Laserfiche WebLink
G E N E R A L N O T E S <br />A. PURPOSE <br />The intent of this standard plan is to promote public safety and <br />welfare by reducing the risk of earthquake Induced damage In <br />existing wood frame residential buDdlngs. The requirements <br />represented here ore minimum prescriptive standards which do not <br />meet the requirements for new buildings. These standards ore <br />intended to improve the seismic performance of these existing <br />buildings but will no t necessarlly prevent their damage In cm <br />earthquake. Their primary purpose is to reduce the likelihood that <br />these bulldlngs wlll fall off their foundations. (per Oiopter 92 of <br />the Los Angeles BuHdlng Code) <br />8. SCOPE <br />These standards apply to one, two and three story resldentlol <br />buildings with raised wood floors If they meet the following criteria: <br />1) cripple wall heights do not exceed 48 Inches In one or two <br />story buildings and do not exceed 14 inch stud height in three <br />story buildings <br />2) the building ls supported at Its perimeter by a continuous <br />concrete footing and stem well <br />3 ) all o f the floors in each story ore at the same elevation. <br />4) the ma,clmum number of dwelling units and/or guest rooms Is <br />four. <br />5) the cripple walls ore sheathed with materials other than wood <br />structural panels or diagonal sheathing. <br />6) no portion of the building is constructed over o elope steeper <br />than 3 horizontal to 1 vertical. <br />C. GENERAL REQUIREMENTS <br />PERMIT REQUIREMENTS: All work shown on these plans requires a <br />building permit. <br />PRE-INSPECTION REQUIREMENTS: None <br />INSPECTION REQUIREMENlS: All footing excavations and placement <br />of reinforcing steel and anchor bolts In formwork shall be <br />Inspected prior to pouring of concrete for replacement footings <br />and stem walls. <br />All cripple wall bracing, blocking, connectors and anchors In existing <br />concrete shall be inspected after the work ls completed but before <br />the screens for the ventllotlon holes at the sill plate anchors are <br />completely fastened. <br />DEPUTY INSPECTION: None <br />STRUCTURAL OBSERVATION: None <br />D. DEFINITIONS <br />ADHESIVE ANCHOR is a fastener placed in hardened concrete that <br />derives Its holding strength from a chemical 0dhesive compound <br />placed between the wall o f the hole and the embedded portion of <br />the anchor. Chemlcal adhesive compounds are organic compounds. <br />comprised of resin and hardener, that form adhesives when <br />blended together. Examples of chemical adhesive compounds can <br />Include epoxies, pol)Urethcmes. polyesters, meth)'t methoa-)'tates <br />and vinylesters. <br />ANCHOR SIPE PLAT£ Is a metal plate or plates used to connect the <br />sill plate or floor framing to the side of a concrete stem wall when <br />conditions prevent anchor or bait installation vertically through <br />the am plate. <br />APPROVAL Is current product acceptance under a City of Los <br />Angeles Research Report for all of the conditions of the <br />Intended use except continuous inspection of anchors. <br />BOLT RING i s a metal or plastic piece of pipe placed around a <br />bolt In a wood sll plate to fill In the annular space created <br />by on oversized drilled hole. <br />EMBEDMENT DEPTH Is the depth of the anchor Into the concrete <br />prior to setting of the anchor <br />EXPANSION ANCHOR Is a mechanical fastener placed ln hardened <br />cona-ete designed to expcind In a self-drilled or pre-drilled <br />hole of a specified size and engage the sides of the hole in one <br />or more locations to develop shear cind/or tension resistance to <br />applied loads without grout. cidheslve o r dr~ack. <br />INSTAI I ATION IDROUE Is the minimum moment applied to a <br />torque-set anchor that creates the degree of anchorage required <br />for full load values. <br />M INIMUM CONCRElE EDGE DISTANCE Is the measure between the free <br />edge of the concrete and the centerline of the bolt at which the <br />concrete will no t break away when th e anchor is set or loaded in <br />service. Minimum edge distances for anchors are given In th e <br />product approval. <br />SNUG TIGHT Is the condition when the full surface of the plate <br />washer Is in contact with the wood member and begins to slightly <br />Indent the wood surface. <br />TORQUE-SET ANCHOR Is an expansion anchor whose wedge or sleeve <br />engages the concrete base material In the drilled hole by the <br />oppllcotlon of torque and where the amount of torque applied <br />controls the degree of anchorage. <br />E. MATERIALS <br />ADHESIVE ANCHOR ROD M ATERIALS: All adhesive anchors shall use <br />all-thread rod mcr,ufacfured from ASTM A193, grade B7, ASTM A36, <br />or as specified In approved research report. <br />All thread rods shall be free of oil, scale and rust. The use of <br />smooth or partially threaded rods or bolts is prohibited. <br />ADHESIVE PACKAGING: The packaging for each adhesive shall be <br />marked with the manufacturer's name and address, lot number or <br />date of packaging, shelf life or expiration date, name of the quality <br />control agency, and instructions for installation. No adhesive shall be <br />used ofter lta expiration