /> PROCESS OR THE SUBMERGED ARC WELDING PROCESS USING E70XX-LOW <br /> HYDROGEN ELECTRODES, U.N.O. <br />4.ALL BOLTS FOR STEEL MEMBER CONNECTIONS SHALL CONFORM TO CBC SECTION <br /> 2204.2 & ASTM A325N, U.N.O. <br />5.HOLES FOR BOLTS MUST BE DRILLED OR PUNCHED AND SHALL BE 1/16" LARGER THAN <br /> THE BOLT DIAMETER. <br />6.ALL SHOP WELDING AND FABRICATION MUST BE DONE IN A SHOP CERTIFIED BY AISC <br /> QUALITY CERTIFICATION PROGRAM AND APPROVED BY THE BUILDING OFFICIAL. ALL <br /> FIELD WELDING MUST BE PERFORMED BY A CERTIFIED WELDER AND A SPECIAL <br /> INSPECTOR SHALL CONTINUOUSLY INSPECT ALL STRUCTURAL FIELD WELDING. BOTH <br /> SHALL BE APPROVED BY THE BUILDING OFFICIAL. <br />7.WELDING SHALL BE PERFORMED IN ACCORDANCE WITH A WELDING PROCEDURE <br />SPECIFICATION (WPS) AS REQUIRED IN AWS D1.1 AND APPROVED BY THE ENGINEER OF <br />RECORD. SPECIFY THE REQUIRED "WPS" ON THE PLANS. <br />8.ALL FILLER (WELD) METAL SHALL HAVE MINIMUM CVN OF 20 FT-LBS AT -20 DEGREES <br />FAHRENHEIT AND 40 FT-LBS AT 70 DEGREES FAHRENHEIT. <br />9.THE STRUCTURAL STEEL FABRICATOR SHALL SUBMIT SHOP DRAWINGS FOR ALL STEEL <br />MEMBERS TO THE ENGINEER OF RECORD FOR REVIEW. <br /> GLUED LAMINATED LUMBER <br />1.GLUE LAMINATED LUMBER SHALL BE MANUFACTURED, FABRICATED AND SHALL BE <br />INSPECTED FOR QUALITY CONTROL IN ACCORDANCE WITH ANSI/APA-190.1 AND ASTM <br />D3737, STRUCTURAL GLUED - LAMINATED TIMBER. FABRICATION OF TIMBERS SHALL BE <br />USING MATERIALS AT 16% OR LOWER MOISTURE CONTENT AND SHALL UTILIZE ADHESIVE <br />APPROVED FOR WET CONDITION OF SERVICE. <br />2.GLUE LAMINATED TIMBERS SHALL BE VISUALLY GRADED WESTERN SPECIES WITH A 24F-V4 <br />COMBINATION FOR STANDARD APPLICATIONS AND 24F-V8 FOR CANTILEVERED <br />APPLICATIONS. <br />3.GLUE LAMINATED TIMBERS SHALL BE CLEARLY STAMPED OR MARKED AND SHALL BE <br />ACCOMPANIED BY A CERTIFICATE OF COMPLIANCE INDICATING CONFORMANCE TO <br />ANSI/APA-190.1. APPROVED CERTIFICATE OF COMPLIANCE ISSUING AGENCIES ARE THE <br />AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC), WESTERN WOOD PRODUCTS <br />ASSOCIATION (WWPA) OR THE APA - THE ENGINEERED WOOD ASSOCIATION. A COPY OF <br />THE CERTIFICATE OF COMPLIANCE SHALL BE PRESENTED TO THE INSPECTOR PRIOR TO <br />INSTALLATION, WITH COPIES FORWARDED TO THE STRUCTURAL ENGINEER AND <br />ARCHITECT. <br />4.CAMBER REQUIREMENTS SHALL BE AS INDICATED IN THE CONSTRUCTION DOCUMENTS <br />OR SHALL HAVE A STANDARD CAMBER WITH A RADIUS OF CURVATURE OF 3500 FEET PLUS <br />OR MINUS 200 FEET. <br />5.GLUED-LAMINATED TIMBERS EXPOSED TO WEATHER SHALL BE PRESSURE TREATED AND <br />CONFORM TO AMERICAN WOOD PRESERVERS ASSOCIATION (AWPA), AWPA STANDARD <br />C-28, PRESSURE TREATMENT OF STRUCTURAL GLUED-LAMINATED TIMBER OR AITC <br />STANDARD 109, STANDARD PRESERVATIVE TREATMENT OF STRUCTURAL <br />GLUED-LAMINATED TIMBER. AMMONIUM COPPER ZINC ARSENATE SHALL BE USED AS THE <br />TREATMENT SOLUTION. TREATMENT TYPE AND INSPECTION AGENCY SHALL BE CLEARLY <br />STAMPED ON TREATED MATERIAL. TREATMENT AGENCY TO CONFORM TO AMERICAN <br />WOOD PRESERVERS BUREAU (AWPB) AWPB STANDARD LP. EXTERIOR EXPOSED SURFACES <br />SHALL BE COATED OR PAINTED WITH MINIMUM TWO COATS OF SEALER OR COVERED BY <br />FRAMING OR DRYWALL FOR INTERIOR APPLICATIONS. <br />Fastening Schedule (2304.10.2) <br />Description of Building Elements Number & Type of <br />Fastener <br />Spacing & <br />Location <br />Roof <br />1. <br />Blk'g between ceiling joists, rafters or <br />trusses to top plate or other framing below 3-8d common (212"x0.131")Each end, toenail <br />Blk'g between rafters or truss not at the <br />wall top plate, to rafter or truss <br />2-8d common (212"x0.131")Each end, toenail <br />2-16d common (312"x0.162")End nail <br />Flat blk'g to truss and web filler 16d common (312"x0.162")Face nail <br />2.Ceiling joists to top plate 3-8d common (212"x0.131"); or <br />3-10d box (3"x0.128")Face nail <br />3.Ceiling joists not attached to parallel <br />rafter, laps over partitions (no thrust) <br />3-16d common (312"x0.162"); or <br />4-10d box (3"x0.128")Face nail <br />4.Ceiling joist attached to parallel rafter <br />(heel joint)Per plan or Table 2308.7.3.1 Face nail <br />5.Collar tie to rafter 3-10d common (3"x0.148"); or <br />4-10d box (3"x0.128")Face nail <br />6.Rafter or roof truss to top plate <br />3-10d common (3"x0.148"); or <br />3-16d box (312"x0.135"); or <br />4-10d box (3"x0.128") <br />Toenail1 <br />7.Roof rafters to ridge valley or hip rafters; or <br />roof rafter to 2-inch ridge beam <br />2-16d common (312"x0.162"); or <br />3-10d box (3"x0.128")End nail <br />3-10d common (312"x0.148"); or <br />4-16d box (312"x0.135"); or <br />4-10d box (3"x0.128") <br />Toenail <br />Wall <br />8.Stud to stud (not at braced wall panels) <br />16d common (312"x0.162"); or 24"o/c face nail <br />10d box (3"x0.128")16"o/c face nail <br />9. <br />Stud to stud and abutting studs at <br />intersecting wall corners (at braced wall <br />panels) <br />16d common (312"x0.162"); or 16"o/c face nail <br />16d box (312"x0.135")12"o/c face nail <br />10.Built-up header (2" to 2" header) <br />16d common (312"x0.162"); or 16"o/c each edge, <br />face nail <br />16d box (312"x0.135")12"o/c each edge, <br />face nail <br />11.Continuous header to stud 4-8d common (212"x0.131"); or <br />4-10d box (3"x0.128")Toenail <br />12.Top plate to top plate <br />16d common (312"x0.162"); or 16"o/c face nail <br />10d box (3"x0.128")12"o/c face nail <br />13.Top plate to top plate, at end joints 8-16d common (312"x0.162"); or <br />12-10d box (3"x0.128") <br />Each side of end joint, <br />face nail (minimum <br />24" lap splice length <br />each side of end joint) <br />14.Bottom plate to joist, rim joist, band joist or <br />blk'g (not at braced wall panels) <br />16d common (312"x0.162"); or 16"o/c face nail <br />16d box (312"x0.135")12"o/c face nail <br />15.Bottom plate to joist, rim joist, band joist or <br />blk'g at braced wall panels <br />2-16d common (312"x0.162); or <br />3-16d box (312"x0.135")16"o/c face nail <br />16.Stud to top or bottom plate <br />4-8d common (212"x0.131"); or <br />4-10d box (3"x0.128")Toenail <br />2-16d common (312"x0.162"); or <br />3-10d box (3"x0.128")End nail <br />17.Top plates, laps at corners & intersections 2-16d common (312"x0.162"); or <br />3-10d box (3"x0.128")End nail <br />18.1" brace to each stud and plate 2-8d common (212"x0.131"); or <br />2-10d box (3"x0.128")Face nail <br />19.1"x6" sheathing to each bearing 2-8d common (212"x0.131"); or <br />2-10d box (3"x0.128")Face nail <br />20.1"x8" and wider sheathing to each bearing 3-8d common (212"x0.131"); or <br />3-10d box (3"x0.128")Face nail <br />Floor <br />21.Joist to sill, top plate or girder 3-8d common (212"x0.131"); or <br />floor 3-10d