TITLE 24 ENERGY
<br />COMPLIANCE
<br />NEW DETACHED ADU
<br />2039 N VICTORIA DR UNIT #2
<br />SANTA ANA, CA, 92706
<br />24-1055
<br />9/13/2024
<br />NTS
<br />T101
<br />Jeffrey Schaefer, P.E.
<br />(562) 850-1223
<br />License Number - C91734
<br />Expiration Date - Dec 31, 2026
<br />3325 E 4th St.
<br />Long Beach, CA 90814
<br />CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E
<br />ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page1of12)
<br />CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22
<br />RegistrationNumber:RegistrationDate/Time: HERSProvider:
<br />CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000
<br />SchemaVersion:rev20220901
<br />ReportGenerated:2025-03-07 13:54:06
<br />GENERAL INFORMATION
<br />01 Project Name New Unit Construction
<br />02 Run Title New Construction
<br />03 Project Location 2039 N Victoria Dr
<br />04 City Santa Ana, CA 05 Standards Version 2022
<br />06 Zip code 92706 07 Software Version CBECC-Res2022.3.1
<br />08 Climate Zone 8 09 Front Orientation (deg/Cardinal) 270
<br />10 Building Type Single family 11 Number of Dwelling Units 1
<br />12 Project Scope Newly Constructed 13 Number of Bedrooms 1
<br />14 Addition Cond. Floor Area (ft2) 0 15 Number of Stories 1
<br />16 Existing Cond. Floor Area (ft2) n/a 17 Fenestration Average U-factor 0.31
<br />18 Total Cond. Floor Area (ft2) 998 19 Glazing Percentage (%) 25.15%
<br />20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a
<br />22 Fuel Type All electric 23 No Dwelling Unit: No
<br />01
<br />02
<br />03
<br />425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS
<br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
<br />and cannot guarantee, the accuracy or completeness of the information contained in this document.
<br />COMPLIANCE RESULTS
<br />Building Complies with Computer Performance
<br />This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
<br />This building incorporates one or more Special Features shown below
<br />CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E
<br />ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page2of12)
<br />CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22
<br />RegistrationNumber:RegistrationDate/Time: HERSProvider:
<br />CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000
<br />SchemaVersion:rev20220901
<br />ReportGenerated:2025-03-07 13:54:06
<br />ENERGY DESIGN RATINGS
<br />EnergyDesignRatings ComplianceMargins
<br />SourceEnergy
<br />(EDR1)
<br />Efficiency1EDR
<br />(EDR2efficiency)
<br />Total2EDR
<br />(EDR2total)
<br />SourceEnergy
<br />(EDR1)
<br />Efficiency1EDR
<br />(EDR2efficiency)
<br />Total2EDR
<br />(EDR2total)
<br />StandardDesign 36.3 36.7 53.7
<br />ProposedDesign 34.4 36.6 53.7 1.9 0.1 0
<br />RESULT3:PASS
<br />1Efficiency EDRincludesimprovementslikeabetterbuildingenvelopeandmoreefficientequipment
<br />2Total EDRincludesefficiencyanddemandresponsemeasuressuchasphotovoltaic(PV)systemandbatteries
<br />3Building complieswhensourceenergy,efficiencyandtotalcompliancemarginsaregreaterthanorequaltozeroandunmetloadhourlimitsarenotexceeded
<br />•Standard Design PV Capacity: 0.00 kW dc
<br />•PV System(s) removed due to Reduced PV Requirement of 0kW dc
<br />425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS
<br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
<br />and cannot guarantee, the accuracy or completeness of the information contained in this document.
