Laserfiche WebLink
CITY OF SANTA ANA <br />ENPHASE <br />IQ Combiner 5/5C <br />The IQ Combiner 5/5C consolidates Interconnection equipment Into a single enclosure and <br />streamlines 10 Series Microinverters and 10 Gateway Installation by providing a consistent. <br />pre -wired solution for residential applications. 10 Combiner 5/5C uses wired control <br />communication and is compatible with 10 System Controller 3/3G and IC Battery 5P. <br />The 10 Combiner 5/5C, 10 Series Microinverters, 10 System Controller 3/3G, and <br />10 Battery 5P provide a complete grid -agnostic Enphase Energy System. <br />IQ Seri es Microinverters 10 System Controller 3/3G <br />The high-powered smart grid -ready lO Series Provides mlorogrid interconnection device <br />Microinverters(106. 107. and 108 Series) (MID) functionality by automatically detecting <br />simplify the installation process. grid failures and seamlessly transitioning <br />the home energy system from grid power to <br />backup power. <br />10 Battery SIP 10 Load Controller <br />Fullyinte9rated AC battery system. Includes Helps essential appliances <br />ces during, <br />six field -replaceable IQ8D-BAT Microinverters. grid outage to optimize energy consumption <br />and prolong battery life. <br />[I NOM <br />5-year limited warranty <br />'Fit co retry-spetltk wananty Information, sae the https//enpha,aoomAnatellenhewurces/warranty page <br />e a32a Enphase Enemµ Aprighermrved Enphase, the a end cc Iagoa ld ands other mart paled al <br />h._."enolu.recant/tMameh-unto-sultlellnasan trsdemvk of Enphue Enaley.lnc In the US.ard onion wularla <br />ceaabled b dung, <br />IQ Combiner 5/5C <br />IQ Combiner 5 with IQ Gateway printed circuit board for integrated revenue -grade PV <br />IQ Combiner 5(X-IQ-AMI-240-5) production metering (ANSI C12.20±0.5%). consumption monitoring Q2.5%). and IQ <br />Battery monitoring (±2.5%). Includes a silver solar shield to deflect heat <br />10 Combiner SC with 10 Gateway primed circuit board for integrated revenue -grade <br />IQ Combiner 5C(X-I0-AW-240-5C) PV production metering (ANSI C12.20±0.5%), consumption monitoring (±2.5%), and <br />10 Battery monftoring (±25%). Includes Enphase Mobile Connect cellular modem <br />(CELLMODEM-MI-06-SP-05)'. Includes a silver solar shield to deflect heat. <br />IQ Gateway printed circuit board <br />IQ Gateway is the platform for total energy management for comprehensive. remote <br />maintenance and management of the Enphase Energy System <br />Busbar <br />80 A busbar with support for one 10 Gateway breaker and four 20 A breakers for <br />installing 10 Series Microinverters and 10 Battery SIP <br />10 Gateway breaker <br />Circuit breaker. 2-pole. l0 A/15 A <br />X-10-AM11-240-5 <br />Production CT <br />Pre -wired revenue -grade solid -core CT. accurate up to±0.5% <br />X-M-AM7-240-5C <br />Consumption CT <br />Two consumption metering clamp CTs. shipped with the box, accurate up to±2.5% <br />IQ Battery CT <br />One battery metering clamp CT, shipped with the box, accurate up to±25% <br />CTRL board <br />Control board for wired communication with 10 System Controller 3/3G and the <br />IQ Battery 5P <br />Smart <br />Enphase Mobile Connect (only with lO Combiner 5C) <br />41based LTE-MI cellular modem (CELLMODEM-MI-06-SP-05) with a 5-year T-Mobile <br />data plan <br />• Includes 10 Gateway for <br />communication and control <br />Accessories kit <br />Spare control headers for the COMMS-KIT-2 board <br />• Includes Enphase Mobile Connect <br />ACCESSORIESrINCLUDED, <br />ORDER <br />(CELLMODEM-Mt-06-SP-05). only <br />with IQ Combiner SC <br />CELLMODEM-Ml-06-SP-05 <br />4G-based LTE-MI cePular modem with a 5-year T-Mobile data plan <br />• Supports flexible networking: WI-Fi, <br />CELLMODEM-MI-06-AT-05 <br />4Gbased LTE-Mt cellular modem with a 5-year AT&T data plan <br />Ethernet, or cellular <br />Supports Eaton BR2XX. Siemens Q2XX. and GE/ABB THOL21XX Series circuit breakers <br />• Provides production metering <br />Circuit breakers(off-the-shelf) <br />(XX represents 10. 