Laserfiche WebLink
V E C O <br />d e s i g n - s t u d i o <br />SHEET: <br />JOB No: <br />DATE: <br />DRAWN BY: <br />PLAN: <br />PHONE: <br />JOB SITE: <br />PROJECT NAME: <br />REVISION:BY: <br />VASQUEZ <br />RESIDENCE <br />23-017 <br />06-21-2024 <br />S.V <br />714-713-3124 <br />627, 627 UNIT 2 S. SHELTON. ST. <br />SANTA ANA, CA 92703 <br />d e s i g n e r <br />O s c a r V e g a <br />C e 1 4 - 4 -1 2 4 <br />O i e 3 1 - 2 3 -3 5 <br />i n o e o d e s i g n s .o <br />5 3 4 C O A V E . <br />A A E C A 2 5 <br />APPROVED BY :O.V. <br />GENERAL NOTES <br />G-3 <br />SAFETY GLAZING (I.E., TEMPERED) WINDOWS IN BATHROOMS [CRC 308.4.5] <br />·WINDOWS IN ANY PORTION OF A WALL ENCLOSING TUBS AND/OR SHOWERS WHERE THE BOTTOM EDGE OF THE <br />GLAZING IS LESS THAN 60” ABOVE THE STANDING SURFACE. <br />·WINDOWS WITHIN 60” MEASURED HORIZONTALLY FROM WATER’S EDGE OF A BATHTUB OR WHIRLPOOL TUB OR FROM <br />EDGE OF A SHOWER AND WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60” ABOVE THE WALKING SURFACE. <br />WATER CONSERVING PLUMBING FIXTURES [CALIFORNIA CIVIL CODE 1101.4(A)] <br />THE CALIFORNIA CIVIL CODE REQUIRES THAT ALL EXISTING NON-COMPLIANT PLUMBING FIXTURES (BASED ON WATER <br />EFFICIENCY) THROUGHOUT THE HOUSE BE UPGRADED WHENEVER A BUILDING PERMIT IS ISSUED FOR REMODELING <br />IMPROVEMENTS EVEN IF THE FIXTURES ARE NOT WITHIN THE SCOPE OF WORK. RESIDENTIAL BUILDING CONSTRUCTED AFTER <br />JANUARY 1, 1994 ARE EXEMPT FROM THIS REQUIREMENT. THE FOLLOWING TABLE SHOWS THE FIXTURES THAT ARE <br />CONSIDERED TO BE NON-COMPLAINT AND THE TYPE OF WATER-CONSERVING PLUMBING FIXTURE THAT SHOULD BE <br />INSTALLED: <br />TYPE OF FIXTURE <br />WATER CLOSET (TOILET) <br />URINAL <br />SHOWER HEAD <br />FAUCET-BATHROOM <br />FAUCET-KITCHEN <br />NON-COMPLIANT <br />PLUMBING FIXTURE <br />MORE THAN <br />1.6 GAL./ FLUSH <br />MORE THAN <br />1.0 GAL./ FLUSH <br />MORE THAN <br />2.5 GAL./ MINUTE <br />MORE THAN <br />2.2 GAL./ MINUTE <br />MORE THAN <br />2.2 GAL./ MINUTE <br />REQUIRED WATER-CONSERVING <br />PLUMBING FIXTURE (MAX. RATE) <br />CALGREEN 4.303 <br />1.28 GALLONS / FLUSH <br />0.125 GAL. / FLUSH FOR WALL <br />MOUNT; 0.50 FOR OTHERS <br />2.0 GALLONS / MINUTE AT 80 PSI <br />1.2 GALLONS / MINUTE AT 80 PSI <br />1.8 GALLONS / MINUTE AT 80 PSI <br />PLUMBING <br />·PROVIDE TEMPERED GLASS AT TUB/SHOWER DOORS AND AT WINDOWS LESS THAN 60” FROM TUB/SHOWER DRAIN. <br />·SHOWER AND TUB/SHOWER CONTROL VALVES SHALL BE PRESSURE BALANCING SET AT A MAXIMUM 120 DEGREES F. <br />THE WATER-FILLER VALVE IN BATHTUB/WHIRLPOOLS SHALL HAVE A TEMPERATURE LIMITING DEVICE SET A MAXIMUM <br />OF 120 DEGREES F REGULATED BY EITHER A LIMITING DEVICE CONFORMING TO EITHER ASSE 1070/A112.1070/CSA <br />B125.70 OR CSA B125.3 OR A WATER HEATER CONFORMING TO ASSE 1084. [CPC 408.3, 409.4] <br />·FIXTURES SHALL MEET THE FOLLOWING MAXIMUM FLOW RATES: [CPC 407.0, 408.2 & 411.0] <br />WATER CLOSETS = 1.28 GALLONS/FLUSH ― SHOWER HEADS = 1.8 GPM ― SINK FAUCETS = 1.2 GPM <br />·MINIMUM SHOWER SIZE IS 1024 SQUARE INCHES (30” CIRCLE). [CPC 408.6] SHOWER WITHOUT THRESHOLD SHALL BE <br />CONSIDERED A WET LOCATION AND SHALL COMPLY WITH CALIFORNIA BUILDING, RESIDENTIAL, AND ELECTRICAL CODES. <br />•SITE BUILT SHOWER STALLS SHALL COMPLY WITH CPC 408.7. <br />•STALL SHOWER DOOR TO PROVIDE A MIN. OF 22” WIDE UNOBSTRUCTED OPENING. [CPC408.5]. <br />•TOILET AND/OR BIDET REQUIRE A TOTAL MINIMUM 30” CLEAR SPACE, 15” FROM THE CENTER OF THE FIXTURE TO THE <br />WALL, AND A MINIMUM OF 24” CLEAR SPACE IN FRONT