<br />CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E
<br />ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page3of12)
<br />CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22
<br />RegistrationNumber:RegistrationDate/Time: HERSProvider:
<br />CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000
<br />SchemaVersion:rev20220901
<br />ReportGenerated:2025-03-07 13:54:06
<br />ENERGY USE SUMMARY
<br />EnergyUse StandardDesignSource
<br />Energy(EDR1)(kBtu/ft2-yr)
<br />StandardDesignTDVEnergy
<br />(EDR2)(kTDV/ft2-yr)
<br />ProposedDesignSource
<br />Energy(EDR1)(kBtu/ft2-yr)
<br />ProposedDesignTDVEnergy
<br />(EDR2)(kTDV/ft2-yr)Margin(EDR1) Margin(EDR2)
<br />SpaceHeating 0.6 2.74 0.82 5.82 -0.22 -3.08
<br />SpaceCooling 0.84 23.14 0.73 26.48 0.11 -3.34
<br />IAQVentilation 0.34 3.6 0.34 3.6 0 0
<br />WaterHeating 1.67 17.68 0.95 11.13 0.72 6.55
<br />Self
<br />Utilization/Flexibility
<br />Credit
<br />0 0 0 0
<br />EfficiencyCompliance
<br />Total 3.45 47.16 2.84 47.03 0.61 0.13
<br />Photovoltaics 0 0 0 0
<br />Battery 0 0
<br />Flexibility 0
<br />IndoorLighting 0.86 8.06 0.86 8.06
<br />Appl.&Cooking 3.46 41.62 3.46 41.59
<br />PlugLoads 3.62 36.84 3.62 36.84
<br />OutdoorLighting 0.2 1.75 0.2 1.75
<br />TOTALCOMPLIANCE 11.59 135.43 10.98 135.27
<br />425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS
<br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
<br />and cannot guarantee, the accuracy or completeness of the information contained in this document.
<br />CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E
<br />ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page4of12)
<br />CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22
<br />RegistrationNumber:RegistrationDate/Time: HERSProvider:
<br />CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000
<br />SchemaVersion:rev20220901
<br />ReportGenerated:2025-03-07 13:54:06
<br />ENERGY USE INTENSITY
<br />StandardDesign(kBtu/ft2-yr) ProposedDesign(kBtu/ft2-yr)Margin(kBtu/ft2-yr)MarginPercentage
<br />GrossEUI1 16.01 15.35 0.66 4.12
<br />NetEUI2 16.01 15.35 0.66 4.12
<br />Notes
<br />1.GrossEUIisEnergyUseTotal(notincludingPV)/TotalBuildingArea.
<br />2.NetEUIisEnergyUseTotal(includingPV)/TotalBuildingArea.
<br />REQUIRED PV SYSTEMS
<br />01 02 03 04 05 06 07 08 09 10 11 12
<br />DCSystemSize
<br />(kWdc)Exception ModuleType ArrayType PowerElectronics CFI Azimuth
<br />(deg)
<br />Tilt
<br />Input
<br />ArrayAngle
<br />(deg)
<br />Tilt:(xin
<br />12)
<br />InverterEff.
<br />(%)
<br />Annual
<br />SolarAccess
<br />(%)
<br />0 NoPV-requiredPV
<br />lessthan1.8kWdc Standard(14-17%)Fixed none true n/a n/a n/a n/a n/a
<br />REQUIRED SPECIAL FEATURES
<br />•PV exception 2: No PV required when minimum PV size (Section150.1(c)14)<1.8kWdc(0kW)
<br />•Cool roof
<br />•Insulation below roof deck
<br />•Compact distribution system basic credit
<br />•Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed
<br />425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS
<br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
<br />and cannot guarantee, the accuracy or completeness of the information contained in this document.