dote. <br />ANCHORS; All adhesive or expansion anchors shall hove a minimum <br />normal lood capacity of 635 lbs for 1 /2 Inch bolts and 980 lbs. for <br />5 /8 inch bolts In 2000 psi concrete at the Installed edge distance <br />and depth of embedment. All proprietary 0nchors shall hove current <br />City of Los Angeles Research Report approval. Comply with all <br />conditions of LARR for approval. <br />ANCHOR SIDE PLATE: All anchor side plates shall be of minimum 7 <br />gauge steel (3/16 inch) unless otherwise approved (i.e. 12 gouge in <br />a Research Report) and galvanized when exposed to weather. The <br />minimum seismic adj.Jsted load capacity for shear in the direction of <br />the slll plate must meet or exceed a capacity of 1275 lbs. when <br />substituted for 5 /8 Inch bolts and 840 lbs when substituted for 1 /2 <br />Inch bolts. other products with lower approved capacities may be <br />used If their required spacing ls reduced proportionately by the ratio <br />of their strength to the strength requirement above. (I.e. [ 400 lbs <br />/840 lbs] x 72 In. o.c. = use 34 In o.c. Instead of 72 In o.c. for <br />one story on anchor side plate with allowable value of 400 lbs <br />Instead of 840 lbs or greater). Anchor side plates shall be attached <br />to the concrete stem wall with a minimum of 2 - 1 /2 Inch <br />approved anchors. The number of expansion or adhesive anchors <br />used must hove a total shear capacity in concrete aqua or greater <br />to the value for the foundation anchor requirement above.I <br />BOLT RINGS: B olt rings shall be of schedule 40 galVC1nlzed Iron <br />or PVC pipe <br />CONCRE'IE: All new cona-ete for replacement footings shall be of <br />2500 psi minimum compressive strength. No epeclol inspection is <br />required. <br />FASTENERS IN PRESERVAllVE TREATED WOOD: Fasteners In <br />preservative-treated wood shall be of hot dipped zinc-c0C1ted <br />galvanized steel, stainless steel.silicone bronze, or copper. The <br />zinc coating weights shall be In accordance with ASlM A 153 <br />FRAMING ANCHORS: All framin.s, anchors shall be of minimum 18 <br />gouge galVC1nized steal, of 4 - ~ Inch length and approved under a <br />City of Los Angeles Research Report for wood frame construction. <br />The seismic load capacity in the long direction must meet or <br />exceed 450 lbs in dry lumber. The fasteners must be 1 2- 8d <br />common x t i inch nails unless otherwise approved. f/6 x 1.5 inch <br />flat head wood screws may be used at existing rlm joist, <br />blocking or top plate connections. <br />WM BER: All new lumber installed for blocking shall be o minimum <br />of nominal two Inch Douglas Fir-Larch f 2 or better as graded <br />under Western Wood Products Grading Rules. All lumber in contact <br />with concrete shall be pressure treated douglas fir-larch for <br />new stem walls and for sill plate replacements over 10X of the <br />wall length. Replacement of sill plote less than 1 0 " of the wall <br />length may use the some lumber species as the existing material. <br />All existing lumber shall be free of defects Including dryrot, <br />mildew, excessive wane, warping and insect infestation or <br />damage. Damaged lumber must be replaced and the source of water <br />or insect Intrusion removed. <br />PLATE WASHERS: Square plate washers are required. Use 3/16 x 2 <br />x 2 for 1 /2 Inch anchors and 1/4"x 2.5"x2.5"for 5 /8 Inch anchors. <br />Standard circular cut washers shall not be used to connect alll <br />plates to concrete stem walls. Washers furnished with the <br />proprietary anchors shall not be ued. Beveled washers shall be <br />used on anchors drilled at an angle exceeding 6 degrees from <br />vertical and shall be placed over the plate washers. <br />REINFORCING BAR: ASTM A615 Grade 40 or 60 <br />SHEATHING; All wood structuol panel sheathing shall be graded <br />ond conform to the requirmnerits for their t~ e in DOC PS 1 -95 <br />or DOC PS 2 -92. All wood structural panel sheathing used for <br />wall bracing shall be 15/32 inch APA roted sheathing, Exposure 1 with <br />a span rating of 32/16. Plywood shall be minimum 5 ply construction. <br />SHEATHING FASlENERS: Nalls shall be 8d common (.131 Inch x2-1/2 <br />Inch) with full heads (.281 Inch) on Interior or covered <br />sheathing. # 6 x 1-1 /2 Inch wood a crews may be substituted on <br />Interior sheathing when plaster exists on the exterior side of <br />the cripple wall. See requirements for fasteners In preservative <br />treated wood. <br />F. REPLACEMENT OF EXISTING FOOTINGS & <br />STEM WALLS <br />1. Deteriorated, cracked or unrelnforded masonry footings may be <br />replaced as shown on this pion provided proper shoring ls provided. <br />The method of shoring and sequence of Its construction <br />shall be the responslblllty of the person performing the work <br />and shall not weaken the structure so as to be a threat to the <br />safety of its occupants or passers n8Clrby. <br />2. When existing footings and stem walls are replaced in <br />sections, the pen,on performing the work shall toke care to <br />Insure that all reinforcing steel shall be lapped a minimum of 24 <br />inches and shall be dowelled into the exlsitng concrete with <br />adhesive or dr~ack a minimum of 8 Inches. <br />3. The repair of