OF THE FIXTURE. [CPC 402.5] <br />•WHEN ADDITIONAL WATER CLOSETS (TOILETS) ARE INSTALLED, A MAXIMUM OF 5 WATER CLOSETS ARE ALLOWED ON A <br />3” WASTE LINE. [TABLE 703.2, NOTE 4] <br />•THE HOT WATER VALVE SHALL BE INSTALLED ON THE LEFT SIDE. [CPC 417.5] <br />•A MINIMUM 12” X 12” ACCESS PANEL IS REQUIRED WHEN A SLIP JOINT P-TRAP WASTE & OVERFLOW IS PROVIDED. <br />[402.10] <br />•WHERE PLUMBING FEATURES (WATER CLOSETS, TUBS, ETC.) COMES INTO CONTACT WITH THE WALL OR FLOOR, THE <br />JOINT SHALL BE CAULKED AND SEALED TO BE WATERTIGHT. [CPC 402.2] <br />ELECTRICAL <br />·PROVIDE A 20 AMP GFCI PROTECTED ELECTRICAL OUTLET WITHIN 36” OF THE OUTSIDE EDGE OF EACH BATHROOM SINK <br />BASIN. OUTLET SHALL BE LOCATED ON A WALL OR ARTITION THAT IS ADJACENT TO THE BASIN OR INSTALLED ON THE <br />SIDE OR FACE OF THE ASIN CABINET NOT MORE THAN 12” BELOW THE COUNTERTOP. [CEC 210.52(D)] <br />·RECEPTACLES SHALL BE LISTED AS TAMPER-RESISTANT. <br />·A MINIMUM OF ONE (1) 20-AMP CIRCUIT IS REQUIRED FOR BATHROOMS. SUCH CIRCUITS SHALL HAVE NO OTHER <br />OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM. [CEC 210.52(D)] & [CEC 210.11(C)(3)] <br />·NO PENDANT LIGHT FIXTURES IN ZONE, 3 FT. AWAY AND 8 FT. ABOVE THE BATHTUB OR SHOWER. [CEC 410.10(D)] <br />·LUMINARIES LOCATED WITHIN THE ACTUAL OUTSIDE DIMENSIONS OF THE TUB, SHOWER, AND CEILING SUSPENDED <br />PADDLE FANS, UP TO 8 FEET VERTICALLY FROM THE TOP OF THE BATHTUB RIM OR SHOWER THRESHOLD, SHALL BE <br />MARKED AS SUITABLE FOR DAMP LOCATIONS, PROVIDED WITH A SOLID LENS AND BE GFCI PROTECTED. [CEC 410.10(D)] <br />·BATHROOM LIGHTING SHALL BE HIGH EFFICACY LUMINARIES IN ACCORDANCE WITH TABLE 150.0-A OF 2022 <br />CALIFORNIA ENERGY CODE AND HAVE AT LEAST ONE LUMINAIRE IN EACH SPACE CONTROLLED BY A VACANCY SENSOR <br />150.0(K)2C. <br />·RECESSED LUMINARIES INSTALLED IN AN INSULATED CEILING SHALL BE IC RATED (ZERO CLEARANCE) AND AT RATED <br />(AIR TIGHT) AND SHALL BE SEALED AND/OR GASKET BETWEEN CEILING AND HOUSING. FOR OCCUPANCIES WITH A <br />HORIZONTAL (FLOOR/CEILINg ASSEMBLY) RATED SEPARATION, THE RECESSED FIXTURES SHALL BE PROTECTED TO THE <br />RATING OF THE SEPARATION (1 HOUR) OR BE LISTED FOR THE REQUIRED PROTECTION. THIS GENERALLY APPLIED TO <br />RESIDENTIAL CONDOMINIUM CONSTRUCTION WHERE UNITS ARE ABOVE OR BELOW OTHER UNITS. <br />·HYDRO-MASSAGE TUBS (I.E. JACUZZI TUBS) SHALL HAVE ACCESS TO THE MOTOR, BE SUPPLIED BY A GFCI PROTECTED <br />DEDICATED CIRCUIT, AND LISTED BY A RECOGNIZED TESTING AGENCY. ALL PIPING, FITTING, METAL CABLES OR OTHER <br />METAL SURFACES, WITHIN 5 FEET OF THE INSIDE WALL OF THE HYDRO-MASSAGE TUB SHALL BE PROPERLY BONDED. <br />HYDRO-MASSAGE TUBS SHALL BE BONDED WITH A MINIMUM #8 AWG BARE COPPER WIRE AND THE BONDING SHALL BE <br />ACCESSIBLE. [CEC 680.60] <br />ALL RECESSED DOWNLIGHT LUMINARIES SHALL BE IN ACCORDANCE WITH REFERENCE JOINT APPENDIX JA8 AND BE <br />MARKED AS MEETING JA8. <br />KITCHEN NOTESBATHROOM NOTES <br />WHIRLPOOL/SPA TUBS <br />•WHIRLPOOL (SPA) BATHTUBS SHALL HAVE A READILY ACCESSIBLE ACCESS PANEL. [CPC 409.6] <br />•THE CIRCULATION PUMP SHALL BE LOCATED ABOVE THE CROWN WEIR OF THE TRAP. [CPC 409.6] <br />•THE PUMP AND THE CIRCULATION PIPING SHALL BE SELF-DRAINING TO MINIMIZE WATER RETENTION. [CPC 409.6] <br />•SUCTION FITTINGS ON WHIRLPOOL BATHTUBS SHALL COMPLY WITH THE LISTED STANDARDS. [CPC 409.6] <br />•FLEXIBLE PVC HOSES AND TUBING FOR WHIRLPOOL BATHTUBS MUST COMPLY WITH IAPMOZ1033. [409.6.1] <br />BIDETS <br />•THE WATER SUPPLY SHALL BE PROTECTED WITH AIR GAP OR