Laserfiche WebLink
V E C O <br />d e s i g n - s t u d i o <br />SHEET: <br />JOB No: <br />DATE: <br />DRAWN BY: <br />PLAN: <br />PHONE: <br />JOB SITE: <br />PROJECT NAME: <br />REVISION:BY: <br />VASQUEZ <br />RESIDENCE <br />23-017 <br />06-21-2024 <br />S.V <br />714-713-3124 <br />627, 627 UNIT 2 S. SHELTON. ST. <br />SANTA ANA, CA 92703 <br />d e s i g n e r <br />O s c a r V e g a <br />C e 1 4 - 4 -1 2 4 <br />O i e 3 1 - 2 3 -3 5 <br />i n o e o d e s i g n s .o <br />5 3 4 C O A V E . <br />A A E C A 2 5 <br />APPROVED BY :O.V. <br />S-1.1 <br />WOOD FRAME <br />PRESCRIPTIVE <br />P/BC 2023-004 <br />________________________________________________________________ <br />NOTE: APPLIES TO PANELS 24” OR WIDER (T- <br />ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO <br />OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS <br />R503.2.1.1(1)) <br />SHEATHING GRADES <br />PANEL SPAN RATING <br />Roof/Floor Span <br />24/0 <br />24/16 <br />32/16 <br />40/20 <br />48/24 <br />MINIMUM <br />PANEL <br />THICKNESS <br />(INCHES) <br />3/8 <br />7/16 <br />15/32, 1/2 <br />19/32, 5/8 <br />23/32, 3/4 <br />CONNECTION <br />Roof <br />Blocking between joists or rafters to top plate <br />Ceiling joist to plate <br />Ceiling Joist not attached to parallel rafter, laps over partitions <br />Collar tie rafter, face nail or 1 ¼” 20-gage ridge strap <br />Rafter or roof truss to plate <br />Roof rafters to ridge, valley or hip rafters or roof rafter to minimum <br />2” ridge beam: <br />Stud to Stud (not braced wall panels) <br />Stud to stud and abutting studs at intersecting wall corners (at <br />braced wall panels) <br />Abutting Studs at intersecting wall corners, face nail <br />Built –up header (2” to 2” header with ½” spacer) <br />Continuous header to stud <br />Top plate to top plate <br />Double top plate splice <br />Bottom plate to joist, rim joist, band joist or blocking (not at braced <br />wall panels) <br />Bottom plate to joist, rim joist, band joist or blocking (at braced <br />wall panel) <br />Top or bottom plate to stud <br />4-8d box (2-1/2” x 0.113”) <br />4-8d box (2-1/2” x 0.113”) <br />4-10d box (3” x 0.128”) <br />4-10d box (3” x 0.128”) <br />3-16d box nails (3-1/2” x 0.135”) or <br />3-10d common nails (3” x 0.148”) <br />4-16d box (3-1/2” x 0.135”), or <br />3-10d common (3-1/2 ”x 0.148”) <br />3-16d box (3-1/2” x 0.135”), or <br />2-16d common (3-1/2” x 0.162”) <br />Wall <br />16d common (3-1/2” x 0.162”) <br />10d box (3” x 0.128”) <br />16d box (3-1/2” x 0.135”) <br />16d common (3-1/2” x 0.162”) <br />16d (3-1/2” x 0.135)” <br />16d common (3-1/2” x 0.162”) <br />16d box (3-1/2” x 0.135”) <br />5-8d box (2-1/2” x 0.113”) <br />4 8d common (2-1/2” x 0.131”) <br />16 common (3-1/2 ” x 0.162”) <br />10d box (3” x 0.128”) <br />8-16d (3-1/2” x 0.135”) <br />16d common (3-1/2” x 0.162”) <br />16d box (3-1/2” x 0.135)” <br />3-16d box (3-1/2” x 0.135”), or <br />2-16d common (3-1/2” x 0.162”) <br />4-8d box (2-1/2” x 0.113”), or <br />3-16d box (3-1/2”x 0.135”), or <br />4-8d common (2-1/2” x 0.131)” <br />3-16d box (3-1/2” x 0.135”), or <br />2-16d common (3 ½” x 0.135”), or <br />2-10d (3” x 0.162”), or <br />3-10d box (3” x 0.128”) <br />Top plates, lap at corners and intersections <br />Joist to sill, top plate or girder <br />Rim Joist, band joist or blocking to sill or top plate (roof <br />applications also) <br />Band or rim joist to joist <br />3-10d box (3” x 0.128”), or <br />2-16d common (3 1/2” x 0.162”) <br />Floor <br />4-8d box (2-1/2” x 0.113”), or <br />3-8d common (2-1/2” x 0.131), or <br />3-10d box (3” x 0.128”) <br />8d box (2-1/2” x 0.113”) <br />8d common (2-1/2” x 0.131”), or <br />10d box (3” x 0.128”) <br />3-16d common (3-1/2” x 0.162”), or <br />4-10d box (3” x 0.128”) <br />20d common (4” x 0.192”), or <br />10d box (3” x 0.128”), or <br />Built-up girders and beams, 2-inch lumber layers <br />AND: <br />2-20d common (4” x 0.192”), or <br />3-10d box (3” x 0.128”), <br />Ledger strip supporting joists or rafters <br />Bridging to Joist <br />4-16d box (3-1/2 ”x 0.135”), or <br />3-16d common (3-1/2” x 0.162), or <br />4-10d box (3” x 0.128”) <br />2-10d (3” x 0.128”) <br />Toenail <br />4” o.c. <br />6” o.c. <br />End nail <br />Nail each layer as follows: 32” o.c. at <br />top and bottom and staggered. <br />24” o.c. face nail at top and bottom <br />staggered on opposite sides <br />Face nail at ends and at each splice <br />At each joist or rafter, face nail <br />Each end, toe nail <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, <br />will provide reasonable accommodation to ensure equal access to its programs, services and activities. <br />Page 5 of 9 <br />24” o.c. face nail <br />16” o.c. face nail <br />12” o.c. face nail <br />16” o.c. face nail <br />12” o.c. <br />16” o.c. each edge face nail <br />12” o.c. each edge face nail <br />Toe nail <br />Toe nail <br />16” o.c. face nail <br />12” o.c. face nail <br />Face nail on each side of end joint <br />(minimum 24” lap splice length each <br />side of joint <br />16” o.c. face nail <br />12” o.c. face nail <br />3 each 16” o.c. face nail <br />2 each 16” o.c. face nail <br />toe nail <br />End nail <br />End nail <br />Face nail <br />Toe nail <br />Toe nail <br />Face nail <br />Face nail <br />2 toe nails on one side and 1 toe nail <br />on opposite side of each rafter or <br />truss <br />Toe nail <br />End nail <br />24 <br />24 <br />32 <br />40 <br />48 <br />EDGE SUPPORT <br />ROOF <br />MAXIMUM SPAN (INCHES) <br />NO EDGE <br />SUPPORT <br />20 <br />24 <br />28 <br />32 <br />36 <br />FASTENING <br />LOADS (PSF) <br />TOTAL LOAD LIVE LOAD <br />40 <br />50 <br />40 <br />40 <br />45 <br />30 <br />40 <br />30 <br />30 <br />35 <br />REMARKS <br />FLOOR <br />MAX. SPAN (INCHES) <br />Panel edges with <br />tongue and groove <br />joints or with blocking <br />16 <br />16 <br />20 <br />24 <br />P/BC 2023-004 <br />________________________________________________________________ <br />D/3 MAX. <br />5/8" <br />MIN. <br />D/3 MAX. <br />25% MAX.40% MAX. <br />EXTERIOR WALLS AND <br />BEARING PARTITIONS <br />NOTCHING & BORING RAFTERS, CEILING JOISTS AND FLOOR JOISTS <br />(NOTCHING NOT PERMITTED IN MIDDLE 1/3 JOIST SPAN) <br />(HOLES SHALL NOT BE LOCATED WITHIN 2 IN OF A NOTCH) <br />3:12 TO 4:12 SLOPE W/ 2-LAYERS TYPE 15 FELT <br />4:12 OR GREATER SLOPE W/ 1-LAYER TYPE 15 FELT <br />20 GA.x 1-1/4" <br />STRAP @48" O.C. <br />2-16d EACH SIDE <br />ROOF SHEATHING <br />ROOF RAFTER <br />B.N. 8d@6" OC <br />ROOF RAFTER <br />2X BLOCKING <br />2X ROOF RAFTER <br />2 X RIDGE BOARD-DEEPER THAN <br />CUT END OF ROOF RAFTER <br />ROOF SLOPE-COMP SHINGLES (R905.2) <br />15/32" WOOD STRUCTURAL PANEL <br />W/8d @ 6"/6"/12"(COMMON NAILS) <br />EDGE NAIL <br />B.N. 8d@6" OC <br />RAFTER TIE CONNECTION <br />(SEE PAGE 4) <br />CEILING JOIST <br />EDGE NAIL EDGE NAIL <br />UPLIFT FRAMING CLIP PER TABLE R802.11 <br />2X BLOCKING W/ FRAMING <br />ANCHOR @ EACH BLOCKING <br />BRACED WALL PANEL (SEE PAGE 6) <br />PERPENDICULAR <br />TO ROOF RAFTERS <br />INTERIOR SHEAR WALL AT ATTIC <br />ENGINEERED DESIGNED REQUIRED FOR CONNECTION, <br />RAFTER SPAN (SEE PAGE 3) <br />WHEN PURLIN USED TO REDUCE RAFTER SPAN 2X RIDGE BOARD <br />2X ROOF RAFTERS <br />12 3 MIN. SLOPE <br />NAIL TO JOIST <br />2X SOLID BLOCKING <br />2X DOUBLE TOP PLATE <br />2X STUDS <br />BRACED RAFTER CONSTRUCTION (R802.5.1) <br />HEADER (SEE PAGE 3 FOR SPAN) <br />SOLID BLKG. @ ALL <br />UNSUPPORTED <br />PLYWOOD EDGES <br />CEILING JOISTS (SEE PAGE 3) <br />AT CEILING JOIST SPLICE PROVIDE <br />NAILS PER RAFTER TIE CONNECTIONS (SEE PAGE 3) <br />BEARING PARTITION / INTERIOR SHEAR WALL <br />CONT. DOUBLE TOP PLATE <br />PARALLEL TO <br />ROOF RAFTERS <br />GABLE SUPPORT <br />2X CEILING JOIST <br />RIDGE (R802.3) NAILS (TABLE R602.3(1)) <br />EDGE NAIL <br />EDGE NAIL <br />2X BLOCKING <br />W/ FRAMING <br />ANCHOR EDGE NAIL <br />EDGE NAILROOF RAFTER 2X SLOPED <br />ROOF RAFTER <br />2X BLOCKING <br />2X4 @ 4' O.C. <br />3- 10d NAILS <br />40% MAX.60% MAX. <br />NON-BEARING PARTITIONS <br />EXTERIOR WALLS AND BEARING WALLS MAY HAVE BORED HOLES BETWEEN <br />40 AND 60 PERCENT WHEN STUD IS DOUBLED AND NOT MORE THAN TWO <br />SUCCESSIVE DOUBLE STUDS ARE BORED (R502.8, R802.7.1 R602.6) <br />B.N. 8d@6" OC <br />5/8" <br />MIN. <br />HEADER <br />(SEE PAGE 3 FOR SPAN) <br />2X SILL PLATE <br />ANCHOR BOLTS <br />MIN 1/2" DIA. x 10", <br />7" EMBEDMENT <br />2 #4 TOP & BOTTOM. <br />WALL FRAMING <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, <br />will provide reasonable accommodation to ensure equal access to its programs, services and activities. <br />Page 6 of 9 <br />MIN. 2 ANCHOR BOLTS PER BRACED <br />WALL PANEL, MAX 12" & MIN. 4" FROM <br />EACH END OF THE PLATE SECTION <br />HOLD DOWN EACH SIDE OF PANEL (1800# MIN. CAPACITY) PER PAGE 6 <br />THICKEN FOOTING AS REQUIRED FOR BOLT EMBEDMENT DEPTH <br />D/ <br />6 <br /> <br />M <br />A <br />X <br />. <br />2" <br /> <br />M <br />I <br />N <br />. <br />2" <br /> <br />M <br />I <br />N <br />. <br />D/ <br />6 <br /> <br />M <br />A <br />X <br />. <br />1/ <br />3 <br /> <br />' <br />D <br />' <br />'D <br />' <br />'D <br />' <br />D/ <br />4 <br /> <br />M <br />A <br />X <br />. <br />'D <br />' <br />D/ <br />4 <br /> <br />M <br />A <br />X <br />. <br />'D <br />' <br />10 <br />' <br /> <br />M <br />A <br />X <br />. <br />P/BC 2023-004 <br />________________________________________________________________ <br />c1 <br />48" MIN. FOR METHOD WSP <br />AND <br />96" MIN. FOR GB <br />(a,d) <br />& PCP <br />(c) <br />(b,d) <br />SEE NOTE 1. <br />NOTES: <br />1.BRACED WALL LINES AT EXTERIOR WALLS SHALL HAVE A BRACED WALL <br />PANEL LOCATED AT EACH END OF THE BRACED WALL LINE. <br />EXCEPTION: FOR METHOD WSP , THE BRACED WALL PANEL SHALL BE <br />PERMITTED TO BEGIN NO MORE THAN 10 FEET FROM EACH END OF THE <br />BRACED WALL LINE PROVIDED: <br />(c) <br />UP TO 10' <br />NO PENETRATIONS <br />PERMITTED IN BRACED <br />WALL PANELS A <br />METHOD WSP <br />BRACING ONLY <br />(c) <br />OR <br />BWL BWL BWL <br />B <br />4' MAX OFFSET <br />4' MAX OFFSET <br />DESIGNATED BRACED <br />WALL LINE (BWL) <br />24"24"A MIN. 24" PANEL IS APPLIED TO EACH SIDE. <br />THIS 24" WIDE PANEL DOES NOT COUNT AS <br />BRACING <br />UP TO 10' <br />METHOD WSP <br />BRACING ONLY <br />BWL 1800 LBF HOLD-DOWN DEVICES REQUIRED AT <br />THE ENDS OF EACH BRACED WALL PANEL <br />20'-0" MAX. <br />BRACED WALL LINE LENGTH <br />BRACED WALL PANEL REQUIREMENTS <br />2. MIXING BRACING METHODS WITHIN A BRACED WALL LINE IS NOT PERMITTED. <br />3.INTERIOR BRACE WALL PANEL SHALL BE LOCATED NOT MORE THAN 10.0-FT <br />FROM THE END OF A BRACED WALL LINE AS DEMONSTRATED IN FIGURE <br />R602.10.2.2 OF THE LARC. <br />4. HOLD-DOWN DEVICE SHALL BE APPROVED BY CURRENT LOS ANGELES CITY <br />RESEARCH REPORT. <br />BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY <br />Roof/Ceiling Dead Load = 15-psf <br />Wall Height = 10-ft <br />Floor Dead Load = 10-psf <br />Braced Wall Line Spacing = 25-ft <br />Seismic Design <br />Category (SDC)Story Location Braced Wall Line <br />Length <br />10 <br />SDC D2 <br />20 <br />30 <br />40 <br />50 <br />Minimum Total Length of Braced Wall Panels Required <br />Along each Braced Wall Line <br />(ft) <br />Methods GB a, d and PCP b, d <br />8 <br />16 <br />24 <br />32 <br />40 <br />Method WSP c <br />4 <br />5 <br />7.5 <br />10 <br />12.5 <br />(a). Method GB (Gypsum Board) = ½-in. minimum thickness gypsum board with 1-1/2-in. galvanized roofing nail, or 