CITY OF SANTA ANA <br />Planning and Building Agency <br />2. CONCRETE FOUNDATION CONSTRUCTION <br />200. THE FIELD INSPECTOR SHALL VERIFY FOUNDATION REQUIREMENTS DURING FOUNDATION INSPECTION <br />201. CONCRETE STRENGTH SHALL BE NO LESS THAN 2,500 PSI @ 28 DAYS, OR HIGHER STRENGTH IF NOTED <br />ON THE PLANS. <br />202. SLAB REINFORCEMENT & FOOTINGS SHALL BE PER STRUCTURAL DETAILS ON SHEET S4, CENTERED IN SLAB. <br />203. <br />REINFORCING BARS TO BE GRADE 40 FOR #3 BARS, GRADE 60 FOR #4 BARS &LARGER <br />204. PROVIDE WEAKENED PLANE JOINTS FOR CRACK CONTROL (SAWCUT OR TOOLED JOINT) AT <br />144" O/C MAX. <br />205. SILL ANCHORAGE ATALL SHEARWALL LOCATIONS SHALL BE PER THE SHEARWALL SCHEDULE. <br />ALL SHEARWALL ANCHOR BOLTS SHALL RECEIVE A 3" SQUARE X 0.229" THICK WASHER. THE <br />WASHER MAYBE DIAGONALLY SLOTTED (WIDTH >= BOLT DIAMETER + 3/16", LENGTH<=1 1") <br />PROVIDED THATA STANDARD CUT WASHER IS USED ON TOP OF THE SQUARE WASHER. <br />SHEARWALL ANCHORS SHALL BE PLACED A MIN. OF 1 1" FROM THE EDGE OF CONCRETE. <br />206, EMBEDDED SILL ANCHOR BOLTSATTYPICAL NON-SHEARWALL CONDITIONS SHALL BE <br />a " DIA. MIN. ANCHOR BOLTS WITH A STANDARD CUT WASHER. SPACING SHALL NOT <br />EXCEED 48 INCHES O/C. LOCATE AN ANCHOR BOLT NOT MORE THAN 9 INCHES, OR <br />LESS THAN 4" FROM ENDS AND SPLICES. EACH SILL SHALL HAVE (2) SILL BOLTS MIN, <br />207. ANCHOR BOLTS SHALL BE EMBEDDED A MIN. OF 7 INCHES INTO CONCRETE. IN A <br />TWO -POUR SYSTEM, ANCHOR BOLTS TO BE EMBEDDED 5 INCHES MIN. INTO FIRST POUR. <br />208. SEE WOOD FRAMING CONSTRUCTION NOTES FOR ALTERNATE SILL ANCHORAGE. <br />209. ALL HOLDOWNS SHALL BE PLACED A MINIMUM DIM AS SHOWN IN DETAIL 3&4/S4 FROM <br />EXTERIOR CORNER OF SLAB. <br />210. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS. SUBCONTRACTOR TO VERIFY <br />ALL DIMENSIONS PRIOR TO CONSTRUCTION. IMMEDIATELY NOTIFY HOMEOWNER AND <br />CITY OF SANTAANA OF ANY DISCREPANCY, TYPICAL. <br />211. PROVIDE A UFER GROUND FOR ELECTRICAL SYSTEM PER ARTICLE 250.52 N.E.C. <br />212• ALL SURROUNDING FLAT WORK SHALL BE VERIFIED WITH HOMEOWNER FOR LOCATION AND <br />AMOUNT TO BE POURED. <br />213. RETROFIT MISPLACED HOLDOWNS AS NOTED BELOW. AT EPDXY ANCHORS USE SIMPSON <br />SET-XP EPDXY PER MANUFACTURERS <br />INSTALLATION REQUIREMENTS <br />AS FOLLOWS: <br />MISPLACED HOLDOWN <br />RETROFIT BOLT <br />REPLACEMENT HARDWARE <br />LSTHD8, HTT4 <br />a " ALL -THREAD, EMBED 9" <br />HTT4 <br />STHD10, STHD14, HTT5 <br />5, " <br />8 ALL -THREAD, EMBED 9 <br />HTT5 <br />LTT20B <br />a "ALL -THREAD, EMBED 7" <br />LTT20B <br />LTT20B <br />ATTACH TO EXISTING A.B. <br />LTT20B <br />HDU8 <br />a"ALL-THREAD, EMBED 15" <br />HDU8 <br />214. RETROFIT ¢" & a " EMBEDDED ANCHOR BOLTS AS NOTED BELOW. AT EPDXY <br />ANCHORS USE SIMPSON SETAP EPDXY PER SIMPSON'S INSTALLATION REQUIREMENTS. <br />LOCATION TYPE REPLACEMENT <br />SLAB EDGE, 1.314"DIST. SHEARWALL a " ALL -THREAD, EPDXY, EMBED 3" <br />OR a " TITEN HD, EMBED 3" MIN. <br />INTERIOR > 6," EDGE DIST. SHEARWALL OR s TITEN HD, EMBED 3" MIN. <br />NON -SHEAR <br />ANY OTHER NON SHEAR 0.145 DIA. SHOT PINS SPACED 4 INCHES <br />APART ON SILL. (2) FOR EACH MISSING <br />ANCHOR BOLT. MAX. OF (6) SHOT PINS <br />EVERY 6 FT. <br />215. WHEN REQUESTING A BUILDING DEPARTMENT FOUNDATION INSPECTION, HAVE CONTRACTOR <br />DOCUMENTATION IN WRITING FOR THE FOLLOWING: <br />A) THE PAD WAS PREPARED IN ACCORDANCE WITH THE SITE REQUIREMENTS AND CITY OF <br />SANTA ANA APPROVAL. <br />B) THE UTILITY TRENCHES HAVE BEEN PROPERLY BACKFILLED & COMPACTED. <br />C) THE FOUNDATION EXCAVATIONS, EXPANSIVE CHARACTERISTICS AND BEARING <br />CAPACITY COMPLIES WITH THE CITY OF SANTAANA RECOMMENDATIONS <br />216. ALL HOLDOWN ANCHORS & HARDWARE MUST BE TIED IN PLACE PRIOR TO CALLING FOR <br />A FOUNDATION INSPECTION. <br />3. WOOD FRAMING CONSTRUCTION <br />300. ROOFING MATERIALS SHALL BE PER ARCHITECTURAL DRAWINGS. <br />301, ROOF SHEATHING SHALL BE 32 " OR a " C-D GRADE, INTERIOR TYPE PLYWOOD <br />WITH EXTERIOR GLUE, OR OSB PANELS. IDENTIFICATION INDEX (24/0) W/ 8D <br />COMMON NAILS @ 6" O/C @ ALL PERIMETER EDGES AND ALL INTERIOR SUPPORTED <br />EDGES AND @ 12" O/C @ ALL INTERMEDIATE SUPPORTS. SEE DETAILS FOR SHEAR AND <br />DRAG NAILING. <br />302. TYPICAL WALL SHEATHING: <br />INTERIOR SURFACES: WHERE DRYWALL IS SPECIFIED, PROVIDE MIN. $" GYPSUM <br />WALLBOARD W/ 5D COOLER NAILS OR EQUAL @ 7" O/C TO ALL STUDS AND TO TOP & <br />BOTTOM PLATES (UNBLOCKED) AT INTERIOR SIDE OF EXTERIOR WALLS AND AT BOTH <br />SIDES OF ALL INTERIOR WALLS. <br />EXTERIOR SURFACES: SEE PLANS. WHERE "STUCCO" IS SPECIFIED PROVIDE 8" <br />EXTERIOR CEMENT PLASTER OVER WIRE LATH OVER TYPE 15 BUILDING PAPER. <br />LATH ATTACHED TO ALL STUDS AND TOP AND BOTTOM PLATES (OR BLOCKING AS <br />OCCURS) W/ 16 GAGE X 16 STAPLES @ 6" O/C OR NO. 11 GAGE X 1-112" <br />FURRING NAILS WHERE INDICATED ON ELEVATIONS. <br />303. STRUCTURAL SHEATHING MAY BE EITHER OSB OR PLYWOOD. ANY NOTES REFERRING TO <br />PLYWOOD ALSO APPLIES TO OSB, <br />304. TOP PLATES SHALL BE DOUBLE 2X W/ WIDTH EQUAL TO STUDS BELOW, W/ (21)16D NAILS <br />MIN. @ MINIMUM 4'-0" LAP SPLICES. USE SIMPSON RPS OR CS16 STRAP EACH <br />SIDE OR ONE SIDE AND TOP WHERE LAP SPLICE IS NOT POSSIBLE. SEE DETAILS FOR <br />NOTCHES, CUT-OUTS AND COMPLETE PLATE BREAKS AT HEATING, VENTING, AND PLUMBING <br />3. WOOD FRAMING CONSTRUCTION (CONT.) <br />305. TYPICAL SHEAR TRANSFER: <br />ROOF TO WALL: CONNECT ROOF FRAMING TO TOP PLATE W/ SIMPSON H1 @ 24" O/C <br />OR A35 