VACUUM BREAKER. [CPC 410.2] <br />•THE MAXIMUM HOT WATER TEMPERATURE DISCHARGING FROM A BIDET IS LIMITED TO 110 DEGREES BY A DEVICE THAT <br />CONFORMS TO ASSE 1070/ASME A112.1070/CSA B125.70 OR CSA B125.3 OR A WATER HEATER CONFORMING TO <br />ASSE 1084 [CPC 410.3]. <br />PLUMBING FIXTURE REPLACEMENT: <br />EFFECTIVE JANUARY 1, 2014, SENATE BILL (SB) 407 AND CALIFORNIA CIVIL CODE SECTION 1101.1-1101.8 REQUIRES ALL <br />NONCOMPLIANT PLUMBING FIXTURES TO BE REPLACED WITH WATER-CONSERVING PLUMBING FIXTURES WHEN BUILDING IS <br />UNDERGOING ALTERATIONS OR IMPROVEMENTS IF THE RESIDENTIAL PROPERTY WAS BUILT AND AVAILABLE FOR USE ON OR <br />BEFORE JANUARY 1, 1994. PLEASE REFER TO “PLUMBING FIXTURE REPLACEMENT (SB407) REQUIREMENTS AND POLICY” TO <br />DETERMINE IF THE PROJECT REQUIRES COMPLIANCE. <br />SMOKE ALARMS & CARBON MONOXIDE ALARMS: <br />AGING-IN PLACE REQUIREMENTS <br />a.DOORBELL BUTTONS - DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES <br />ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE <br />DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48 INCHES <br />MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO <br />BE PROVIDED AT A HEIGHT NOT EXCEEDING 48 INCHES ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM <br />THE TOP OF THE DOORBELL BUTTON OR CONTROL. (CRC R327.1.4) <br />b.ELEMENTS - AT LEAST ONE BATHROOM ON THE ENTRY LEVEL (SEE DEFINITION) SHALL BE PROVIDED WITH <br />REINFORCEMENT INSTALLED IN ACCORDANCE WITH CRC R327.1. WHERE THERE IS NO BATHROOM ON THE ENTRY <br />LEVEL, AT LEAST ONE BATHROOM ON THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL COMPLY WITH CRC <br />R327.1. <br />a.REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING <br />AGENCY. <br />b.REINFORCEMENT SHALL NOT BE LESS THAN 2X8 NOMINAL LUMBER (1-1/2 INCH BY 7-1/4 INCH ACTUAL <br />DIMENSION) OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. <br />REINFORCEMENT SHALL BE LOCATED BETWEEN 32 INCHES AND 39-1/4 INCHES ABOVE THE FINISHED FLOOR FLUSH <br />WITH THE WALL FRAMING. <br />c.WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL <br />AND THE BACK WALL. <br />d.SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. <br />e.BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE <br />BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE <br />PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES ABOVE THE BATHTUB RIM. <br />EXCEPTIONS: <br />i.WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB <br />BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED, FOLDAWAY, OR SIMILAR <br />ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE ENFORCING AGENCY. <br />ii.REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR PRE-FABRICATED SHOWER ENCLOSURES AND <br />BATHTUB WALL PANELS WITH INTEGRAL FACTORY- INSTALLED GRAB BARS OR WHEN FACTORY-INSTALLED <br />REINFORCEMENT FOR GRAB BARS IS PROVIDED. <br />iii.SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/OR GRAB BARS SHALL BE <br />PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS OR AN ALTERNATE <br />METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />iv.BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS DO NOT PERMIT THE INSTALLATION OF <br />REINFORCEMENT SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED <br />GRAB BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />v.REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS AND WATER CLOSETS INSTALLED ON <br />CONCRETE SLAB FLOORS. <br />c.DOCUMENTATION FOR GRAB BAR REINFORCEMENT - INFORMATION AND/OR DRAWINGS IDENTIFYING THE <br />LOCATION OF GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION AND MAINTENANCE MANUAL IN <br />ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 4, DIVISION 4.4. (CRC <br />R327.1.1.1) <br />d.ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS - ELECTRICAL RECEPTACLE OUTLETS, <br />SWITCHES, AND CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDED <br />TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE <br />OUTLET BOX AND NOT LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE <br />FINISH FLOOR. PLEASE INDICATE ON THE PLANS. (CRC R327.1.2) <br />EXCEPTIONS: <br />i.DEDICATED RECEPTACLE OUTLETS; FLOOR RECEPTACLE OUTLETS; CONTROLS MOUNTED ON CEILING FANS AND <br />CEILING LIGHTS; AND CONTROLS LOCATED ON APPLIANCES. <br />ii.RECEPTACLE OUTLETS REQUIRED BY THE CALIFORNIA ELECTRICAL CODE ON A WALL SPACE WHERE THE DISTANCE <br />BETWEEN THE FINISHED FLOOR AND A BUILT-IN FEATURE ABOVE THE FINISH FLOOR, SUCH AS A WINDOW, IS LESS <br />THAN 15 INCHES. <br />N.T.S. <br />1'-1/2" <br />GRAB BAR DETAIL (SIDE VIEW) <br />GYPSUM BOARD <br />2x8 SOLID WOOD <br />BLOCKING <br />2x WOOD STUD <br />ESCUTCHEON PLATE <br />21 2" LONG S.S. <br />FASTENER <br />(SCREWS) <br />2x WOOD STUD <br />2x8 SOLID WOOD BLOCKING <br />21 2" LONG S.S. <br />FASTENER (SCREWS) <br />ESCUTCHEON PLATE <br />1-1/4 " TO 2" <br />NOMINAL <br />DIAMETER <br />21 <br />2" <br />- <br /> <br />3 <br />" <br />GRAB BAR DETAIL (FRONT VIEW) <br />GYPSUM BOARD <br />NOMINAL <br />DIAMETER <br />1-1/4 " TO 2" <br />GRAB BAR REINFORCEMENT <br />ELEVATION VIEW <br />N.T.S. <br />ELECTRIC READY REQUIREMENTS <br />A. WATER HEATING SYSTEM - REQUIREMENT FOR ACCOMMODATION FOR FUTURE HEAT PUMP WATER HEATER - <br />SYSTEMS USING GAS OR PROPANE WATER HEATERS TO SERVE INDIVIDUAL DWELLING UNITS SHALL DESIGNATE A <br />SPACE AT LEAST 2.5 FEET BY 2.5 FEET WIDE AND 7 FEET TALL SUITABLE FOR THE FUTURE INSTALLATION OF A HEAT <br />PUMP WATER HEATER (HPWH) BY MEETING EITHER A OR B BELOW. ALL ELECTRICAL COMPONENTS SHALL BE <br />INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE: (CENC 150.0(N)(1)) <br />I. IF THE DESIGNATED SPACE IS WITHIN 3 FEET FROM THE WATER HEATER, THEN THIS SPACE SHALL INCLUDE THE <br />FOLLOWING: <br />1.A DEDICATED 125 VOLT, 20 AMP ELECTRICAL RECEPTACLE THAT IS CONNECTED TO THE ELECTRIC PANEL WITH <br />A 120/240 VOLT 3 CONDUCTOR, 10 AWG COPPER BRANCH CIRCUIT, WITHIN 3 FEET FROM THE WATER HEATER <br />AND ACCESSIBLE TO THE WATER HEATER WITH NO OBSTRUCTIONS; AND <br />2.BOTH ENDS OF THE UNUSED CONDUCTOR SHALL BE LABELED WITH THE WORD "SPARE" AND BE ELECTRICALLY <br />ISOLATED; AND <br />3.A RESERVED SINGLE POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL PANEL ADJACENT TO THE CIRCUIT <br />BREAKER FOR THE BRANCH CIRCUIT IN A ABOVE AND LABELED WITH THE WORDS "FUTURE 240V USE"; AND <br />4.A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE BASE OF THE INSTALLED WATER <br />HEATER, AND ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE. <br />II. IF THE DESIGNATED SPACE IS MORE THAN 3 FEET FROM THE WATER HEATER, THEN THIS SPACE SHALL INCLUDE <br />THE FOLLOWING: <br />1.A DEDICATED 240 VOLT BRANCH CIRCUIT SHALL BE INSTALLED WITHIN 3 FEET FROM THE DESIGNATED SPACE. <br />THE BRANCH CIRCUIT SHALL BE RATED AT 30 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS <br />"240V READY"; AND <br />2.THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF <br />A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE HPWH INSTALLATION. THE RESERVED SPACE SHALL BE <br />PERMANENTLY MARKED AS "FOR FUTURE 240V USE"; AND <br />3.EITHER A DEDICATED COLD WATER SUPPLY, OR THE COLD WATER SUPPLY SHALL PASS THROUGH THE <br />DESIGNATED HPWH LOCATION JUST BEFORE REACHING THE GAS OR PROPANE WATER HEATER; AND <br />4.THE HOT WATER SUPPLY PIPE COMING OUT OF THE GAS OR PROPANE WATER HEATER SHALL BE ROUTED <br />FIRST THROUGH THE DESIGNATED HPWH LOCATION BEFORE SERVING ANY FIXTURES; AND <br />5.THE HOT AND COLD WATER PIPING AT THE DESIGNATED HPWH LOCATION SHALL BE EXPOSED AND READILY <br />ACCESSIBLE FOR FUTURE INSTALLATION OF AN HPWH; AND <br />6.A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE BASE OF THE INSTALLED WATER <br />HEATER, AND ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE. <br />B. ENERGY STORAGE SYSTEMS (ESS) READY. ALL SINGLE-FAMILY RESIDENCES THAT INCLUDE ONE OR TWO DWELLING <br />UNITS SHALL MEET THE FOLLOWING. ALL ELECTRICAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH <br />THE CALIFORNIA ELECTRICAL CODE: (CENC 150.0(S)) <br />I. AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED: <br />1.ESS READY INTERCONNECTION EQUIPMENT WITH A MINIMUM BACKED-UP CAPACITY OF 60 AMPS AND A MINIMUM <br />OF FOUR ESS-SUPPLIED BRANCH CIRCUITS, OR <br />2.A DEDICATED RACEWAY FROM THE MAIN SERVICE TO A PANELBOARD (SUBPANEL) THAT SUPPLIES THE BRANCH <br />CIRCUITS IN SECTION 150.0(S)(2). ALL BRANCH CIRCUITS ARE PERMITTED TO BE SUPPLIED BY THE MAIN SERVICE <br />PANEL PRIOR TO THE INSTALLATION OF AN ESS. THE TRADE SIZE OF THE RACEWAY SHALL BE NOT LESS THAN 1 <br />INCH. THE PANELBOARD THAT SUPPLIES THE BRANCH CIRCUITS (SUBPANEL) MUST BE LABELED "SUBPANEL <br />SHALL INCLUDE ALL BACKED-UP LOAD CIRCUITS." <br />II A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE IDENTIFIED AND HAVE THEIR SOURCE OF SUPPLY COLLOCATED <br />AT A SINGLE PANELBOARD SUITABLE TO BE SUPPLIED BY THE ESS. AT LEAST ONE CIRCUIT SHALL SUPPLY THE <br />REFRIGERATOR, ONE LIGHTING CIRCUIT SHALL BE LOCATED NEAR THE PRIMARY EGRESS AND AT <br /> LEAST ONE CIRCUIT SHALL SUPPLY A SLEEPING ROOM RECEPTACLE OUTLET. <br />III THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING OF 225 AMPS. <br />IV SUFFICIENT SPACE SHALL BE RESERVED TO ALLOW FUTURE INSTALLATION OF A SYSTEM ISOLATION <br />EQUIPMENT/TRANSFER SWITCH WITHIN 3 FEET OF THE MAIN PANELBOARD. RACEWAYS SHALL BE INSTALLED <br />BETWEEN THE PANELBOARD AND THE SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH LOCATION TO ALLOW THE <br />CONNECTION OF BACKUP POWER SOURCE. <br />C. ELECTRIC COOKTOP READY. SYSTEMS USING GAS OR PROPANE COOKTOP TO SERVE INDIVIDUAL DWELLING UNITS <br />SHALL INCLUDE THE FOLLOWING: (CENC 150.0(U)) <br />i.A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FEET FROM THE COOKTOP AND <br />ACCESSIBLE TO THE COOKTOP WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT <br />50 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS "240V READY." ALL ELECTRICAL COMPONENTS <br />SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE. <br />ii.THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A <br />DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE ELECTRIC COOKTOP INSTALLATION. THE RESERVED SPACE SHALL <br />BE PERMANENTLY MARKED AS "FOR FUTURE 240V USE." <br />D.ELECTRIC CLOTHES DRYER READY. CLOTHES DRYER LOCATIONS WITH GAS OR PROPANE PLUMBING TO SERVE <br />INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING: (CENC 150.0(V)) <br />i.A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FEET