Laserfiche WebLink
General Footing <br />LIC# : KW-06015195, Build:20.22.1.12 TA Structural (c) ENERCALC INC 1983-2021 <br />DESCRIPTION:typ. spread footing <br />Project File: 39473 Sundale_FLR Framing_Calcs.ec6 <br />Project Title: <br />Engineer: <br />Project ID: <br />Project Descr: <br />PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding <br />PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding <br />DESIGN SUMMARY Design OK <br />Governing Load CombinationMin. Ratio Item Applied Capacity <br />PASS 0.9787 Soil Bearing 1.468 ksf 1.50 ksf +D+L about Z-Z axis <br />PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning <br />PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning <br />PASS n/a Uplift 0.0 k 0.0 k No Uplift <br />PASS 0.03537 Z Flexure (+X)0.9250 k-ft/ft 26.153 k-ft/ft +1.20D+1.60L <br />PASS 0.03537 Z Flexure (-X)0.9250 k-ft/ft 26.153 k-ft/ft +1.20D+1.60L <br />PASS 0.03537 X Flexure (+Z)0.9250 k-ft/ft 26.153 k-ft/ft +1.20D+1.60L <br />PASS 0.03537 X Flexure (-Z)0.9250 k-ft/ft 26.153 k-ft/ft +1.20D+1.60L <br />PASS n/a 1-way Shear (+X)0.0 psi 75.0 psi n/a <br />PASS 0.0 1-way Shear (-X)0.0 psi 0.0 psi n/a <br />PASS n/a 1-way Shear (+Z)0.0 psi 75.0 psi n/a <br />PASS n/a 1-way Shear (-Z)0.0 psi 75.0 psi n/a <br />PASS n/a 2-way Punching 5.062 psi 75.0 psi +1.20D+1.60L