OR RBC @ 24" O/C OR PER SHEAR TRANSFER DETAILS. <br />SILL PLATE ANCHORS: <br />306. <br />GROUND FLOOR 1 SLAB ON GRADE WALLS: PROVIDE 2X MIN. PTDF SILL PLATES. <br />SEE CONCRETE FOUNDATION CONSTRUCTION NOTES 206, 207 & 208 FOR ANCHOR <br />BOLTS. AT INTERIOR NON -SHEAR CONDITIONS, 0.145 SHOT PIN ANCHORS @ 32" O/C <br />MAY BE USED TO CONNECT PARTITIONS AND BEARING WALLS TO SLAB. <br />307. ALL WOOD SILL PLATESAND ALL WOOD MEMBERS DIRECTLYAGAINST CONCRETE OR <br />MASONRY SHALL BE FOUNDATION GRADE REDWOOD SILLS OR PTDF SILLS, TREATED WITH <br />SODIUM BORATE (SBX/DOT) WHEN INSTALLED IN A DRY OR ENCLOSED ENVIRONMENT. <br />(SODIUM BORATE TREATMENT DOES NOT REQUIRE CORROSION RESISTANT CONNECTORS.) <br />IF OTHER TREATMENTS ARE USED, SEE NOTE 309. <br />308. FASTENERS IN CONTACT WITH PRESSURE TREATED WOOD: <br />ALL NAILS AND FASTENERS IN CONTACT WITH PRESSURE TREATED LUMBER TREATED WITH <br />ACQ-C, ACQ-D, CA-B, AND CBA-A WITHOUT AMMONIA SHALL BE GALVANIZED PER <br />ASTM Al53. <br />ALL NAILS AND FASTENERS IN CONTACT WITH PRESSURE TREATED LUMBER TREATED WITH <br />ACQ-C, ACQ-D, CA-B, AND CBA-A WITH AMMONIA SHALL BE TYPE 303, 304, 305, <br />OR 316 STAINLESS STEEL. <br />WHERE PRESSURE TREATED LUMBER IS INSTALLED IN AN EXTERIOR WET ENVIRONMENT, <br />ALL NAILS AND FASTENERS IN CONTACT WITH THE PRESSURE TREATED LUMBER SHALL BE <br />TYPE 303, 304, 305, OR 316 STAINLESS STEEL. <br />309. RE -TIGHTEN ALL HOLDOWN ANCHORS JUST PRIOR TO COVERING THE WALL FRAMING. <br />310. ENGINEERED BEAMS AREAS FOLLOWS: <br />"PSL" REFERS TO PARALLEL STRAND LUMBER (E=2.0, FB=2900). <br />"LSL" REFERS TO LAMINATED STRAND LUMBER (E=1.55, FB=2325). <br />(E=1.3 & FB=1700 AT LSL CONDITIONS WITH D (DEPTH) < 9" ) <br />"LVL" REFERS TO LAMINATED VENEER LUMBER (E=2.0, FB=2800). <br />"GLB" REFERS TO 24F-1.8E GLU-LAM WITH STANDARD CAMBER, U.N.O. <br />"IJC" ENGINEERED GLU-LAM BEAM MAYBE USED UPON ENGINEER APPROVALS. <br />AN A.I.T.0 CERTIFICATE OF COMPLIANCE ISSUED BY A CURRENT ICC <br />APPROVED QUALITY CONTROL AGENCY FOR GLUED LAMINATED WOOD MEMBERS <br />SHALL BE GIVEN TO THE BUILDING INSPECTOR PRIOR TO INSTALLATION. <br />311. LUMBER SPECIFICATIONS: <br />ALL FRAMING LUMBER SHALL BE DOUGLAS FIR -LARCH. STUDS, PLATES & BLOCKING: <br />2X4 FRAMING LUMBER NOT LISTED BELOW STANDARD GRADE OR BETTER <br />92-1/4", 104-1/4", & 116-1/4"2X4 STUDS STUD GRADE OR BETTER <br />2X4 STUDS OVER 10' #2 OR BETTER <br />2X4 SILLS & PLATES STANDARD OR BETTER <br />2X6 STUDS, SILLS, & PLATES #2 OR BETTER <br />4X4 STUDS & POSTS STANDARD OR BETTER OR #1 <br />4X6, 6X6, & LARGER STUDS & POSTS #1 OR BETTER <br />4X4, 4X6 BEAMS & HEADERS #2 OR BETTER <br />4X8, 4X10, 4X12, 4X14 BEAMS & HEADERS #1 OR BETTER <br />6X4 BEAMS & HEADERS <br />#2 OR BETTER <br />6X6 & LARGER BEAM & HEADERS #1 OR BETTER <br />2X6 AND LARGER RAFTERS AND JOISTS #2 OR BETTER <br />312. HOLES, CUTOUTS, AND NOTCHES IN FRAMING MEMBERS: <br />BY VIRTUE OF CODE COMPLIANCE WITH ELECTRICAL AND PLUMBINGDE CODES, HOLES <br />AND NOTCHES WILL INEVITABLYBE MADE IN FRAMING MEMBERS, THE CODE <br />RECOGNIZES AND APPROVES VARIOUS HOLES AND NOTCHES WITHOUT ENGINEERING <br />JUSTIFICATION IN CBC SECTION 2308.8.2. ENGINEERED (PSL, LSL) RECTANGULAR <br />LUMBER BEAMS BEHAVE LIKE ANY OTHER RECTANGULAR SHAPE WHEN NOTCHED OR <br />BORED, SO THE ENGINEER OR ARCHITECT MAY SPECIFY LIMITS WITHOUT MANUFACTURER <br />APPROVAL OTHER HOLES AND NOTCHES ARE ALLOWED AS NOTED BELOW: <br />PSL AND LVL BEAMS: A HOLE 1 INCH IN DIAMETER CAN BE DRILLED ANYWHERE, <br />AND A 2 INCH DIA. HOLE CAN BE DRILLED IN THE MIDDLE THIRD OF THE SPAN IN <br />THE MIDDLE THIRD OF THE DEPTH OF THE BEAM FOR ANY PSL OR LVL BEAM, <br />EXCEPT CANTILEVERED BEAMS AND BEAMS SUPPORTING CONCENTRATED LOADS. <br />HOLES IN THOSE CONDITIONS REQUIRE APPROVAL IN WRITING FROM THE ENGINEER <br />PSLAND LVL BEAMS: A RAKE CUT (TAPER)ATTHE TOP OF THE BEAM ATTHE <br />END OF THE SUPPORT IS ALLOWED IF NOTED ON PLANS, TO A <br />MINIMUM OF 4-3/8" AT INSIDE FACE OF SUPPORT. RAKE CUT (TAPER) THAT <br />RESULTS IN A DEPTH AT THE INSIDE FACE OF THE SUPPORT OF 2/3RDS THE <br />BEAM DEPTH IS ALLOWED AT CONDITIONS NOT SPECIFIED. OTHER TAPERED <br />ENDS AND SQUARE NOTCHES IN TOP OR BOTTOM FACE REQUIRE APPROVAL IN <br />WRITING FROM THE ENGINEER OR ARCHITECT. <br />STUDS AND PLATES: SEE STRUCTURAL DETAILS 13 & 14 ON SHEET S3 FOR NOTCHING <br />AND BORING, <br />313. PROVIDE 2X4 TRIMMER & 2X4 KING STUD EACH END OF EACH 4X DROPPED BEAM <br />OR HEADER. PROVIDE DOUBLE TRIMMERS AT EACH 4X10 OR LARGER. PROVIDE DOUBLE <br />TRIMMERS AT EACH 3-1/2 X 7-1/2 PSL OR LSL OR LARGER. <br />314. PROVIDE 2X6 TRIMMER & 2X6 KING STUD EACH END OF EACH 6X DROPPED BEAM <br />OR HEADER. PROVIDE DOUBLE TRIMMERS AT EACH 6X8 OR LARGER. PROVIDE DOUBLE <br />TRIMMERS AT EACH 5-1/4 X 7-1/2 PSL OR LSL OR LARGER. <br />315. PROVIDE DOUBLE KING STUDS ATALL OPENINGS 8'-l" WIDE AND WIDER OR PER PLAN. <br />316. PROVIDE MINIMUM 2-1/4" BEARING @ EACH END OF EACH FLUSH BEAM OR HEADER <br />WHERE BEARING IS ON TOP PLATE. PROVIDE 2X4 STUD WITHIN 3" OF BEARING POINT. <br />PROVIDE (2) 2X STUDS @ 6X OR LSL OR PSL BEAMS. <br />317. ROOF RAFTERS SHALL BE 2X RAFTERS AS NOTED ON STRUCTURAL DRAWINGS <br />318. EAVES SHALL BE PER ARCHITECTURAL PLANS W/ APPLIED TAILS PER ARCHITECTURAL <br />PLANS. OVERHANG DETAILSARE NOT SHOWN ON STRUCTURAL PLANS. <br />319. SEETHE ARCHITECTURAL ROOF PLANS FOR ROOF PITCH AND ADDITIONAL INFORMATION. <br />320. COMBINE AND GROUP PLUMBING VENTS WHENEVER POSSIBLE TO