FROM THE CLOTHES DRYER <br />LOCATION AND ACCESSIBLE TO THE CLOTHES DRYER LOCATION WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT <br />CONDUCTORS SHALL BE RATED AT 30 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS "240V READY." <br />ALL ELECTRICAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE. <br />ii.THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE <br />INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE ELECTRIC CLOTHES DRYER <br />INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS "FOR FUTURE 240V USE. <br />MECHANICAL <br />PLUMBING <br />SMOKE / CARBON MONOXIDE ALARMS <br />·KITCHEN RENOVATIONS (PROJECTS OVER $1,000) WILL REQUIRE THE SMOKE AND CARBON MONOXIDE ALARMS FOR <br />THE DWELLING TO MEET THE CURRENT CODE (CRC SECTIONS R314 AND R315). <br />·SMOKE ALARMS ARE REQUIRED IN ALL SLEEPING ROOMS, OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY <br />OF THE BEDROOMS, ON EACH FLOOR LEVEL INCLUDING BASEMENTS AND HABITABLE ATTICS, BUT NO INCLUDING CRAWL <br />SPACES AND UNINHABITABLE ATTICS. <br />·CARBON MONOXIDE ALARMS ARE REQUIRED IN DWELLING UNITS AND SLEEPING UNITS WHEN FUEL-BURNING <br />APPLIANCES ARE INSTALLED AND/OR DWELLING UNITS HAVE ATTACHED GARAGES. EITHER CONDITION REQUIRES THE <br />ALARMS. <br />·WHEN MORE THAN ONE ALARM OF EITHER TYPE IS REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT, <br />THE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT ACTIVATION OF ONE ALARM WILL ACTIVATE <br />ALL THE OTHER ALARMS. <br />·IN EXISTING CONDITIONS, ALARMS MAY BE BATTERY OPERATED WHEN THE REPAIRS OR ALTERATIONS DO NOT RESULT <br />IN THE REMOVAL OF THE WALL AND CEILING FINISHES OR THERE IS NO ACCESS BY MEANS OF AN ATTIC, BASEMENT OR <br />CRAWLSPACE. <br />·MULTIPURPOSE ALARMS THAT COMBINE BOTH A SMOKE ALARM AND CARBON MONOXIDE ALARM SHALL COMPLY WITH <br />ALL APPLICABLE STANDARDS OF BOTH CRC SECTIONS R314 AND R315 AND BE LISTED BY THE OFFICE OF THE STATE <br />FIRE MARSHAL. <br />ALTERATION AND/OR RENOVATION OF THE KITCHEN TRIGGER THE UPGRADE TO CURRENT MECHANICAL CODES COMPLIANCE <br />CONSISTING OF THE FOLLOWING: <br />·A DUCTED RESIDENTIAL EXHAUST HOOD IS REQUIRED. A METAL, SMOOTH INTERIOR SURFACE DUCT REQUIRED ON VENT <br />HOOD OR DOWN DRAFT EXHAUST VENT. ALUMINUM OR STEEL FLEX DUCT NOT APPROVED. PROVIDE A BACK DRAFT <br />DAMPER (CMC 504.3). <br />·DUCTS FOR DOMESTIC DOWNDRAFT GRILL/RANGE VENTILATION INSTALLED UNDER A CONCRETE SLAB MAY BE OF <br />APPROVED SCHEDULE 40 PVC PROVIDED: O THE UNDER FLOOR TRENCH IN WHICH THE DUCT IS INSTALLED SHALL BE <br />COMPLETELY BACKFILLED WITH SAND OR GRAVEL. O NOT MORE THAN 1“ OF 6” DIAMETER THE PVC COUPLING MAY <br />PROTRUDE ABOVE THE FLOOR SURFACE. O PVC PIPE JOINTS SHALL BE SOLVENT CEMENTED TO PROVIDE AN AIR AND <br />GREASE TIGHT DUCT. O THE DUCT SHALL TERMINATE ABOVE GRADE OUTSIDE THE BUILDING AND SHALL BE EQUIPPED <br />WITH A BACK DRAFT DAMPER. <br />·MINIMUM 30” VERTICAL CLEARANCE TO COMBUSTIBLES FROM COOK TOP SURFACE IS REQUIRED (CMC 920.3.2). <br />·KITCHEN LOCAL EXHAUST VENTILATION REQUIRES A MINIMUM RATE OF 100 CFM MEETING THE REQUIREMENTS OF <br />ASHRA 62.2. THIS INCLUDES A MAXIMUM SOUND RATING OF 3 SONE @ 100 CFM (TABLE 403.7). RECIRCULATION TYPES <br />ARE NOT ALLOWED BY CODE. <br />·THE SIZE AND LENGTH OF THE DUCTING MUST BE DETAILED ON THE PLAN. <br />ALTERATIONS THAT DO NOT REPLACE OR RELOCATE THE EXISTING FAN OR WHEN THE CEILING FINISHES ARE NOT REMOVED <br />AND/OR THERE IS NO ACCESS AVAILABLE FOR THE