15.20.30.40.50. or 60). Also supports Eaton BR22013, BR230B, and <br />(revenue grade) and consumption <br />BR240B circuit breakers compatible with the hold-down kit <br />monitoring <br />Circuit breakers (provided by Enphase) <br />BRK-10A-2-240V, BRK-15A-2-240V. BRK-20A-2P-240V, BRK-15A-2P-240V-B, and <br />BRK-20A-2P-24OV-B (more details in the "Accessories" section) <br />Easy to install <br />• Mounts to one with centered <br />XA-SOLARSHIELD-ES <br />Replacement solar shield for IQ Combiner 5/5C <br />brackets <br />XA-ENV2-PCBA-5 <br />10 Gateway replacement printed circuit board (PCB) for 10 Combiner 5/5C <br />• Supports bottom, back. and side <br />X-I0-NA-HD-125A <br />Hold-down kit compatible with Eaton BR-B Series circuit breakers (with screws) <br />conduit entries <br />XA-COMMS2-PCBA-5 <br />Replacement COMMS-KIT-2 printed circuit board (PCB) for IQ Combiner 5/5C <br />• Supports up to four 2-pole branch <br />circuits for 240 VAC plug-in breakers <br />ELECTRICAL SPECIFICATIONS <br />(rot included) <br />Rating <br />BOA <br />• 80 A total PV branch circuits <br />System voltage and frequency <br />120/240 VAC or 120/208 VAC, 60 W <br />• Bluetooth-based WI-Fl provisioning <br />for easy Wi-Fi setup <br />Busbar rating <br />125 A <br />Fault current rating <br />tO kAIC <br />Reliable <br />Maximum continuous current rating <br />64A <br />• Durable NRTL-certified NEMA type 3R <br />(Input from PV/storage) <br />enclosure <br />Branch <br />Up to four2-poleEaton BR. Siemens Q,or GE/ABB THOL Series distributed generation <br />• 5-year limited warranty <br />and/or storage) <br />g <br />(DG) breakers only (not included) <br />• 2-year labor reimbursement program <br />Maximum total branch circuit breaker rating(input) <br />80 A ofdistributed generation/95 A with 10 Gateway breaker included <br />coverage included for both the <br />10 Combiner SKUs' <br />10 Gateway breaker <br />10 A or 15 A rating GE/Siemens/Eaton Included <br />• UU741 Listed <br />production metering CT <br />200 A solid core pre -Installed and wired to 10 Gateway <br />Consumption monitoring CT (CT-200-CLAMP) <br />A pair of 200 A clamp -style current transformers is included with the box <br />10 Battery metering CT <br />200 A clamp -style current transformer for 10 Battery metering, included with the (cox <br />`A plugs xs, Ind, -1-ersde-ndd.brgalamaof up Io eO mtmYaene, MalYbY Y IIa UNIed SLLIm, Onada, x IoP. guano Rko, ud the us Vhgin YYnda,wlrm (hare v, atlequala <br />callus r ae- In the InaLLlYtlon a ua. <br />gGs�aC-DSH-000W-SA-EN-US-202<-08-16 IFS-SC-OSH-000m-SA-EN-US2Vl1-0a-1a <br />Planning and Building Agen <br />CMP0\VE:R <br />AR WRY&4 <br />Fj DR PFI PT��SUANC1 <br />CLOVIS, CA 93611 <br />TEL: (800) 306 6953 <br />CSLB:1057693 <br />Email: permits@mpwrsolar.com <br />Master ID: <br />MECHANICAL 3• <br />C-10 #1057693 <br />Dimensions (W - H - D) <br />37.5 cm a 49'5 cm a 16.8 cm (14.75" • 19.5" - 6.63"). <br />Height is 53.5 cm(21.06-) with mounting brackets. <br />Scoff