SCALE: 1' = 1/8" <br />PHOTOVOLTAIC SYSTEM <br />Installation of <br />8.40 KW Grid Tied <br />Photovoltaic System <br />& 13.5 kWh Battery <br />Solar Individual <br />Permit Package <br />DATE DRAWN <br />DRAWN BY <br />SCALE <br />NAREK Y. <br />AS INDICATED <br />SHEET <br />Rev Description Date <br />01.07.25 <br />CONTRACTOR <br />California Solar & <br />Electric, Inc. <br />Address: <br />26074 Avenue Hall Ste 13 <br />Santa Clarita, CA 91355 <br />Phone Number: <br />Tel:(628)998-4928 <br />CSLB License #1073677 <br />Class C-10 <br />Contractor Signature <br />SYSTEM SIZE (DC): <br />STC: 20 X 420 = 8.40kW DC <br />PTC: 20 X 402.5 = 8.05kW DC <br />SYSTEM SIZE (AC): <br />11.5kW AC <br />DAVID SMITH <br />825 N Lacy St, Santa <br />Ana, CA 92701 <br />A1 <br />(N) 20 REC SOLAR 420W PV MODULES <br />MODEL # : REC420AA PURE-R <br />(N) 8 MCI-1 RSD <br />(N) 1 TESLA POWERWALL 3 <br />MODEL # : 1707000-XX-Y <br />1.The ESS Systems shall be separated from doors, <br />windows, operable openings into buildings, or HVAC <br />inlets by at least 5 feet. <br />2.Conduit will run over the roof at 1-1/2" height from the <br />roof surface. <br />3.Conduit will be painted to match roof color. <br />NOTES <br />This schedule reflects the minimum number of disconnects <br />required to disconnect all electrical power sources from the <br />circuitry of the structure. <br />ELECTRICAL POWER SOURCE DISCONNECT SCHEDULE <br />Utility Service 1 of 1 200A Main Breaker <br />Energy Sourcea Disconnection Number <br />(#X of Y)b <br />Disconnection <br />Operation/Equipment/ <br />Devicec <br />MSP <br />UMR <br />ESS <br />N L <br />a <br />c <br />y <br /> <br />S <br />t <br />(N) Solar PV Array 1 <br />10 REC Solar 420W <br />4 MCI-1 RSD <br />18 Deg Roof Slope <br />Orientation: 154 Deg <br />(N) Solar PV Array 1 <br />10 REC Solar 420W <br />4 MCI-1 RSD <br />18 Deg Roof Slope <br />Orientation: 334 Deg <br />(N) Tesla Powerwall 3 <br />(E) 200A Main Service Panel <br />(Disconnect 1 of 1) <br />(E) Utility Meter <br />(N) Tesla Backup Switch <br />(N) System Shutdown <br /> Switch (RSD) <br />JB <br />(N) NEMA 3R Junction Box <br />Gate <br />Detached Garage <br />(Non-Habitable) <br />a <br />MCI <br />a <br />MCI <br />b <br />MCI bMCI <br />MCI <br />MCI <br />MCI <br />MCI <br />c <br />c <br />d <br />d <br />EMT Type Conduit <br />12/31/25 <br /> <br /> <br /> <br /> <br /> <br /> <br />STAMPED FOR <br />EXISTING ROOF AND <br />ATTACHMENT ONLY <br />HISTORIC-825 N <br />Lacy St2/18/2025