1-1/4-in. screws, Type W or S. for exterior sheathing, or 5d <br />cooler nail, 0.086-in. diameter, 1-5/8-in. long, 15/64-in head for interior gypsum board. Maximum fastener spacing shall be 7-in. o.c. at panel edges, including top and bottom <br />plates, and along intermediate supports. When method GB panels are applied to only one face of a braced wall panel, the minimum total length in the table shall be doubled. <br />(b). Method PCP (Portland Cement Plaster) = 7/8-in. minimum thickness Portland cement plaster with 1-1/2-in., 11-gage, 7/16-in. head nails at 6-in. spacing (16-in stud spacing <br />required). ½-in. minimum gypsum wallboard shall be installed on the side of the wall opposite the bracing material, except when the minimum total length of braced wall panel <br />in the Table is multiplied by a factor of 1.5. <br />(c). Method WSP (Wood Structural Panel) = 15/32-in. minimum thickness wood structural panel with 8d common (2-1/2-in x 0.131-in.) nails at 6-in. spacing along panel edges, <br />12-in. spacing at intermediate supports, and 3/8-in. distance to panel edge. ½-in. minimum thickness gypsum wall board shall be installed on the side of the wall opposite the <br />bracing material, except when the minimum total length of braced wall panel in the Table is multiplied by a factor of 1.5. <br />(d). Method GB and PCP braced wall panel height to width ratio (h/w) shall not exceed 1:1. <br />(e). Multiply required braced wall panel lengths specified in the table by 1.2 when combined Roof Ceiling Dead load is between 15 psf and 25 psf. <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, <br />will provide reasonable accommodation to ensure equal access to its programs, services and activities. <br />Page 7 of 9 <br />BR <br />A <br />C <br />E <br />D <br /> <br />W <br />A <br />L <br />L <br /> <br />L <br />I <br />N <br />E <br /> <br />L <br />E <br />N <br />G <br />T <br />H <br />25 <br />' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />( <br />T <br />Y <br />P <br />) <br />H <br />( <br />H <br />E <br />I <br />G <br />H <br />T <br /> <br />O <br />F <br /> <br />P <br />A <br />N <br />E <br />L <br />) <br /> <br />1 <br />0 <br />' <br /> <br />M <br />A <br />X <br />. <br />P/BC 2023-004 <br />________________________________________________________________ <br />SEISMIC STRAPS: TWO MIN. <br />REFER TO IB P/PC 2017-003 <br />FOR REQUIREMENTS <br />T&P VALVE PIPED TO EXTERIOR <br />3/4" MIN. PIPE. NO THREADS <br />ALLOWED IN BOTTOM PIPING <br />4" <br />LISTED CAP <br />24" MIN. <br />ROOF SLOPE: <br />FLAT TO 6:12 <br />PER. MANUF. <br />RECOMMENDATION <br />SEE LA MECHANICAL CODE SEC. 802.6 <br />FOR ROOF SLOPE STEEPER THAN 6:12 <br />GARAGE FLOOR <br />NOTE: NO GAS-FIRED WATER HEATER ALLOWED IN BEDROOMS, BATHROOMS, <br />CLOTHES CLOSETS, OR ANY SPACE OPENING INTO A BEDROOM OR BATHROOM. <br />WATER HEATERS <br />20" CLEAR <br />WATER HEATER VENT AND ACCESS REQUIREMENTS <br />THE FOLLOWING WINDOW SIZES WILL BE THE MINIMUM ALLOWED FOR 5.0 SF. <br />30" CLEAR <br />OPENABLE <br />AREA <br />SINGLE CASEMENT: 2-4 X 4-0, <br />2-6 X 3-6 <br />OPENABLE <br />AREA <br />DOUBLE CASEMENT: 4-8 X 4-0 <br />CASEMENT/ FIXED COMBO: 7-0 X 4-0 <br />OTHER WINDOW TYPES: <br />AWNING & BAY W/ FIXED CENTER: <br />NONE W/O MANUF. DATA <br />SINGLE/ DOUBLE HUNG: <br />3-0 X 5-0, 3-0 X 5-6 ,3-4 X 5-0, <br />3-8 X 5-0, 4-0 X 5-0 <br />SINGLE/ FIXED COMBO: NONE W/O <br />MANUF. DATA <br />MIN. SIZE WINDOW <br />FOR 20" CLEAR WIDTH AND <br />5.0 S.F. OPENABLE AREA <br />SLIDER: <br />4-0 X 4-0 <br />5-0 X 3-6 <br />6-0 X 3-0 <br />SLIDER/ FIXED COMBO: <br />8-0 X 4-0 <br />10-0 X 4-0 <br />12-0 X 3-0 <br />MIN. SIZE WINDOW <br />FOR 24" CLEAR HEIGHT AND 5.0 <br />S.F. OPENABLE AREA <br />FLOOR LEVEL <br />1. 20" MIN. CLEAR WIDTH <br />2. 24" MIN. CLEAR HEIGHT <br />3. 5.0 SF MIN. OPENABLE AREA AT GRADE-FLOOR ONLY, 5.7 SF MIN. ELSEWHERE. <br />EMERGENCY ESCAPE/ RESCUE OPENING (R310) <br />1/2" MIN. CLEAR ON TOPS, <br />SIDES AND ENDS <br />NOTE: SIZES ARE TAKEN FROM DATA SUPPLIED BY <br />WINDOW MANUFACTURERS. HOWEVER, THESE ARE <br />GENERAL DIMENSIONS AND MUST BE VERIFIED WITH <br />ACTUAL WINDOWS INSTALLED TO MEET MINIMUM <br />EGRESS REQUIREMENTS. <br />CONC. FOUND. WALL <br />FLOOR GIRDER <br />1:1 <br />P.T. SILL <br />3" MIN. BEARING1'-6" MIN. <br />TRENCHES AT FOOTINGS GIRDER (R317.1 / R502.6) <br />As a covered entity under Title II of the Americans with Disabilities Act, the City of Los Angeles does not discriminate on the basis of disability and, upon request, <br />will provide reasonable accommodation to ensure equal access to its programs, services and activities. <br />Page 8 of 9 <br />36 <br />" <br /> <br />C <br />L <br />E <br />A <br />R <br />RA <br />I <br />S <br />E <br /> <br />1 <br />8 <br />" <br />IN <br /> <br />G <br />A <br />R <br />A <br />G <br />E <br />44 <br />" <br /> <br />M <br />A <br />X <br />24 <br />" <br /> <br />C <br />L <br />E <br />A <br />R <br />6" <br /> <br />M <br />I <br />N <br />. <br />24 <br />" <br /> <br />M <br />A <br />X <br />EX <br />T <br />E <br />R <br />I <br />O <br />R <br /> <br />W <br />A <br />L <br />L <br />BO <br />T <br />T <br />O <br />M <br /> <br />1 <br />/ <br />3 <br />TO <br />P <br /> <br />1 <br />/ <br />3 <br />44 <br />" <br /> <br />M <br />A <br />X <br />PE <br />R <br /> <br />M <br />A <br />N <br />U <br />F <br />. <br />RE <br />C <br />O <br />M <br />E <br />N <br />D <br />A <br />T <br />I <br />O <br />N <br />12 <br />" <br /> <br />M <br />I <br />N <br />. <br />FO <br />R <br /> <br />R <br />O <br />O <br />F <br /> <br />S <br />L <br />O <br />P <br />E <br />: <br />FL <br />A <br />T <br /> <br />T <br />O <br /> <br />6 <br />: <br />1 <br />2 <br />627 S Shelton St & <br />#212/4/2024