<br />The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
<br />CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E
<br />ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page5of12)
<br />CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22
<br />RegistrationNumber:RegistrationDate/Time: HERSProvider:
<br />CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000
<br />SchemaVersion:rev20220901
<br />ReportGenerated:2025-03-07 13:54:06
<br />HERS FEATURE SUMMARY
<br />•Quality insulation installation (QII)
<br />•Indoor air quality ventilation
<br />•Kitchen range hood
<br />•Minimum Airflow
<br />•Verified SEER/SEER2
<br />•Verified Refrigerant Charge
<br />•Fan Efficacy Watts/CFM
<br />•Verified heat pump rated heating capacity
<br />BUILDING-FEATURESINFORMATION
<br />01 02 03 04 05 06 07
<br />ProjectName ConditionedFloorArea(ft2)NumberofDwelling
<br />Units NumberofBedrooms NumberofZones NumberofVentilation
<br />CoolingSystems
<br />NumberofWater
<br />HeatingSystems
<br />NewUnitConstruction 998 1 1 1 0 1
<br />ZONEINFORMATION
<br />01 02 03 04 05 06 07
<br />ZoneName ZoneType HVACSystemName ZoneFloorArea(ft2)Avg.CeilingHeight WaterHeatingSystem1 Status
<br />ADU Conditioned NewADUHVAC 998 9 HeatPumpWH New
<br />OPAQUESURFACES
<br />01 02 03 04 05 06 07 08
<br />Name Zone Construction Azimuth Orientation GrossArea(ft2)WindowandDoor
<br />Area(ft2)Tilt(deg)
<br />WallFront ADU R-21WallStucco 270 Front 351 89.02 90
<br />WallLeft ADU R-21WallStucco 0 Left 348 116.02 90
<br />WallBack ADU R-21WallStucco 90 Back 351 0 90
<br />WallRight ADU R-21WallStucco 180 Right 348 4 90
<br />Ceiling(belowattic)ADU R-30Ceiling n/a n/a 378 n/a n/a
<br />425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS
<br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
<br />and cannot guarantee, the accuracy or completeness of the information contained in this document.
<br />The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
<br />detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
<br />CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E
<br />ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page6of12)
<br />CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22
<br />RegistrationNumber:RegistrationDate/Time: HERSProvider:
<br />CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000
<br />SchemaVersion:rev20220901
<br />ReportGenerated:2025-03-07 13:54:06
<br />OPAQUE SURFACES-CATHEDRAL CEILINGS
<br />01 02 03 04 05 06 07 08 09 10 11
<br />Name Zone Construction Azimuth Orientation Area(ft2)
<br />SkylightArea
<br />(ft2)
<br />RoofRise(xin
<br />12)
<br />Roof
<br />Reflectance RoofEmittance CoolRoof
<br />Cathedral
<br />CeilingFront ADU RoofCeiling 270 Front 310 21 5 0.2 0.85 Yes
<br />Cathedral
<br />CeilingBack ADU RoofCeiling 90 Back 310 21 5 0.2 0.85 Yes
<br />ATTIC
<br />01 02 03 04 05 06 07 08
<br />Name Construction Type RoofRise(xin12)RoofReflectance RoofEmittance RadiantBarrier CoolRoof
<br />Attic AsphaltShingleRoof Ventilated 5 0.2 0.85 No Yes
<br />FENESTRATION/GLAZING
<br />01 02 03 04 05 06 07 08 09 10 11 12 13 14
<br />Name Type Surface Orientation Azimuth Width
<br />(ft)
<br />Height
<br />(ft)Mult.Area
<br />(ft2)U-factor U-factor
<br />Source SHGC SHGCSource ExteriorShading
<br />F1 Window WallFront Front 270 6 6.67 1 40.02 0.3 NFRC 0.23 NFRC BugScreen
<br />F2 Window WallFront Front 270 2 6 2 24 0.3 NFRC 0.23 NFRC BugScreen
<br />F3 Window WallFront Front 270 2.5 2 5 25 0.3 NFRC 0.23 NFRC BugScreen
<br />L1 Window WallLeft Left 0 6 6.67 1 40.02 0.3 NFRC 0.23 NFRC BugScreen
<br />L2 Window WallLeft Left 0 2 6 4 48 0.3 NFRC 0.23 NFRC BugScreen
<br />L3 Window WallLeft Left 0 2 3.5 4 28 0.3 NFRC 0.23 NFRC BugScreen
<br />R1 Window WallRight Right 180 2 2 1 4 0.3 NFRC 0.23 NFRC BugScreen
<br />Skylight1 Skylight Cathedral
<br />CeilingFront Front 270 3 21 0.38 NFRC 0.25 NFRC
<br />425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS
<br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
<br />and cannot guarantee, the accuracy or completeness of the information contained in this document.
