Project : <br />Project Number : <br />By : <br />Date : <br />Allen Jensen <br />PE <br />04-29-2025 <br />Check for Increase in overall seismic loads <br />Module Area =ft2 <br />Number of Modules = <br />Total Array Area =ft2 <br />Array Load = psf <br />Number of Existing Modules = <br />Existing Array Area =ft2 <br />Total Array Wt. = lb <br />Total Roof Area =ft2 <br />DL of Roof = psf <br />Total Wt of Roof = lb <br />Increase in Seismic Wt = < 10% <br />Conservatively the Wt. of the Walls tributary to the roof is not included. Seismic weight increase is less than <br />10% and no seismic retrofit or evaluation of existing lateral system is required per Section 503.4 of 2022 <br />CEBC. <br />21.0 <br />8 <br />168.18 <br />3261 <br />3.00 <br />2386.5 <br />30 <br />627.33 <br />13.74 <br />44806 <br />5.3% <br />Page 14