damaged footings or stem walls or the continued <br />use of archaic building materials such as unreinforced masonry, <br />requires that plans and calculations be prepared by a licensed <br />architect or engineer. <br />G. ANCHOR BOLT INSTALLATION <br />1. GENERAL REQUIREMENTS <br />A) CONDITION OF EXISTING CONCRETE: All concrete shall be fully <br />cured and hardened, uncracked and in sound condition. Concrete <br />with excessive cracking, deterioration or damage shall be <br />replaced. <br />B) DRIWNG OF THE HOLE IN CONCRETE: The drilled hole diameter <br />and minimums for spacing, depth of hole and edge distance must <br />comply with the Research Report approval and manufacturer's <br />recommendations. All holes shall be drllled with carbide-tipped <br />drlll bits conforming to ANSI Speclflcotlon B212.15-1994 <br />tole<onceo. (1/2 · 0.520-0.530. 5 /8 · 0.650-0.660 Inch) Worn <br />drill bits with reduced diameters below the ANSI tolerance <br />limits shall not be used. All holes shall be driven as <br />perpendicular as possible to the concrete surface. Right angle <br />drill motors shall be used as needed to provide the proper hole <br />orientation. <br />C) DRIWNG OE TI-IE HOLE IN WOOD; Drilled holes through existing <br />sill plates shall normally be located In the middle third of the <br />plate width. The minio,um edge distonce for the bolt from the <br />wood edge shall be 11.l b olt diameters. Anchors or bolts shall be <br />placed within 12 Inches but not less than 9 Inches from both <br />ends of all sll plate members. <br />Pl CHOICE OF USE O f ADHESIVE OR EXPANSION ANCHORS: <br />Only products approved by the Department (refer to the attachment <br />for the list of approved products and materials of construction) <br />may be used for the retrofit of crlpplewoll wortcs. <br />Both types of anchors may be used Interchangeably ln concrete <br />of average or better quality. Cona-ete of weaker quality may <br />be Indicated by spalllng during drDllng o r setting of e,cpanslon <br />anchors or failure of anchors to reach the minimum torque required. <br />Concrete of weaker quality must use adhesive anchors. <br />This requirement does not waive the need to replace existing concrete <br />foundations when damaged, deterionJted, or of unsuitable quallty. <br />2. REQUIREMENTS FOR ADHESIVE ANCHORS <br />A) CLEANING OF THE HOLE: The hole must be cleaned with a jet of <br />compressed air and a nyloo brush. Wire brushes shall not be used <br />to clean the hole. No debris or dust shall remain In the hole. <br />B~ PLACEMENT OF THE ADHESIVE: The resin, filler and hardener <br />s ail be thoroughly mixed before placement in the hole unless <br />approved to be m hced in the hole. Compounds dispensed through a <br />static mixing nozzle must be of uniform color. Ensure uniform <br />color by eKtrudlng a small amount of adhesive untn color <br />by mcinuol or pnuemotlc means from the bottom of the hole upward <br />uniformity Is achieved. Adhesive added to the hole shall be applled <br />at a slow enough rate to prevent the formation of air voids. The <br />amount of adhesive shall be sufficient to completely flll the <br />threads and annular space about the threaded rod In both the <br />concrete and any existing wood sill plate. Adhesives must be <br />installed within the manufacturer's recommended temperature <br />range for the air and concrete. <br />C) PLACEMENT OF THE THREADED ROD: The all thread rod, completely <br />free of rust, scale or oil, shall be Installed to the full depth <br />of the hole. The rod shall be turned counter-clock.wise <br />sufficiently during installation for the adhesive to engage the <br />threads. The length of the rod shall extend a minimum of one rod <br />diameter above the nut ofter tlghterilng. <br />D) ADHESIVE SETTING TIME: No torquing of the anchors shall occur <br />until the adhesive hos cured for the recommended time based on <br />the temperature as shown In the manufacturer's Instructions. <br />Care must be used to insure that the anchor bond is not <br />disturbed until the adhesive hos sufficiently cured. <br />E} TORQUE REQUIREMENTS: A m inimum torque setting of 30 ft lbs. <br />for 1 /2 Inch mchors and 40 ft lbs. for 5 /8 anchors la required for <br />all adhesive anchors for the snug tight condition unless this <br />value exceeds the maximum torque allowed by the opprovol. In those <br />cases, the torque shall be set to Its maximum allowable value. <br />3. REQUIREMENTS FOR EXPANSION ANCHORS <br />A) DRIWNG OF THE HOLE: Core must be used to insure that the <br />drilled hole carefully matches the depth and diameter <br />requirements for the expansion anchor t_)Pe. The depth of the <br />hole cannot exceed 2/3 of the concrete thickness in th e <br />direction of the drilled hole. This ls critical at the <br />appllcotlon of anchor side plates to full height concrete stem <br />walls. <br />B) CLEANING OF l HE HOLE: Unless otherwise required by the <br />manufacturer's recommendations, the drilled hale may be deepened <br />to allow the concrete debris to remain In th e hole provided the <br />hole does not exceed 2/3 of the concrete thickness In the <br />direction of the drilled hole. The depth required for embedment <br />must be free of debris. This rule does not