<br />CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E
<br />ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page7of12)
<br />CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22
<br />RegistrationNumber:RegistrationDate/Time: HERSProvider:
<br />CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000
<br />SchemaVersion:rev20220901
<br />ReportGenerated:2025-03-07 13:54:06
<br />FENESTRATION/GLAZING
<br />01 02 03 04 05 06 07 08 09 10 11 12 13 14
<br />Name Type Surface Orientation Azimuth Width
<br />(ft)
<br />Height
<br />(ft)Mult.Area
<br />(ft2)U-factor U-factor
<br />Source SHGC SHGCSource ExteriorShading
<br />Skylight2 Skylight Cathedral
<br />CeilingBack Back 90 3 21 0.38 NFRC 0.25 NFRC
<br />SLABFLOORS
<br />01 02 03 04 05 06 07 08
<br />Name Zone Area(ft2)Perimeter(ft)EdgeInsul.R-value
<br />andDepth
<br />EdgeInsul.R-value
<br />andDepth CarpetedFraction Heated
<br />SlabOnGrade ADU 998 146 none 0 80%No
<br />OPAQUESURFACECONSTRUCTIONS
<br />01 02 03 04 05 06 07 08
<br />ConstructionName SurfaceType ConstructionType Framing TotalCavity
<br />R-value
<br />Interior/Exterior
<br />Continuous
<br />R-value
<br />U-factor AssemblyLayers
<br />R-21WallStucco ExteriorWalls WoodFramedWall 2x6@16in.O.C.R-21 None/5 0.048
<br />InsideFinish:GypsumBoard
<br />Cavity/Frame:R-21/2x6
<br />Sheathing/Insulation:R-5Sheathing
<br />ExteriorFinish:3CoatStucco
<br />RoofCeiling CathedralCeilings WoodFramed
<br />Ceiling 2x10@24in.O.C.R-30 None/None 0.035
<br />Roofing:LightRoof(AsphaltShingle)
<br />RoofDeck:Wood
<br />Siding/sheathing/decking
<br />Cavity/Frame:R-30/2x10
<br />InsideFinish:GypsumBoard
<br />AsphaltShingleRoof AtticRoofs WoodFramed
<br />Ceiling 2x6@16in.O.C.R-19 None/None 0.058
<br />Roofing:LightRoof(AsphaltShingle)
<br />RoofDeck:Wood
<br />Siding/sheathing/decking
<br />Cavity/Frame:R-19/2x6
<br />425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS
<br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
<br />and cannot guarantee, the accuracy or completeness of the information contained in this document.
<br />CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E
<br />ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page8of12)
<br />CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22
<br />RegistrationNumber:RegistrationDate/Time: HERSProvider:
<br />CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000
<br />SchemaVersion:rev20220901
<br />ReportGenerated:2025-03-07 13:54:06
<br />OPAQUESURFACECONSTRUCTIONS
<br />01 02 03 04 05 06 07 08
<br />ConstructionName SurfaceType ConstructionType Framing TotalCavity
<br />R-value
<br />Interior/Exterior
<br />Continuous
<br />R-value
<br />U-factor AssemblyLayers
<br />R-30Ceiling Ceilings(below
<br />attic)
<br />WoodFramed
<br />Ceiling 2x6@16in.O.C.R-30 None/None 0.032
<br />OverCeilingJoists:R-15.7insul.
<br />Cavity/Frame:R-14.3/2x6
<br />InsideFinish:GypsumBoard
<br />BUILDINGENVELOPE-HERSVERIFICATION
<br />01 02 03 04 05
<br />QualityInsulationInstallation(QII)HighR-valueSprayFoamInsulation BuildingEnvelopeAirLeakage CFM50 CFM50
<br />Required NotRequired N/A n/a n/a
<br />WATERHEATINGSYSTEMS
<br />01 02 03 04 05 06 07 08 09
<br />Name SystemType DistributionType WaterHeaterName NumberofUnits SolarHeating
<br />System
<br />Compact
<br />Distribution HERSVerification WaterHeater
<br />Name(#)
<br />HeatPumpWH DomesticHot
<br />Water(DHW)Standard HeatPumpWater
<br />Heater 1 n/a Basic n/a HeatPumpWater
<br />Heater(1)
<br />WATERHEATERS-NEEAHEATPUMP
<br />01 02 03 04 05 06 07 08
<br />Name #ofUnits TankVol.(gal)NEEAHeatPump
<br />Brand
<br />NEEAHeatPump
<br />Model TankLocation DuctInletAirSource DuctOutletAirSource
<br />HeatPumpWater
<br />Heater 1 50 A.O.Smith HPTS-502**(50gal,
<br />JA13)Outside Outside Outside
<br />425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS
<br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
<br />and cannot guarantee, the accuracy or completeness of the information contained in this document.