INSTALLATION OF AN EXHAUST FAN, MAY CONTINUE TO USE THE EXISTING <br />EXHAUST FANS PROVIDED THEY VENT TO THE OUTSIDE AIR. KITCHENS THAT DO NOT INCLUDE AN EXISTING FAN MUST INSTALL <br />A COMPLIANT FAN AT THE TIME OF THE RENOVATION. A RECIRCULATING TYPE HOOD IS NOT AN APPROVED INSTALLATION. <br />IN SOME CASES, THE DESIGN OF THE STRUCTURE WILL NOT ALLOW THE INSTALLATION OF A DUCT, TYPICALLY IN A <br />MULTI-FAMILY UNIT (CONDO). IN THESE CASES AN EXEMPTION MAY BE APPLIED FOR USING THE RESIDENTIAL REQUEST FOR <br />MODIFICATION APPLICATION AND APPROVAL IS BASED ON A REVIEW BY THE BUILDING OFFICIAL. <br />ALTERATION AND/OR RENOVATION OF THE KITCHEN ARE REQUIRED TO MEET THE CURRENT PLUMBING CODES. ALTHOUGH <br />EACH PROJECT IS UNIQUE, THE BASIC REQUIREMENTS CONSIST OF THE FOLLOWING: <br />·A GAS TEST IS REQUIRED ON PIPING MODIFICATIONS (10 PSI FOR 15 MINUTES). A MAXIMUM 15 PSI GAUGE IS REQUIRED <br />FOR THE GAS TEST. <br />·GAS LINES THAT RUN UNDER A SLAB SHALL RUN THROUGH AN APPROVED, VENTED, GAS TIGHT CONDUIT (CPC 1210.1.6). <br />·AN ACCESSIBLE SHUTOFF VALVE, FLEX GAS APPLIANCE CONNECTOR FOLLOWED BY A “TEE” SEDIMENT TAP IS THE <br />ORDER OF INSTALLATION PRIOR TO EACH APPLIANCE IN ADDITION TO ANY VALVE ON THE APPLIANCE (CPC 1212.6 AND <br />1212.9). <br />·PROVIDE MAXIMUM 6’ LONG LISTED GAS FLEXIBLE CONNECTOR AND SHUT OFF TO A FREE STANDING RANGE <br />(CPC1212.6). <br />·A LISTED AIR GAP IS REQUIRED FOR THE DISHWASHER DRAIN (CPC 807.3); A LOOP PROVIDED INSIDE THE CABINET IS <br />NOT APPROVED WITHIN THE CITY OF DANA POINT. <br />·THE MAXIMUM FLOW RATE FOR THE SINK FAUCETS IS 1.8 GPM @ 60 PSI (CGC 4.303.1.4.4). <br />·AN AIR ADMITTANCE VALVE IS NOT APPROVED FOR INSTALLATION OR USE INSIDE THE DWELLING. <br />ELECTRICAL <br />ALTERATION AND/OR RENOVATION OF THE KITCHEN TRIGGER THE UPGRADE TO CURRENT ELECTRICAL CODE COMPLIANCE <br />CONSISTING OF THE FOLLOWING: <br />·ALL KITCHEN COUNTERTOP OUTLETS SHALL BE GFCI & ARC-FAULT PROTECTED (CEC 210.8(A)(6) & 210.12(A)). <br />·RECEPTACLES AND REPLACEMENT RECEPTACLES SHALL BE LISTED AS TAMPER-RESISTANT (CEC 406.4(D)(5) AND <br />210.1.2). <br />·12” OR WIDER COUNTERTOPS REQUIRE AN OUTLET (CEC 210.52(C)). <br />·OUTLETS ARE REQUIRED WITHIN 24” OF ANY LOCATION ALONG THE COUNTERTOP (CEC210.52(C)(1)). <br />·KITCHEN OUTLETS MUST BE POSITIONED A MAXIMUM 20” ABOVE COUNTERTOP (CEC 210.52(C)(3)(1)). <br />·APPLIANCE GARAGE OUTLETS ARE NOT COUNTED AS A REQUIRED COUNTERTOP OUTLETS (CEC 210.52)(C)(3)). <br />·APPLIANCES AND SINKS BREAK UP THE COUNTERTOP RUN, REQUIRING EACH SIDE TO COMPLY INDIVIDUALLY <br />(CEC210.52(C)4). <br />·ISLANDS ARE TO HAVE A MINIMUM OF ONE RECEPTACLE FOR FIRST 9 SQUARE FEET AND A SECOND RECEPTACLE FOR <br />EVERY ADDITIONAL 18 SQUARE FEET. <br />·THE ELECTRICAL OUTLET REQUIREMENTS INCLUDE ISLANDS, PENINSULAS, KITCHEN DESKTOPS, WET BARS, AND <br />SERVING BARS. A LARGE WINDOW ACROSS THE BACK OF A SINK OR LACK OF A BACK SPLASH DOES NOT EXEMPT THE <br />COUNTERTOP FROM THE OUTLET REQUIREMENTS. THESE OUTLETS MAY BE IN A DROP FRONT CABINET FACE, UNDER <br />CABINET PLUG STRIP, POP UP OR TOMBSTONE TYPE RECEPTACLE (CEC 210.52(C)(2), (3)). <br />·2 – 20 AMP SMALL APPLIANCE BRANCH CIRCUITS ARE REQUIRED FOR KITCHENS. THE LOADS SHALL BE BALANCED AND <br />HAVE NO OTHER OUTLETS (210.52(B)(1),(2)). <br />·INDIVIDUAL DEDICATED CIRCUITS ARE REQUIRED FOR ALL MAJOR APPLIANCES (210.11(C)(1) & 422.10(A)). <br />·THE GARBAGE DISPOSAL CORD IS LIMITED TO A RANGE OF 18” TO 36” LONG (CEC 422.16(B)(1)). <br />·THE DISHWASHER CORD