Laserfiche WebLink
JRS ENGINEERING & DESIGN LLCJEFFREY SCHAEFEC:\Users\rache\OneDrive\Documents\JRS Engineering\...\Roof Structure - Simple Gable with CJ.vapWednesday, November 27, 2024 2:45 PM <br />VisualAnalysis 21.00.0003, Full Desi <br />www.iesweb.com Page 5 of 6 <br />Roof Rafters: Axial Check (extreme rows: max <br />Member Section Offset <br />ft <br />Result Case Demand fa <br />Ksi <br />Capacity Fa <br />Ksi <br />Code <br />Reference <br />Unity Check Details <br />RR-Left SS 2x6 0.0000 3. 1.2D+1.6Lr+L -0.1266 1.1154 3.6.3 0.1135 <br />Fx = -1.0442 K, KLz = 10.835 ft, <br />KLy = 0 ft, Fc* = 2.6611 Ksi, <br />FcE = 1.2763 Ksi, CM(Fc) = 1, <br />Ct = 1, CF(Fc) = 1.1, <br />Ci = 1, Kf(Compression) = 2.4, <br />ϕ = 0.85, CP = 0.41914, <br />CM(E) = 1, CT = 1, <br />Cfu = 1, Kf(Emin) = 1.76, <br />Lambda = 0.8, Kz = 1, <br />Ky = 1 <br />RR-Right SS 2x6 10.8346 3. 1.2D+1.6Lr+L -0.1266 1.1154 3.6.3 0.1135 <br />Fx = -1.0442 K, KLz = 10.835 ft, <br />KLy = 0 ft, Fc* = 2.6611 Ksi, <br />FcE = 1.2763 Ksi, CM(Fc) = 1, <br />Ct = 1, CF(Fc) = 1.1, <br />Ci = 1, Kf(Compression) = 2.4, <br />ϕ = 0.85, CP = 0.41914, <br />CM(E) = 1, CT = 1, <br />Cfu = 1, Kf(Emin) = 1.76, <br />Lambda = 0.8, Kz = 1, <br />Ky = 1 <br />Roof Rafters: Strong Flexure Check (extreme rows: max) <br />Member Section Offset <br />ft <br />Result Case Demand fbz <br />Ksi <br />Capacity Fbz <br />Ksi <br />Code <br />Reference <br />Unity Check Details <br />RR-Left SS 2x6 5.4173 3. 1.2D+1.6Lr+L 1.3886 2.1946 3.3-1 0.6327 <br />Lb = 0 ft, Mz = 0.87509 K-ft, <br />E'min = 867.68 Ksi, CM(E) = 1, <br />Ct = 1, Ci = 1, <br />CT = 1, Cfu = 1, <br />Kf(Emin) = 1.76, ϕ = 0.85, <br />CM(Fb) = 1, CL = 0.99989, <br />CF(Fb) = 1.3, Cr = 1.15, <br />Kf(Bending) = 2.54, Lambda = 0.8 <br />RR-Right SS 2x6 5.4173 3. 1.2D+1.6Lr+L 1.3886 2.1946 3.3-1 0.6327 <br />Lb = 0 ft, Mz = 0.87509 K-ft, <br />E'min = 867.68 Ksi, CM(E) = 1, <br />Ct = 1, Ci = 1, <br />CT = 1, Cfu = 1, <br />Kf(Emin) = 1.76, ϕ = 0.85, <br />CM(Fb) = 1, CL = 0.99989, <br />CF(Fb) = 1.3, Cr = 1.15, <br />Kf(Bending) = 2.54, Lambda = 0.8 <br />Roof Rafters: Strong Shear Check (extreme rows: max) <br />Member Section Offset <br />ft <br />Result Case Demand fvy <br />Ksi <br />Capacity Fvy <br />Ksi <br />Code <br />Reference <br />Unity Check Details <br />RR-Left SS 2x6 10.8346 3. 1.2D+1.6Lr+L -0.0587 0.3110 3.4-1 0.1889 <br />V = -0.32307 K, CM = 1, <br />Ct = 1, Ci = 1, <br />Kf(Shear) = 2.88, ϕ = 0.75, <br />Lambda = 0.8 <br />RR-Right SS 2x6 10.8346 3. 1.2D+1.6Lr+L -0.0587 0.3110 3.4-1 0.1889 <br />V = -0.32307 K, CM = 1, <br />Ct = 1, Ci = 1, <br />Kf(Shear) = 2.88, ϕ = 0.75, <br />Lambda = 0.8 <br />2039 N Victoria Drive <br />#24/28/2025