apply to drop-In <br />anchors that rely on the bottom of a clean drilled hole to set <br />the expansion element <br />C) USE OF THE BOLT RING: B olt rings shall be required to be <br />Installed when the drDled hole ln the wood m ember exceeds the <br />bolt diameter by more thm 1 /8 inch. The length of the bolt ring <br />shall be approximately equal to the thickness of the sDI plate. <br />Chemical compounds used In adhesive anchors may be substituted <br />for bolt rings. <br />P) TORQUE REQUIREMENTS; A minimum torque setting equal to the <br />lnstollotlon torque or 30 ft lbs. for 1 /2 Inch anchors and 40 ft <br />lbs. for 5 /8 anchors, whichever Is greater, Is required for all <br />expansion anchors unless this value exceeds the maximum torque <br />allowed by the approval. In those coses, the torque shall be set <br />to Its maximum allowable value. <br />H. ANCHOR SIDE PLATE INSTALLATION <br />1. Anchor side plates may be substituted for vertlcally placed <br />anchors or bolts only when conditions prevent anchor or bolt <br />installation vertically through the am plate even with a right <br />angle drill motor.This condition commonly occurs when <br />there Is no cripple wall or one of greatly reduced height. <br />2. A minimum of two anchor side plates must be Installed on each <br />piece of sill plate 32 inches or longer. The nearest edge of the <br />plate shall be Installed a minimum of 8 inches but not more than <br />12 inches from the end of the sill plate. <br />3. Installation of the anchor bolts In the existing concrete <br />shall follow the information in Section F except as noted herein. <br />Care shall be used to Insure the drilled hole depth does not <br />exceed 2/3rds of the stem wall thickness when using expansion <br />anchors. Cleaning of the hole may be required for these <br />expansion anchors due to the limited stem wall thickness <br />ovalloble ta overdrlll the hole. <br />4. Lag screws used to attach anchor aide plates shall be <br />Installed as follows: <br />o) the lag sa-ew shall be located at the center of the plat,~ <br />thickness and shall penetrate the sill plate o minimum of 2.2 inches. <br />b) lead holes shall be pre-drilled for the threaded portion of <br />the screw. The pre-drill diameter for the lecid hole shall not <br />exceed 7 0 " of the shank diameter and shall be drilled to the <br />full depth of penetration of the lag screw. Use a 1 /4 Inch diameter <br />drlll bit for 3 /8 Inch lag screws and 1 /8 Inch drlll bit for <br />1 /4 Inch lag screws. <br />c) clearance holes shall also be drilled for the solid portion <br />of the shank. The clearance hole shall be equal In depth and <br />diameter to the solid portion of the shank. <br />d) the threoded portion of the lag screw shall be inserted in <br />l ts lead hole by turning with a wrench ond not by driving with a <br />hammer or other blunt object. <br />e) soap or other lubricant shall be used on the lag screws or in <br />the lead holes for ease of Installation and to prevent damage to <br />the lag screw. <br />5. Wood screws used to attach anchor side plates shall be installed <br />as follows: <br />a) wood screws shall be located at the center of the plate <br />thickness and shall penetrate the sill plate a minimum of ~ inches. <br />b) lead holes shall be pre-drilled for the threaded portion of <br />the screw. the pre-drill diameter for the lead hole shall be about <br />7 /8 th of the diameter of the screw at the root of the thread <br />(mimimum solid diameter). Use 1 /8 inch for #14 screws.) <br />c) clecirence holes shall also be drilled for solid/aortlon of <br />the shank. The clearance hole shall be about 7 8ths of the <br />diameter of the solid portion of the shank. Use a 3/16 Inch <br />drill bit for # 14 sa-ews. <br />d) the threaded portion of the wood sa-ew shall be Inserted In <br />I ts lead hole by turning with a wrench and not by driving with <br />a hammer or other blunt object. <br />e) soap or other lubricant shall be used on the wood screws or <br />In the lead holes for ease of lnstallatlon and to prevent <br />damage to the wood screw. <br />6. Shims may be used on sill plates for single plate anchors <br />when the space exceed 3/16'" and Is less than 3/4'". <br />Shim requirements greeter than 3 /4 Inch shall use two plate <br />or curved plate connections unless otherwise approved. <br />I. BRACING, FRAMING ANCHORS & VENTILATION <br />1. Framing members or 2X4 blocklng shall be provided at the edge of <br />all wood structural sheathing. <br />2. Nans or screws shall be centered In the framing member or <br />blocking e,ccept at adjoining panel edges where a minimum 1 /2 <br />inch edge distance shcill be maintained. <br />3. Panel j oints shall normally occur on the centerline of studs <br />but may occur on the joint of double studs when these studs ore <br />nailed with 16d common 8 Inches on center. <br />4. Panel j oints shall maintain o 1 /8 inch separation between <br />panels for expansion. <br />5. Panels may be oriented horizontally or vertically. <br />6. Nons shall be driven flush but shall not fracture the <br />surface of the sheathing. When a nail fractures the sheathing it <br />shall be left In place and not counted as port of the required <br />nailing. A new nan shall be driven