box (3"x0.128")Toenail <br />22.Rim joist, band joist, or blk'g to top plate, <br />sill or other framing below <br />8d common (212"x0.131"); or <br />10d box (3"x0.128")6"o/c, toenail <br />23.1"x6" subfloor or less to each joist 2-8d common (212"x0.131"); or <br />2-10d box (3"x0.128")Face nail <br />24.2" subfloor to joist or girder 2-16d common (312"x0.162")Face nail <br />25.2" planks (plank & beam - floor & roof)2-16d common (312"x0.162")Each bearing, face <br />nail <br />26.Built-up girders & beams, 2" lumber layers <br />20d common (4"x0.192") <br />32"o/c, face nail at <br />top & btm staggered <br />on opposite sides <br />10d box (3"x0.128") <br />24"o/c, face nail at <br />top & btm staggered <br />on opposite sides <br />And: <br />2-20d common (4"x0.192"); or <br />3-10d box (3"x0.128") <br />Ends at each splice, <br />face nail <br />27.Ledger strip supporting joists or rafters 3-16d common (312"x0.162"); or <br />4-10d box (3"x0.128") <br />Each joist or rafter, <br />face nail <br />28.Joist to band joist or rim joist 3-16d common (312"x0.162"); or <br />4-10d box (3"x0.128")End nail <br />29.Bridging or blk'g to joist, rafter or truss 2-8d common (212"x0.131"); or <br />2-10d box (3"x0.128")Each end, toenail <br />Notes: <br />1. Where a rafter is fastened to an adjacent parallel ceiling joist in accordance with this schedule and the <br />ceiling joist is fastened to the top plate in accordance with this schedule, the number of toe nails in the <br />rafter shall be permitted to be reduced by one nail. <br />2. Refer to the Design Criteria section on this page for roof and floor sheathing nailing schedule <br />3. Refer to the Shear Wall Schedule on this page for nailing requirements at wood structural panels <br />DESIGN WIND SPEED, V 95 mph EXPOSURE B RISK CATEGORY II <br />SN1 <br />N/A <br />10/15/24 <br />GE <br />N <br />E <br />R <br />A <br />L <br /> <br />N <br />O <br />T <br />E <br />S <br /> <br />Cl <br />i <br />e <br />n <br />t <br />: <br />Ar <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />: <br />RESTRICTIVE NOTICE <br />THESE DRAWINGS ARE THE SOLE PROPERTY <br />OF JJS STRUCTURAL, INC. AND MAY NOT BE <br />REPRODUCED WITHOUT THE WRITTEN <br />CONSENT OF AN OFFICER OF OUR FIRM. THE <br />PLANS ARE ONLY TO BE USED FOR THIS <br />SPECIFIC PROJECT AND ARE NOT APPLICABLE <br />TO ANY OTHER STRUCTURE. <br />9 7 5 1 O l y m p i c D r i v e <br />H u n t i n g t o n B e a c h , C A 9 2 6 4 6 <br />7 1 4 -4 9 6 -6 7 7 2 <br />JOB NO.: <br />ISSUE DATE: <br />SCALE: <br />SHEET NO. <br />24051 <br />RA <br />I <br />L <br />I <br />N <br />G <br /> <br />U <br />P <br />G <br />R <br />A <br />D <br />E <br />10 <br />0 <br />0 <br /> <br />W <br /> <br />M <br />a <br />c <br />A <br />r <br />t <br />h <br />u <br />r <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />Fo <br />w <br />e <br />r <br />s <br /> <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br />, <br /> <br />I <br />n <br />c <br />. <br />Fo <br />w <br />e <br />r <br />s <br /> <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br />, <br /> <br />I <br />n <br />c <br />. <br /> <br />STATE OF CALIFORNIA <br />JASON SK UDLARSKINo. C67712 <br />Exp. 06/30/25 <br />CIV IL <br />REGISTERED PROFESSIONAL ENGINEER <br />REVISIONS DATE <br />1 PLAN CHECK 01/13/25 <br />1000 W MacArthur Blvd <br />Unit# 721/23/2025