Laserfiche WebLink
The Enphase IQ Load Controller, when used in <br />conjunction with the IQ System Controller, enables <br />control of up to 2 loads running 240VAC L-L or <br />shedding of up to 2 solar circuits when operating <br />in an off-grid mode with the Enphase energy <br />management system. <br />The IQ Load Controller can also be used for <br />controlling 4 loads running 120VAC L-L. <br />Up to 2 IQ Load Controllers can be integrated with <br />each IQ System Controller on a site. <br />Enphase <br />IQ Load Controller <br />To learn more about Enphase offerings, visit enphase.com <br />Data Sheet <br />Enphase Ensemble Energy Management System <br />Region: AMERICAS <br />Powerful <br />• Control up to 2, 36A resistive loads or 3HP/25A inductive <br />loads running at 240VAC or 4 loads running at 120VAC <br />• Shed up to 2 excess IQ6, IQ7, M215 or M250 solar branch <br />circuits(up to 32A each) to maintain Solar-To-Storage <br />ratio when off-grid <br />• Prioritize essential appliances during a grid outage to <br />optimize energy consumption and prolong battery life <br />manually control loads from the Enphase App <br />Simple <br />• A complete solution for use with the IQ System <br />Controller’s load control feature <br />• DIN rail mounted components enable easy installation <br />and servicing <br />Reliable <br />• Designed for indoor or outdoor installations <br />• 5 years warranty <br />• Durable NEMA 4X Enclosure <br />To learn more about Enphase offerings, visit enphase.com <br />© 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ System Controller, Enphase IQ Load Controller, Enphase Enphase <br />App, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 01-06-2022 <br />IQ Load Controller for use with IQ System Controller’s auxiliary contacts to shed non-essential loads or <br />M-series, IQ series microinverters <br />DC Power Supply input voltage 120Vac <br />DC Power Supply input Current rating 12A <br />Total loads controlled 2 loads running at 240Vac or 4 loads at 120Vac <br />Max load controlled 36A resistive, 25A inductive for dedicated loads, 32A resistive for branch circuits with 2 or more loads <br />Ambient temperature range -25 to 40 °C <br />Dimensions (WxHxD)12.58 x 14.58 x 5.96 (in) <br />Weight 6.61 (lbs) <br />Cooling Natural Convection <br />Enclosure Outdoor, NEMA type 4X, polycarbonate construction <br />Contactor • Line/Load power terminals <br />• <br />14-8AWG <br />Power Supply • 120V L-N input terminals <br />• <br />14-12AWG <br />Ground terminal block 24-6AWG <br />Neutral terminal block 24-6AWG <br />Compliance UL1741 <br />Limited Warranty 5 years <br />Enphase IQ Load Controller <br />3918 S Timber St- <br />2017707802/23/23