IS LIMITED TO A RANGE OF 36” TO 78” LONG. SHEATHED CABLE (ROMEX) MAY NOT BE <br />INSTALLED WITH A PLUG. IT IS NOT AN APPROVED FLEXIBLE CORD (CEC 422.16(B)(2)). <br />·A 20 AMP BRANCH CIRCUIT MAY BE PROVIDED FOR THE DISHWASHER AND DISPOSAL (CEC 210.23). THIS RECEPTACLE <br />SHALL BE GFCI AND AFCI PROTECTED (CEC 422.5(A)(7)). <br />·A MINIMUM 20 AMP BRANCH CIRCUIT (SEPARATE CIRCUIT) IS REQUIRED FOR THE MICROWAVE OR MICROWAVE HOOD <br />COMBINATION. <br />·IF USING A SPLIT OUTLET (2 CIRCUITS ON THE SAME YOLK) FOR DISHWASHER/DISPOSAL, PROVIDE A LISTED HANDLE TIE <br />AT THE 2 CIRCUIT BREAKERS AT THE PANEL (CEC 210.7(B)). <br />·RESIDENTIAL KITCHEN LIGHTING IS REQUIRED TO MEET THE ENERGY EFFICIENCY STANDARDS. PROVIDE A LIGHTING <br />SCHEDULE TO VERIFY COMPLIANCE (150(K) CALIFORNIA ENERGY CODE). <br />·IC (DIRECT CONTACT) AND AT (AIR TIGHT) RATED CANS ARE REQUIRED FOR RECESSED LIGHTING IF INSTALLED IN AN <br />INSULATED CEILING. FOR OCCUPANCIES WITH A HORIZONTAL (FLOOR/CEILING ASSEMBLY) RATED SEPARATION, THE <br />RECESSED FIXTURES SHALL BE PROTECTED TO THE RATING OF THE SEPARATION (1 HOUR) OR BE LISTED FOR THE <br />REQUIRED PROTECTION. THIS GENERALLY APPLIES TO RESIDENTIAL CONDOMINIUM CONSTRUCTION WHERE UNITS ARE <br />ABOVE OR BELOW OTHER UNITS. (EXCEPTION FROM 150(K)(1)(CII AND III)) <br />·HIGH-EFFICACY RECESSED LIGHTING WHEN USED TO COMPLY WITH THE LIGHTING REQUIREMENTS MUST BE OF A PIN <br />BASE TYPE DESIGN. INCANDESCENT SCREW TYPE BASE ARE NOT APPROVED. <br />2X8 WD BLOCKING <br />3'-0" OR ENTIRE WALL <br />(IF LESS THAN 3'-0") <br />SIDE WALL <br />32 <br />" <br />39 <br /> <br />1 <br />/ <br />4 <br />" <br />BACK WALL <br />2X8 WD BLOCKING <br />3'-0" OR ENTIRE WALL <br />(IF LESS THAN 3'-0") <br />32 <br />" <br />39 <br /> <br />1 <br />/ <br />4 <br />" <br />·BATHROOM REMODELS WILL REQUIRE THE SMOKE AND CARBON MONOXIDE ALARMS FOR THE DWELLING TO MEET THE <br />CURRENT CODE PRIOR TO THE FINAL INSPECTION AS FOLLOWS: [CRC R314 & R315] <br />·SMOKE ALARMS ARE REQUIRED IN ALL SLEEPING ROOMS, OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY <br />OF THE BEDROOMS, ON EACH FLOOR LEVEL INCLUDING BASEMENTS AND HABITABLE ATTICS, BUT NOT INCLUDING <br />CRAWL SPACES AND UNINHABITABLE ATTICS. <br />·CARBON MONOXIDE ALARMS ARE REQUIRED IN DWELLING UNITS AND SLEEPING UNITS WHEN FUEL-BURNING <br />APPLIANCES ARE INSTALLED, AND/OR DWELLING UNITS HAVE ATTACHED GARAGES. EITHER CONDITION REQUIRES <br />ALARMS. <br />·WHEN MORE THAN ONE ALARM OF EITHER TYPE IS REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT, <br />THE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT ACTIVATION OF ONE ALARM WILL ACTIVATE <br />ALL THE OTHER ALARMS. <br />·IN EXISTING CONDITIONS, ALARMS MAY BE BATTERY OPERATED WHEN THE REPAIRS OR ALTERATIONS DO NOT RESULT <br />IN THE REMOVAL OF THE WALL AND CEILING FINISHES OR THERE IS NO ACCESS BY MEANS OF AN ATTIC, BASEMENT OR <br />CRAWLSPACE. <br />·MULTIPURPOSE ALARMS THAT COMBINE BOTH A SMOKE ALARM AND CARBON MONOXIDE ALARM SHALL COMPLY WITH <br />ALL APPLICABLE STANDARDS OF BOTH CRC SECTIONS R314 AND R315 AND BE LISTED BY THE OFFICE OF THE STATE <br />FIRE MARSHAL. <br />·SMOKE ALARMS SHALL BE LISTED IN ACCORDANCE WITH UL217. COMBINATION SMOKE AND CARBON MONOXIDE <br />ALARMS SHALL BE LISTED IN ACCORDANCE WITH UL217AND UL2034. <br />·SMOKE ALARM SHALL NOT BE INSTALLED LESS THAN 3 FEET HORIZONTALLY FROM THE DOOR OR OPENING OF A <br />BATHROOM THAT CONTAINS A BATHTUB OR SHOWER [R314.3] <br />627 S Shelton St & <br />#212/4/2024