flush to the surface within <br />2 inches of the discounted nail. <br />7. Framing anchors shall be Installed with their long dimension <br />horizontal and with all of the nail holes filled with nails or <br />approved wood screws. Drywall screws shall not be used. <br />e. Existing ventllotlon must be maintained and not covered by <br />the wall bracing. Where obstructions such as vent holes or <br />mechanical utllltles cannot be avoided ln the panel width, the <br />required panel width shall be increased by the length of the <br />obstruction or a minimum of one stud spacing, whichever ls <br />greeter up to, but not exceeding the full length of the <br />cripple wall. <br />I ---EX ISTIN G STUD WAU. <br />NEW a?PPLE WALL CONSTRUCTION IS NOT <br />PERMITIED WlniOUT AN DIGINEERED DESIGN. <br />USE A FULL HEIGHT CONCRElE S'IEM WALL <br />WITH A PRESSURE TREATED SILL PLATE <br />IF VDU REMOVE lHE EXISTING CRPPLE WALL <br />'b <br />{ <br />Q <br />/ f - - -EXISTING FLOOR CONS"TRUCTION <br />EXISTING CRIPPLE WAU. -- - - - . . <br />NEW 2X4 D .F. #2 BLOCKING \lt1lli - - - <br />4-10d COMMON NAILS ONLY <br />NAILS AT EACH BLOCK TO THE <br />EXISTING SIU. PLATE <br />1 /18 INCH M AXIMUM---..... <br />OVERSIZED HOLE DRIU.ED <br />IN SIU. PLATE <br />NEW 4 \ INCH FRAMING ANCHORS SPACED <br />ER TABLE \lt1lli 1 2- Bd INCH COMMON <br />NAILS OR f6 FLAT HEAD WOOD SCREWS <br />NEW FOUNDATION ANCHOR 801. TS AND <br />PLATE WASHERS PER MA TERI AL NOTES <br />,;--NIE\J 15/32 INCH STRUCTURAL <br />PANEL SHEATHING <br />SIU. P LATE----..l l - - LO C A T E BOLT IN <br />CENTER OF PLATE <br />"7"':J,....-114 REBAR CONTINUOUS <br />EXISTING GROUND LEVEL <br />1:1 ' <br />~ <br />I< <br />15z <br />© <br />i!d · <br />0 : I l l ·, \.!) " · <br />o!!!.!... <br />lL , , · , .a,. ;· .· ,, ~ , - ~ <br />~ i -~ · ' · :4 : ... · #4 REBAR CONTINUOUS O 48'" O.C. <br />z§!c .r.'\ ~ ··· 4.' . ,··:.M IN, DIMS, <br />:Ew 't7' :IE · · · · . I . <br />A ■ ,. · . : ·: · · : ,. - - - - 3· MIN # OF W F D T <br />'1 ,- - - - - '"= "= < - ,._ _ _ _ _ .,..,..c..,._ !--~~-::_~...cc...:...--J STORIES <br />VERTICAL REINFORCEMENT <br />1/4 0 4 8" o.c. <br />j @ j t - - 1 - - 1 2 - - 6 - - 1 2 - - 6 - 1 <br />I' ,. <br />2 15 7 18 B <br />3 18 B 24 10 <br />1-1/16" TO 1 -1 /2" RADIUS ON SHEAllilNG <br />EDGE, DO NOT SQUARE CUT <br />· .. . <br />··. ·"' -~ . ~-EX ISTIN G <br />· · ' · ·· · FOUNDATION WAU.. . . .. <br />i - - - INCREASE WAil. BRACING LENGlli A DISTANCE <br />EQUAL TO LENGlli OF VENT /HOLES BUT NOT LESS <br />l liAN ONE STUD SPACE <br />FOUNDATION <br />ANCHOR BOLT <br />4 C R I P P LE W A LL B R A C I N G - O P E N I N G R E I N F O R C E M E N T <br />NEW D.F. #2 LUMBER OR 1 \ INCH PLYWOOD <br />BLOCKING TOE-NAIL TO JOISTS \lt1lli 2-Bd <br />COMMON OR BOX NAILS AT EACH END OR <br />END-NAIL \lt1lli 2 - 16d COMMON OR <br />SINKER NAILS lliROUGH EACH JOIST <br />EXISTING <br />RIM JOIST <br />OR NO <br />JOIST <br />BLOCKING <br />NEW D.F. #2 WM BER BLOCKING <br />\lt1lli 1 Od COM MON OR 16d SINKER <br />NAILS AT 4 INCHES ON CENTER TO <br />EXISTING FLOOR JOIST. <br />BRACED PANEL <br />, ..::a1...:..._R_EP_L_A_c_E_M_E_N_T_c_o_N_c_R_ET_E_F_o_o_T_1 _N_G_A_N_D_s_TE_M _ _w _ A _ L _ L _ ~ EXISTING -- 1 <br />c - CRIPPLE <br />EXISTING <br />C RIPPLE-+~ <br />WAU. <br />..J------r <br />NEW 4 \ INCH FRAMING ANCHORS <br />SPACED PER TABLE \lt1lli <br />1 2- 8d X 1~ INCH COMMON NAILS <br />OR f6 X 1 \ FLAT HEAD <br />EXISTING 2 l f - - - - - - . . . <br />SOLE PLATE <br />EXISTING 2X - - - - . . <br />RIM JOIST <br />,, , - - EXISTING STUD WAU. <br />EXISTING FLOORING OVER SIJBFLOOR <br />1 · <br />NEW 2X6 D .F. #2 BLOCKING :-----✓ )=t:j~=~MINIMUM <br />W illi 6-10d COMIION OR 16d <br />SINKER NAILS PER 16 INCHES <br />l --'\,--N E \J 15/32 INCH STRUCT~AL PANEL SHEATHING <br />EXISTING ::i:-----------JCRIPPLE WAU. ---t-1 '. Bd COMMON NAILS AT 4 INCHES O.C. <br />AT SHEATHING EDGES <br />*NEW 2X4 D.F. #2 BLOCKING \lt1lli <br />4-1 Od COMMON NAILS ONLY <br />NAILS AT EACH BLOCK TO l liE <br />EXISTING SIU. PLATE <br />EXISTING GROUND LEVEL----... <br />M AINTAIN l liE M INIMUM CONCRETE EDGE -- - ' <br />DISTANCE REQUIRED BY lliE APPROVAL <br />Bd COMMON NAILS AT 12 INCHES ON CENTER AT <br />STUDS \lt1lli A M INIMUM OF 2 FASTENERS PER STUD <br />M IN. EMBEDMENT REQUIRED <br />BY lliE APPROVAL1- - - - <br />(·) TYP O D ETAILS@ .@ & @ <br />2o. C R I P P LE W A LL S E C T I O N - P A R A L L E L J O I S T S <br />EXISTING 2 l f- - - - - . . . . _ <br />SOLE PLATE <br />EXISTING 2X - - - - . . <br />RIM JOIST <br />NEW 2X4 D .F. #2 BLOCKING <br />BE"TWEEN STUDS \lt1lli 4-10d <br />COMMON OR 16d SINKER NAILS -- - - 1 ' " <br />, , - - EXISTING STUD WAL!. <br />EXISTING FLOORING OVER SIJBFLOOR <br />NEW 4 \ INCH FRAMING ANCHORS SPACED <br />PER TABLE W illi 1 2- 8d X 1 , INCH COMMON <br />NAILS OR f6 X 1 \ FLAT HEAD WOOD SCREWS <br />NEW 1 5/32 INCH S"TRUCTURAL PANEL -- t- = ~ = 1 - - k <br />SHEAllilNG Bd COMMON NAILS AT 4 INCHES <br />NEW 2X4 D .F. #2 BLOCKING NAILED <br />TO l liE EXISTING SIU. PLATE \lt1lli - , <br />4-10d COMMON NAILS ONLY AT <br />EACH BLOCK <br />LOCATE SIU. PLATE ANCHOR <br />IN M IDDLE OF PLATE \lt1Dlli <br />EXISTING GROUND l.E1/EL <br />· <br />O.C. AT SHEAllilNG EDGES <br />d COMMON NAILS AT 12 INCHES ON CENTER AT <br />STUDS \lt1lli A M INIMUM OF 2 FASTENERS PER STUD <br />M IN. EMBEDMENT REQUIRED <br />BY lliE APPROVAL .. · ~ - - - <br />2b C R I P P LE W A LL S E C T I O N - P A R A L L E L J O I S T S <br />EXISTING 2 , . _ - - . . . . . . _ <br />SOLE PLATE <br />EXISTING 2X RIM ----... <br />JOIST OR BLOCKING <br />SEE DETAIL 5 FOR ADDING <br />BLOCKING WHEN M ISSING <br />NEW 1 5/32 INCH S"TRUCTURAL PANEL -,-= = !