My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2039 N Victoria Drive #2 - Plan
PBA
>
Building
>
ProjectDox
>
V
>
Victoria Dr
>
2039 N Victoria Dr Unit# 2
>
2039 N Victoria Drive #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2025 12:29:09 PM
Creation date
6/15/2025 12:29:02 PM
Metadata
Fields
Template:
Plan
Permit Number
101122463
Full Address
2039 N Victoria Dr Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 2 <br />2022 California Building Code ASDPROJECT: 2039 N Victoria Dr <br />Module Level: Roof <br />Module Type: Roof Beam <br />Material Type: Solid Sawn Douglas Fir-Larch No. 2 <br />Member Dimensions: (1) 3.5 in. X 5.5 in. X 5 ft <br />Section Adequacy:67.12% <br />Controlling Factor: Bending Stress Y <br />Module Location: Ceiling Flush Beam - Kitchen Soffit <br />Module Level: Roof <br />Module Type: Roof Beam <br />Material Type: Solid Sawn Douglas Fir-Larch No. 2 <br />Member Dimensions: (1) 3.5 in. X 5.5 in. X 12.33 ft <br />Section Adequacy:51.76% <br />Controlling Factor: Bending Stress Y <br />Module Location: Ridge Beam Post <br />Module Level: Main Floor <br />Module Type: Column <br />Material Type: Solid Sawn Douglas Fir-Larch No. 2 <br />Member Dimensions: (1) 3.5 in. X 5.5 in. X 12.5 ft <br />Section Adequacy:58.02% <br />Controlling Factor: Compressive Stress <br />Module Location: Ridge Beam Footing <br />Module Level: Basement <br />Module Type: Isolated Footing <br />Material Type: Concrete <br />Member Dimensions: 2.5 ft. wide X 24 in. tall X 2.5 ft long <br />Section Adequacy:26.64% <br />Controlling Factor: Soil Bearing Pressure <br />Reinforcement: #4 - Longitudinal: 7 Bars. Transversal: 7 Bars <br />Module Location: Door Header Footing <br />Module Level: Basement <br />Module Type: Isolated Footing <br />Material Type: Concrete <br />Member Dimensions: 2 ft. wide X 24 in. tall X 2 ft long <br />Section Adequacy:27.99% <br />Controlling Factor: Soil Bearing Pressure <br />Reinforcement: #4 - Longitudinal: 6 Bars. Transversal: 6 Bars <br />Module Location: New Continuous Footing <br />Module Level: Basement <br />Module Type: Continuous Footing <br />Material Type: Concrete <br />Member Dimensions: 1.5 ft. wide X 24 in. tall <br />Section Adequacy:66.9% <br />Controlling Factor: Soil Bearing Pressure <br />Reinforcement: Unreinforced (Plain) <br />2039 N Victoria Drive <br />#24/28/2025
The URL can be used to link to this page
Your browser does not support the video tag.