Forster <br />Weight <br />7.5 kg (16.5 lb) <br />VERSION <br />Ambient temperature range -40•C to 46"C (-40'F to 115'F) <br />Cooling <br />Natural convection. plus heat shield <br />DESCRIPTION <br />DATE <br />REV <br />Enclosure emrironmentel rating <br />Outdoor, NRTL-certified, NEMA type 3R, polycarbordate construction <br />INITIAL RELEASE <br />03.07-2025 <br />UR <br />- <br />• reakerin u%:14to4AWGco <br />2OAto5OAb p pper conductors <br />• 60 A breaker branch input 4 to 1/0 AWGcopper conductors <br />Wire sizes <br />Main lug combined output. 10 to 2/0 AWG copper conductors <br />• Neutral and ground: 14 to 1/0 copper conductors <br />• Always follow local code requirements for conductor string <br />Built-in CTRL board for wired communication with the 10 Battery 5P and the <br />Communication(in-premiseconnectivity) <br />10 System Controller 3/3G. Integrated power line communication for lO Series <br />Mi-inverters. <br />Altitude <br />Up to 2,600 meters (8,530 feet) <br />Integrated W i-F1 <br />802.11b/g/n (dual band 2A GHz/5 GHz) for connecting the Enphase Cloud through <br />the internet. <br />WI -FT range (recommended) <br />10 m (32.8 feet) <br />Bluetooth <br />BLE4.2. 10 m range to configure WI-R SSID <br />Ethernet <br />Optional. 802-3. Cat5E (or Cat 6) UTP Ethernet cable (not Included) for connecting to <br />the Enphase Cloud through the internet. <br />Cellular/Mobile Connect <br />CELLMODEM-Mt-06-SP-05 or CELLMODEM-Mt-06-AT-05 (included with the <br />10 Combiner 5C) <br />Digital I/O <br />Digital input/output for grid operator control <br />USB 2.0 <br />Mobile Connect. COMMS-KIT-01 for 10 Battery 3/3r/10/10T. COMMS-KIT-02 for <br />IQ Battery 5P <br />PROJECT NAME <br />Access point (AP) mode <br />For connection between the 10 Gateway and a mobile device running the <br />Enphase Installer App <br />z <br />Metering ports <br />Up to two Consumption CTs, one 10 Battery CT, and one Production CT <br />Power line communication <br />90-110 kHz <br />O <br />Web API <br />See httos://developer-v4.ewhase com <br />0 <br />Local APT <br />See Guide for local API <br />Lij <br />l <br />Q <br />Q <br />D z <br />UL 1741, CAN/CSA C22.2 No. 107.1, Title 47 CFR, Part 15, Class B. ICES 003, <br />10 Combiner with lO Gateway <br />NOM-208-SCFI-2016, UL 61010-1,CAN/CSA 22.2 No. 61010-1,IEEE 1547:2018(UL <br />L ry <br />IY <br />1741-SB, 3td Ed.), IEEE 2030.5/CSIP Compliant, Production metering: ANSI CIZ20 <br />> � <br />0 <br />accuracy class 0.5(PV production) <br />LZ Q O <br />00 <br />Z U (M J N <br />z LL Q (D <br />COMPATIBILITY <br />PV Microinverters 106, IQ7, and 108 Series Microinverters <br />U w <br />IQ System Controller <br />EP200G101-M240US00 <br />z U <br />COMMS-KIT-Olr <br />10 System Controller 2 <br />EP200G1o1-M240US01 <br />Q rzy coo <br />IZ <br />IQ Battery <br />A, ENCHARGE-3-IP-NENCHARGE-10-1P-NA, ENCHARGE-3TAP-NA, <br />ENCHARGE-10T-1P-NA <br />Q <br />LLLLI <br />(f) z LU z <br />_) <br />J I,- Q = <br />IQ System Controller 3 <br />SC200D111C24OUS01. SC20OG11IC24OUSOI <br />Q Q <br />COMMS-KIT-023 <br />10 Battery <br />IOBATTERY-5P-IP-NA <br />- Q <br />`ozl0^ <br />-For lnformationaboutlGOombiner5/5C the2n0-9ereratlanbattenes.rafer <br />to Us2QMgtlbMy-trix <br />Q U) <br />compMlNlltywith <br />310 Combiner 5/SC come, pro-egWpped with COMMa-KIT-02 <br />(%) <br />_J <br />xtc-s-50- W H-000m-SA-EN-US-idol-ce lis <br />D <br />SHEET NAME <br />SPEC SHEETS <br />SHEET SIZE <br />ANSI B <br />1111 X 17" <br />SHEET NUMBER <br />PV-8 <br />