-l <br />SHEAllilNG <br />NEW 2X4 D .F. #2 BLOCKING NAILED <br />TO THE EXISTING Sill. PLATE WITH ----... <br />4-10d COM MON NAILS ONLY AT <br />EACH BLOCK <br />EXISTING GROUND LE V E L- , <br />M AINTAIN l liE M INIMUM CONCRETE EDGE -- - ' <br />DISTANCE REQUIRED BY lliE APPROVAL <br />·· <br />~- EXISTING STUD WALL <br />EXISTING FLOORING OVER SIJBFLOOR <br />NEW 4 · INCH FRAMING ANCHORS SPACED <br />PER TABLE W illi 1 2- 8d X 1 \ INCH COMMON <br />NAILS OR f6 X 1i, FLAT HEAO WOOD SCREWS <br />Bd COMMON NAILS AT 4 INCHES <br />O.C. AT SHEAllilNG EDGES <br />Bd COMMON NAILS AT 12 INCHES ON CENTER AT <br />STUDS \lt1lli A M INIMUII OF 2 FASTENERS PER STUD <br />M IN. EMBEDMENT REQUIRED <br />BY lliE APPROVAL1- ~ - - <br />C R I P P LE W A LL S E C T I O N - P E R P E N D I C U L A R J O I S T S <br />WAU. NEW 4 \ INCH FRAMING ANCHORS <br />SPACED PER TABLE \lt1lli <br />12- Bd X 1 \ INCH COMMON NAILS <br />WOOD SCREWS <br />OR f6 X 1~ FLAT HEAD WOOD SCREWS <br />NEW 2X4 D .F. #2 BLOCKING <br />BETWEEN STUDS \lt1lli 4-10d <br />COMMON OR 16d SINKER NAILS <br />B LOCKING/FRAMING ANCHOR- <br />MISSING 2X BLOCKING, RIM <br />BLOCKING/FRAMING ANCHOR- <br />PARALLEL JOIST OBSTRUCTION <br />JOIST OR PERPENDICULAR JOIST <br />EXISTING 2 · - - . . . . . . _ <br />SOLE PLATE <br />EXISTING 2 · BLOCKING <br />OR RIM JOIST <br />EXISTING SIU. PLATE -, <br />M INIMUM EDGE DISTANCE <br />PER APPROVAL · ··· -: 4 .. <br />..... : .. <br />EXISTING STUD WAU. <br />NEW 4li, INCH FRAMING ANCHORS <br />SPACED PER TABLE Willi <br />1 2- 8d X 1li, INCH COMMON NAILS <br />_v - O R fa X 1 · FLAT HEAD WOOO SCREWS <br />LAG BOLT PER APPROVAL <br />BOLT PER APPROVAL <br />i - - - - - - A P P R O V E D ANCHOR SIDE PLATE <br />CONCRETE STEM W Ail.--..."1:--:-· ~··!~-- ! ll! ! l~ - - - - - E X P A N S I O N OR ADHESIVE ANCHOR.. ' ·. · .' ..... ... <br />.. ·'!' <br />;!'--..::(__MIN EMBEDMENT AS APPROVED <br />EXISTING GROUND LEVEL FOR ANCHOR TYPE, BUT M UST NOT <br />EXCEED 2 /3 STEM WAU. <br />llilCKNESS FOR EXPANSION ANCHORS <br />® S I LL P LA T E B O L T I N G - N O C R I P P LE W A LL <br />P A R A L L E L O R P E R P E N D I C U LA R J O I S T <br />EXISTING 2x - - - . . . . _ <br />SOLE PLATE <br />EXISTING 2x BLOCKING <br />OR RIM JOIST <br />EXISTING FOUNDATION C O NC RETE--t-,- <br />M INIMUM EDGE DISTANCE <br />PER APPROVAL <br />·. : . ·'. .' <br />EXISTING STUD WALL <br />NEW 4 · INCH FRAMING ANCHORS <br />SPACED PER TABLE \lt1lli <br />1 2- Bd X 1 .. INCH COMIION NAILS <br />OR f6 X 1 · FLAT HEAD WOOD SCREWS <br />./ ' " - - WOOD SCREWS PER APPROVAL <br />r -----APPROVED ANCHOR SIDE PLATE <br />~- - A D H E S I V E OR <br />EXPANSION ANCHORS <br />4 " MIN EMBEDMENT AS APPROVED <br />FOR ANCHOR TYPE. BUT M UST NOT <br />EXCEED 2 /3 STEM WAU. <br />llilCKNESS FOR EXPANSION ANCHORS <br />0 S I LL P LA T E B O L T I N G - T R A P E Z O I D A L F O O T I N G <br />EXISTING 2X <br />SOLE PLATE <br />EXISTING -, . <br />SUBFLOOR <br />NAILING <br />EXISTING SIU. PLATE <br />4" M INIMUM EDGE DISTANCE <br />PER APPROVAL . . . <br />EXISTING STUD WAU. <br />/4 " M AX. SHIM <br />SPACING <br />LAG SCREWS PER APPROVAL <br />· i ---.AP P RO VED ANCHOR SIDE PLATE <br />CONCRETE STEM WAU. -- . . . . . <br />EXISTING GROUND LE'IEL <br />J .-t--·:·,l!im,~·i®----...EXPANSION OR ADHESIVE ANCHOR <br />' <br />4 .. . . .. .' . . . <br />4" MIN EMBEDMENT AS APPROVED <br />FOR ANCHOR TYPE, BUT M UST NOT <br />EXCEED 2 /3 STEM WAU. llilCKNESS <br />FOR EXPANSION ANCHORS <br />A3-4A <br />® S I LL P LA T E B O L T I N G - N O F LO O R J O I S T S <br />P A R A L L E L O R P E R P E N D I C U LA R J O I S T <br />PERPENDICULAR JOISTS <br />NEW D.F. #2 LUMBER OR <br />1 \ INCH PLYWOOD BLOCKING <br />· <br />-- tM I · <br />EXISTING C O NC RETE~',''-,-.~--., <br />..··.:~....... . ..... .··· <br />2 - 3 INCH ·..· ·· <br />'vENTILATION HOLES .; f!J·· <br />CENTERED 1 INCH · · .~ .' ~· <br />CLEAR ABOVE BLOCK ··· ·" · · . . <br />· <br />· <br />.· · '!'·· ·. ·: . ·· <br />' 4 . ... -. <br />ONLY ONE HOLE IS "-.J.!·--~~t-.:..>-'--~REQUIRED FOR WAU.S · <br />\lt1TH STUD HEIGHTS <br />PARALLEL JOISTS NEW 2XB D.F. #2 <br />BLOCKING \lt1lli 6 - <br />1 Od COMMON O 6 <br />INCHES. <br />t - - ~ o _ _~o~__ o ~ . . . . o <br />0 0 0 0 0 0 0 2· <br />---T--r-------------5 ..,d-T-'.,-'r- <br />O · <br />· <br />I O Bd COMMON NAILS <br />1 <br />01 <br />°0 AT 4 INCHES O.C. <br />10 AT SHEA THING <br />I ol EDGES <br />- I 1. I BD COM MON NAILS <br />____ _. o L - - - - - ~ { i -:J o ol_ AOTC 1 ~TINSTUCHESDS <br />0 I I O O O I o lo · ' ------'--.l------ ____ ..,_ ;.i._ M INIMUM 2 NAILS <br />· <br />:- .... ·-. ~ .....,, . . . <br />' .... <br />-~ - + - - . - 1 PER STUD <br />. . , ~ · . 