Laserfiche WebLink
Project : <br />Project Number: <br />By : <br />Date : <br />Castrejon, Jonathan <br />PE <br />07-10-2022 <br />Check for Increase in overall seismic loads <br />Array Area = ft2 <br />Number of Arrays = <br />Total Array Area = ft2 <br />Array Load = psf <br />Number of Existing Arrays = <br />Exisitng Area = ft2 <br />Total Array Wt. = lb <br />Total Roof Area = ft2 <br />DL of Roof = psf <br />Total Wt of Roof = lb <br />Increase in Seismic Wt = < <br />20.0 <br />10% <br />Conservativelsy the Wt. of the Walls tributary to the roof is not included. Seismic weight increase is less thaan <br />10% and no seismic retrofit or evaluation of existing lateral system is required per Section 503.4 of 2019 <br />CEBC. <br />15 <br />300.16 <br />3.00 <br />0 <br />0.00 <br />900.48 <br />1903.6 <br />13.20 <br />25127 <br />3.6% <br />1334 S Olive St <br />12/05/22