<br />CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E
<br />ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page9of12)
<br />CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22
<br />RegistrationNumber:RegistrationDate/Time: HERSProvider:
<br />CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000
<br />SchemaVersion:rev20220901
<br />ReportGenerated:2025-03-07 13:54:06
<br />WATERHEATING-COMPACTDISTRIBUTION
<br />01 02 03 04 05 06 07
<br />DwellingUnittype WaterHeatingSystem
<br />Name
<br />MasterBathdistanceof
<br />furthestfixturetoWater
<br />Heater(ft)
<br />Kitchendistanceof
<br />furthestfixturetoWater
<br />Heater(ft)
<br />FurthestThirdfurthest
<br />fixturetoWaterHeater
<br />(ft)
<br />CompactnessFactor HERSVerification
<br />Dwelling HeatPumpWH n/a n/a n/a 0.7 n/a
<br />WATERHEATING-HERSVERIFICATION
<br />01 02 03 04 05 06 07
<br />Name PipeInsulation ParallelPiping CompactDistribution CompactDistribution
<br />Type RecirculationControl ShowerDrainWaterHeat
<br />Recovery
<br />HeatPumpWH-1/1 NotRequired NotRequired NotRequired Basic NotRequired NotRequired
<br />SPACECONDITIONINGSYSTEMS
<br />01 02 03 04 05 06 07 08 09
<br />Name SystemType HeatingUnitName HeatingEquipment
<br />Count CoolingUnitName CoolingEquipment
<br />Count FanName DistributionName Required
<br />ThermostatType
<br />NewADUHVAC Heatpump
<br />heatingcooling HVACHeatPump 1 HVACHeatPump 1 HVACFan Ducts Setback
<br />HVAC-HEATPUMPS
<br />01 02 03 04 05 06 07 08 09 10 11 12 13
<br />Name SystemType Numberof
<br />Units
<br />Heating Cooling
<br />Zonally
<br />Controlled
<br />Compressor
<br />Type
<br />Heating HERSVerificationEfficiency
<br />Type
<br />HSPF/HS
<br />PF2/COP Cap47 Cap17
<br />Cooling
<br />Efficiency
<br />Type
<br />SEER/SE
<br />ER2
<br />EER/EER
<br />2/CEER
<br />HVACHeatPump CentralsplitHP 1 HSPF2 7.5 30000 30000 EER2SEER2 18 12.48 NotZonal Single
<br />Speed
<br />HVACHeat
<br />Pump-hers-htpump
<br />425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS
<br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
<br />and cannot guarantee, the accuracy or completeness of the information contained in this document.