4 EXISTING <br />... · ' .,.: . . ... . ..... <br />CONCRETE <br />··... . .41, ', ........... ... . .. ' .. '. .. . . <br />LESS l liAN 1B INCHES.ANCHORS W illi PLATE <br />WASHER AND NUT PER SCHEDULE <br />9 -12" FROM <br />AU. SIU. <br />PLATE ENDS <br />® <br />9 -12" FROM <br />AU. SIU. <br />PLATE ENDS <br />C R I P P LE W A LL B R A C I N G - I N T E R I O R E LE V A T I O N <br />JOIST PERPENDICULAR TO <br />CRIPPLE WALL <br />EXISTING STUD WAU. <br />EXISTING FLOORING OVER SIJBFLOOR APPROVED ANCHOR <br />SIDE PLATE <br />JOIST PARALLEL TO <br />C RIPPLE WALL <br />EXISTING STUD WAU. <br />EXISTING FLOORING OVER SUBFLOOR <br />EXISTING <br />FLOOR JOIST <br />EXISTING <br />BLOCKING OR <br />RIM JOIST <br />NEW D.F. #2 WMBER OR 1 , INCH PLYWOOD <br />.- . - ~ - ~ - . . - - - \ / BLOCKING TOE NAIL TO JOISTS \lt1lli 2-Bd <br />SPACED PER TABLE LAG SCREWS PER <br />APPROVALCOMMON OR BOX NAILS AT EACH END OR <br />EXISTING END-NAIL \lt1lli 2-16d COMMON OR SINKER · .. . . , . - - ~ . . . , . . . . , - - - . 1 · MIN ·FLOOR NAILS THROUGH EACH JOIST. <br />JOIST 4" IIINIMUII <br />EDGE DISTANCE <br />4 · M INIMUM ,--~-'l-:--..,-..,.,;t:1:::e:::::::S:::-NEW 4 \ INCH FRAMING ANCHOR SPACED <br />EDGE DISTANCE 1 . ,..PER TABLE Willi 1 2- 8d X 1 \ INCH <br />FOR FUU. LOAD " , · ' COMMON NAILS OR f6 X 1 \ FLAT <br />,. . . ·_'."'. l<.,~~....lJ:'.:·'7"'.···:··~··:··-·,1-EXPANSION OR <br />,11 4· , · I!, . . , . . c ADHESIVE ANCHORS <br />· ·· · <Ill · ': · ,; : .· : · .· · : · ;. · : ·_.3-~ EXISTING CONCRETE <br />· · · · · · · · ··· · STE" w·u. <br />VALUE PER " ·, ·.~· · HEAD WOOD SCREWS <br />. : ·· '·. .... .. · . ,.. .. "' ~ <br />.· ~ , I l l · · .. <br />APPROVAL , · NEW ADHESIVE OR EXPANSION ANCHOR AND <br />'~ :·.PLATE WASHER PER TABLE <br />. . . <br />·.: -··.·: ····:· ·. . . · .. .,·: .... ·..... '· : . ..... <br />EXISTING CONCRETE <br />STEM WAil. <br />. . . : . ·. <br />·. : . ;,' · .NEW 2 X 6 PRESSURE "TREATED D.F. PLATE <br />B IN. M INIMUM CLEARANCE TO SOIL <br />EXISTING CONCRETE <br />FOOTING <br />. . . ... . . <br />·· ' . . . · . ·. ·1 · · . . .. · ! .. <br />4· MIN EMBEDMENT AS APPROVED <br />FOR ANCHOR TYPE, BUT M UST NOT <br />EXCEED 2 /3 STEM WAil. <br />A N C H O R A G E F O R J O I S T S S U P P O R T E D <br />O N C O N C R E T E <br />·llilCKNESS FOR EXPANSION ANCHORS <br />A N C H O R A G E F O R J O I S T S <br />O N C O N C R E T E <br />S U P P O R T E D <br />. / ' " - EXISTING STUD WAU. <br />STEEL SPLICE <br />PLATE <br />' I I I I <br />. <br />0.036 IN. GALV. STEEL <br />(20 GALVANI ED GAGE) <br />0 <br />0 <br />o , <br />' 0 O 0 '0 0 0 <br />0 <br />0 <br />0 <br />SIX- 8d NAILS <br />EACH SIDE <br />I <br />EXISTING RIM JOIST OR <br />BLOCKING OR NEW D .F. #2 <br />BLOCKING \lt1lli 8d TOE <br />NAILS AT 6 INCHES O.C. <br />TO TOP PLATE <br />~- FLOORING OVER SUBFLOOR <br />S TU D / <br />; SINGLE TOP I· G"'· I <br />3 /8 INCH M INIMUM <br />EDGE DISTANCE (TYP.) <br />8d COMMON NAILS <br />AT 4" ON CENTER <br />NEW 1 5/32 INCH S"TRUCTURAL PANEL <br />SHEA l lilNG - - - 1 <br />Bd COMMON NAILS AT 4 INCH ON <br />CENTER AU. EDGES AND 12 INCH ON <br />CENTER EACH INTERMEDIATE STUD <br />WIN 2 NAILS PER STUDS <br />1 /2 FLOOR JOIST OEPlli <br />TOP SINGLE PLATE <br />CRIPPLE STUD WAU. <br />CONCRETE STEM WALL <br />· <br />PLATE <br />· u.,." <br />SINGLE TOP PLATE <br />STEEL SPLICE PLATE <br />(TOP VIEW) <br />S I N G LE T O P P LA T E S P LI C E <br />M INIMUM 0.058 IN. llilCK <br />16 GAGE BY 1\INCH <br />GALVANIZED M ETAL S"TRAP <br />AT EACH PLATE SPLICE <br />" · · " " · I · ,. ,. · · <br />18 GA. STEEL <br />>A> <br />INSTALL S'TRAP SIX 16d NAILS SIX Bd NAILS <br />OVER WALL BRACNG AT EACH ENO AT EACH END <br />M -IERE OCCt.lRS <br />STUD~ .L<,.L <br />7 <br />PROVIDE A WEAlliER-RESISTIVE <br />BARRIER TO PROTECT l liE SHEA llilNG. <br />EXTERIOR LA l l i FOR CEMENT PLASTER <br />REQUIRES TWO LAYERS OF GRADE D <br />PAPER OVER l liE SHEAllilNG. <br />..M AINTAIN l liE M INIMUM CONCRETE <br />EDCE DISTANCE REQUIRED <br />.L\...L--...sTUD <br />G)M ETAL STRAP @ RETROAI TENSION TIE <br />BY lliE APPROVAL <br />C R I P P LE W A LL B R A C I N G W I TH P LY W O O D <br />O N E X T E R I O R F A C E O F C R I P P LE S T U D S <br />NEW 2X CRIPPLE STUD NAILED TO <br />EXISTING STUD \lt1lli 1 Od COM I I ON <br />2X4X12 WOOD <br />BL.OCKl'G <br />I I I I <br />;S l~ E TOP <br />STUD,..-PLATE <br />2X4X12 <br />WOOD <br />BLO ING <br />0 0 <br />0 0 0 0 <br />0 0 0 0 <br />i - - - - ; 1 2 · ~ - - - - i <br />SING TOP <br />PLATE <br />NAILS AT 4" ON CENTER AT WOOD <br />S"TRUCTURAL PANEL JOIST 3 NAILS M IN. <br />EXISTING STUD 2" MIN OR PROVIDE <br />NEW STUD AT PANEL JOINlS <br />u.,.(TOP VIEW) <br />I I <br />1 /2" MIN--J.,f .f..J,-1/2" MIN <br />,i,,l,..1 /B " MIN 1 /2" MIN--,1..,f .f..,l,-1/2" MIN <br />,1,,1,.. 1 /8 " MIN <br />@ WOOD BLOCKING <br />A LT E R N A T I V E S TO S I N G LE <br />TO P P LA T E S P LI C E <br />~ V E R T I C A L S P LI C E v A T D O U B LE S T U D <br />~ V E R T I C A L S P LI C E v A T S I N G LE S T U D <br />SUMMARY OF MINIMUM PRESCRIPTIVE REQUIREMENTS <br />NUMBER OF STRUCTURAL WOOD SILL PLATE <br />STORIES1 ABOVE PANEL CRIPPLE ANCHOR FRAMING ANCHOR JOIST <br />WALL BRACING SIZE AND BLOCKING 7 <br />CRIPPLE WALL REQUIRE~ENTS2 SPACING3-M <br />EACH END AND 1 /2 INCH AT 6 <br />ONE1 NOT LESS THAN 3 2 INCHES ON ALTERNATE <br />50% OF THE WALL FEET ON CENTER M AXIMUM JOISTS <br />LENGTH CENTER MAX <br />EACH END AND AL lERNAlE <br />TWO'NOT LESS THAN 1 /2 INCH AT 4 24 INCHES ON JOISTS AND <br />70% OF THE WALL FEET ON CENTER M AXIMUM EVERY JOIST <br />LENGTH CENTER MAX8 ABOVE WALL <br />BRACING <br />THREE1 100% OF THE 5 /8 INCH AT 4 16 INCHES ON <br />WALL LENGTH FEET ON CENTER M AXIMUM ALL JOISTS <br />CENTER MAX 6 <br />REQUIRED BRACING FOR ONE STORY <br />14' O'" -18' O"- <br />·6"·- ~ I 4 '-0 " 1 3 '- · 4'-0'" 6", .