<br />CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E
<br />ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page10of12)
<br />CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22
<br />RegistrationNumber:RegistrationDate/Time: HERSProvider:
<br />CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000
<br />SchemaVersion:rev20220901
<br />ReportGenerated:2025-03-07 13:54:06
<br />HVACHEATPUMPS-HERSVERIFICATION
<br />01 02 03 04 05 06 07 08 09
<br />Name VerifiedAirflow AirflowTarget VerifiedEER/EER2 Verified
<br />SEER/SEER2
<br />VerifiedRefrigerant
<br />Charge
<br />Verified
<br />HSPF/HSPF2
<br />VerifiedHeating
<br />Cap47
<br />VerifiedHeating
<br />Cap17
<br />HVACHeat
<br />Pump-hers-htpump Required 350 NotRequired Required Yes No Yes Yes
<br />HVAC-DISTRIBUTIONSYSTEMS
<br />01 02 03 04 05 06 07 08 09 10 11 12
<br />Name Type DesignType DuctIns.R-value DuctLocation SurfaceArea BypassDuct DuctLeakage HERSVerificationSupplyReturnSupplyReturnSupplyReturn
<br />Ducts Unconditioned
<br />attic Non-Verified R-6 R-6 Attic Attic n/a n/a NoBypassDuct Existing(not
<br />specified)Ducts-hers-dist
<br />HVAC-FANSYSTEMS
<br />01 02 03 04
<br />Name Type FanPower(Watts/CFM)Name
<br />HVACFan HVACFan 0.45 HVACFan-hers-fan
<br />HVACFANSYSTEMS-HERSVERIFICATION
<br />01 02 03
<br />Name VerifiedFanWattDraw RequiredFanEfficacy(Watts/CFM)
<br />HVACFan-hers-fan Required 0.45
<br />425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS
<br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
<br />and cannot guarantee, the accuracy or completeness of the information contained in this document.
<br />CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E
<br />ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page11of12)
<br />CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22
<br />RegistrationNumber:RegistrationDate/Time: HERSProvider:
<br />CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000
<br />SchemaVersion:rev20220901
<br />ReportGenerated:2025-03-07 13:54:06
<br />INDOOR AIR QUALITY (IAQ) FANS
<br />01 02 03 04 05 06 07 08 09
<br />DwellingUnit Airflow(CFM)FanEfficacy
<br />(W/CFM)IAQFanType
<br />Includes
<br />Heat/Energy
<br />Recovery?
<br />IAQRecovery
<br />Effectiveness-
<br />SRE/ASRE
<br />IncludesFault
<br />IndicatorDisplay?HERSVerification Status
<br />SFamIAQVentRpt 44 0.35 Exhaust No n/a/n/a No Yes
<br />425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS
<br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
<br />and cannot guarantee, the accuracy or completeness of the information contained in this document.
<br />CERTIFICATEOFCOMPLIANCE-RESIDENTIALPERFORMANCECOMPLIANCEMETHOD CF1R-PRF-01-E
<br />ProjectName:NewUnitConstruction CalculationDate/Time:2025-03-07T13:53:27-08:00 (Page12of12)
<br />CalculationDescription:NewConstruction InputFileName:2039NVictoriaDr.ribd22
<br />RegistrationNumber:RegistrationDate/Time: HERSProvider:
<br />CABuildingEnergyEfficiencyStandards-2022ResidentialCompliance ReportVersion:2022.0.000
<br />SchemaVersion:rev20220901
<br />ReportGenerated:2025-03-07 13:54:06
<br />DocumentationAuthorName:DocumentationAuthorSignature:
<br />Company:SignatureDate:
<br />Address:CEA/HERSCertificationIdentification(Ifapplicable):
<br />City/State/Zip:Phone:
<br />1.
<br />2.
<br />3.
<br />ResponsibleDesignerName:ResponsibleDesignerSignature:
<br />Company:DateSigned:
<br />Address:License:
<br />City/State/Zip:Phone:
<br />Jeffrey Schaefer
<br />JRS Engineering & Design 03/07/2025
<br />3325 E 4th
<br />Long Beach, CA 80914 5628501223
<br />Jeffrey Schaefer
<br />JRS Engineering & Design 03/07/2025
<br />3325 E 4th C91734
<br />Long Beach, CA 80914 5628501223
<br />425-P010072410A-000-000-0000000-0000 03/07/2025 17:11 CHEERS
<br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
<br />and cannot guarantee, the accuracy or completeness of the information contained in this document.
<br />Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of
<br />this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.
<br />DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
<br />1. I certify that this Certificate of Compliance documentation is accurate and complete.
<br />RESPONSIBLE PERSON'S DECLARATION STATEMENT
<br />I certify the following under penalty of perjury, under the laws of the State of California:
<br />I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
<br />I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title24, Part1 and Part 6 of the California Code of Regulations.
<br />The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
<br />calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
<br />2039 N Victoria Drive
<br />#24/28/2025
|