·1 · I · I ·r· <br />L <D -. -'\(~lo ., <br />.I I- .. <br />OlliER OBS"TRUCllONS , <br />· WHICH DO NOT AU.OW <br />0 PANEL TO EXTEND TOICORNER.·~~I-.·0I"~11,\11,\1~ 4 '-0 " <br />' - '-'c <br />~ <br />BRACING I··0 (TYP.)I;,. <br />~ <br />( ~ <br />'- ' <br />4' O" 10· o· <br />~NOTES: <br />I;...1. BRACING SHOWN IS FOR A ONE-STORY <br />HOUSE W illi CRIPPLE WALL HEIGHT OF <br />14" OR LESS IN HEIGHT. <br />2. INDIVIDUAL PANEL LENGlliS SHAU. BE <br />TWO TIMES l liE HEIGHT OF l liE CRIPPLE <br />STUD WAil. BUT NOT LESS l liAN 4 '-0 ". <br />·... <br />I <br />" <br />FOUNDATION OUTLINE ( ~·(TYP.)., <br />I <br />°' <br />·( ~ 'b0 <br />I I ,....,.,. ;,. - '- ' <br />·"' <br />6" a·6 " <br />12·-o·8 '-0 " <br />3 2'-0 " <br />REQUIRED BRACING FOR lliREE STORY <br />S A M P LE P LA N <br />1. lliESE STANDARDS DO NOT APPLY TO ONE OR TWO STORY BUILDINGS Willi CRIPPLE WALLS <br />GREATER l liAN 48 INCHES IN HEIGHT OR TO lliREE STORY BUILDINGS 'M lli CRIPPLE WALL <br />STUDS GREATER l liAN 14 INCHES. <br />2. lliE WALL BRACING LENGlli SHAU. BE AT LEAST 48 INCHES IN \lt1Dlli OR TWO TIMES l liE <br />HEIGHT OF l liE CRIPPLE WALL, WHICHEVER IS GREATER. WAU. BRACING IS REQUIRED AT ALL <br />EXTERIOR WAU.S. <br />3. lliE PLATE WASHERS FOR USE \lt1lli ADHESIVE OR EXPANSION ANCHORS ON WOOD SHALL BE <br />3-INCH BY J-INCH BY 0.229" M IN. <br />4. EXISTING SIU. PLATE ANCHOR BOL 1S CAST IN CONCRETE AND IS IN SOUND CONDITION SHAU. <br />BE PERMITTED TO PROVIDE AU. OR A PORTION OF l liE SIU. PLATE CONNECTION <br />REQUIREMENT IF l liE ANCHOR BOLT DIAMETER AND SPACING M EETS OR EXCEEDS l liE TABLE <br />REQUIREMENTS. A NEW PLATE WASHER CONFORIIING TO FOOlNOTE 3 IS INSTALLED AND l liE <br />SIU. PLATE IS CONNECTED TO A SNUG TIGHT CONDITION UNDER l liE TORQUE TEST <br />REQUIREMENT. <br />5. ANCHOR SIDE PLATES SHAU. BE PERMITTED TO SUBSTITUTE FOR ADHESIVE OR EXPANSION <br />ANCHORS WHEN CONDITIONS PREVENT ANCHOR INSTALLATION VERTICAU.Y THROUGH l liE SIU. <br />PLATE. ANCHOR SIDE PLATES SHALL BE SPACED l liE SAME AS ADHESIVE OR EXPANSION <br />ANCHORS PER SECTION E REQUIREMENTS. ONLY ONE ANCHOR SIDE PLATE SHAU. BE <br />REQUIRED ON INDIVIDUAL PIECES OF SIU. PLATE LESS l liAN 32 INCHES IN LENGlli. <br />6. TWO STORY BUILDINGS MAY SUBSTITUTE 5 /8 INCH ANCHORS AT A M AXIMUM OF 6 FEET ON <br />CENTER AND lliREE STORY BUILDINGS MAY SUBSTITUTE 1 /2 INCH ANCHORS AT A M AXIMUM <br />OF 2 FEET B INCHES ON CENTER. <br />7. EXISTING 2 INCH NOMINAL llilCKNESS JOIST BLOCKING SHAU. BE PERMITTED TO M EET l lilS <br />REQUIREMENT. NEW BLOCKING MAY BE EllliER 2 INCH NOMINAL DIMENSIONED WMBER OR 1 <br />PLYWOOD. <br />1~ <br />·'- 0 " <br />n \ <br />' - ' <br />· 0I;...(~ <br />6" <br />1 2'-0" <br />·<D <br />'bI;,. <br />· <br />~0II~" <br />'bI;,. <br />lo <br />NOTE: <br />THIS STANDARD PLAN DOES NOT APPLY TO <br />THE BUILDINGS OR ELEMENTS THEREOF USTED <br />BELOW . <br />THESE BUILDINGS OR ELEMENTS REQUIRE <br />ANALYSIS BY A UCENSED ENGINEER OR <br />ARCHITECT. <br />1. BUILDINGS v.1TH A LATERAL-FORCE- <br />RESISTING SYSTEM USING POLES OR <br />COLUMNS EMBEDDED IN THE GROUND . <br />2. CRIPPLE WALLS THAT EXCEED 4 FEET IN <br />HEIGHT. <br />3. BUILDINGS EXCEEDING THREE STORIES IN <br />HEIGHT AND ANY THREE-STORY BUILDING <br />v.1TH CRIPPLE WALL STUDS EXCEEDING 14 <br />INCHES IN HEIGHT. <br />4. BUILDINGS v.1TH M ORE THAN 4 DWELUNG <br />UNITS OR 4 GUEST ROOMS. <br />5. BUILDINGS, OR PORTIONS THEREOF, <br />CONSTRUCTED ON A CONCRETE SLAB ON <br />GRADE OR CONSTRUCTED ON OR INTO A <br />SLOPE STEEPER THAN ONE UNIT VERTICAL <br />IN 3 UNITS HORIZONTAL <br />6. BUILDINGS WHERE THE SUPERINTENDENT <br />OF BUILDING DETERMINES THAT <br />CONDITIONS EXIST THAT ARE BEYOND THE <br />SCOPE OF THE REQUIREMENTS OF THIS <br />PLAN. <br />7. BUILDINGS THAT LACK CONTINUOUS <br />FOOTINGS. <br />B. BUILDINGS V.,TH REINFORCED OR <br />UNREINFORCED M ASONRY OR STONE <br />FOUNDATIONS. <br />(/) <br />z <br />D <br />f - , <br />( /) <br />f - , <br />>w <br />~ <br />'° ___, <br />0 <br />(U <br />"- <br />(Y) <br />0 <br />"-Ln <br />0 <br />G:z <br />~ <br />>< <br />\\ \ <br />:z <br />r::=iw <br />> <br />D <br />~ <br />Q__ <br />Q__ <br /><I <br />00 <br />0 <br />\ \ <br />:::J <br /><[ <br />w"':::J"' <br />l'.lz <br />H <br />"'wwz <br />H <br />l'.lzw <br />w <br />I <br />f-- <br />"- <br />□ <br />"-w <br />H <br />Iu <br />H <br />"-w <br />I <br />(I) <br />< [ <br />" < [ <br />"- <br />H <br />'5 C ) <br />~:z==s <br />D:z< <br />V \ <br />\ <br />\ \ \ <br />\ <br />>-1 -wu.. <br /><( <br />CJ) <br />0z <br /><( <br />(9 <br />z-0 <br />..J-::Jco <br />u.. <br />0 <br />1 -zw <br />~ <br />l -a: <br /><( <br />a..w <br />0 <br />::J <br />< [ <br />w"'::J <br />"'"' z <br />H <br />"'wwz <br />H <br />"'zw <br />w <br />I <br />f-- <br />"- <br />□ <br />"-w <br />H <br />Iu <br />f--z <br />< [ <br />f--"'H <br />"' "'<[ <br />_ J <br />_ J <br />H <br />"'zw <br />', ' <br />The Simpson Strong-Tie® Titen HD® Screw Anchor <br />2501 N Santiago St <br />4/14/2025