MINIMIZE ROOF <br />PENETRATIONS. <br />3. WOOD FRAMING CONSTRUCTION (CONT.) <br />321. WOOD TO WOOD CONNECTORS SHALL BE SIMPSON STRONG TIE OR USP STRUCTURAL <br />CONNECTORS. ALL SPECIFIED CONNECTOR CALL -OUTS ARE SIMPSON CATALOG CALL -OUTS <br />USP SUBSTITUTIONS SHALL HAVE A CAPACITY EQUAL TO OR GREATER THAN THE SIMPSON <br />CATALOG VALUES. ANY OTHER ICC APPROVED METAL CONNECTOR MAY BE USED UPON <br />APPROVAL BY THE ENGINEER OR ARCHITECT. <br />322• ICC APPROVED CONNECTORS SHALL BE USED WHERE CONNECTORS ARE SPECIFIED, <br />UNLESS OTHERWISE NOTED, THE FOLLOWING BEAM AND JOIST HANGERS SHALL BE USED: <br />BEAM OR JOIST SIMPSON/USP HANGER <br />I -JOIST FLOOR JOISTS IUS, IUT, OR ITT HANGERS <br />1.75 X LSL AND LVL HU, HUS, OR WPU <br />2.69 X PSL AND LVL HU OR HWU <br />3.5 X PSL AND LVL HHUS OR HWU <br />5.25 X PSL AND LVL HHUS OR HWU <br />7 X PSL AND LVL HHUS OR HWU <br />AT BEAM HANGER CALLOUTS, IE HGUS OR HU BEAMS, THE CALLOUT IS ABBREVIATED, <br />THE HANGER WIDTH MAYBE OMITTED TO ALLOW FLEXIBILITY IN ORDERING. EXAMPLE: 2.69 PSL <br />THE CALLOUT MAY READ HGUS12. AN HGUS2.75/12 OR HGUS412 (WITH FILLERS) <br />ARE APPLICABLE, WHERE HANGERS OFFER (MIN) OR (MAX), NAIL TO APPLY (MAX) LOADS. <br />323. WHERE SHEARWALL LENGTHS ARE SPECIFIED ON THE PLANS, THE LENGTH SHOWN IS A <br />MINIMUM DIMENSION. THE SHEARWALL MAY BE LENGTHENED FOR CONSTRUCTION <br />PURPOSES, BUT SHALL NOT BE REDUCED UNLESS OTHERWISE NOTED. ALL ENGINEERED <br />WOOD PANEL SHEAR (PLYWOOD OR OSB) SHALL BE BLOCKED. <br />324. THE FOLLOWING HOLES IN SHEARWALLS ARE ALLOWED: <br />A) APPROXIMATELY SQUARE HOLES NOTCHED, PUNCHED, OR CUT THATARE LESS THAN <br />25 SQ. INCHES <br />B) APPROXIMATELY SQUARE HOLES CLEAN CUT OR BORED IN SHEARWALLS THATARE <br />LESS THAN 64 SQ. INCHES (ONE HOLE PER 4' OF SHEARWALL.) <br />C) APPROXIMATELY SQUARE HOLES, LESS THAN 64 SO. INCHES (ONE HOLE PER 8' OF <br />SHEARWALL) WITH ALL EDGES BLOCKED & EDGE NAILED. <br />D) HOLES INDIVIDUALLYAPPROVED BY THE ENGINEER OR ARCHITECT OF RECORD. <br />325. STUDS SHALL BE SPACED @ 16" O/C MAX. UNLESS OTHERWISE SPECIFIED. <br />EXCEPT AT PLATE HEIGHTS HIGHER THAN 10'-0", THEN USE DF#2 OR BETTER <br />326. ALL FINISHES, WATERPROOFING, DRAINAGE, AND FIRE -RELATED ELEMENTS ARE BY THE <br />ARCHITECT OF RECORD AND ARE REQUIRED EVEN THOUGH THEY MAY NOT BE SHOWN <br />ON THE STRUCTURAL PLANS AND DETAILS. <br />4. ICC-ES AND NER APPROVALS <br />400. PLYWOOD AND OSB PANELS: FULL REPORTS FOUND AT: <br />APA PLYWOOD & OSB--ESR-2586 HTTP://WWW.ICC-ES.ORG <br />401. JOISTS AND RAFTERS AND BEAMS: <br />TRUS-JOIST TJI JOISTS AND PSL, LSL, & LVL--ICC-ES ESR-1387, 1153, <br />BOISE CASCADE BCI JOISTS, VERSA -LAM, & VERSA-STRAND--ICC-ESR-1040, 1336 <br />LOUISIANA PACIFIC JOISTS & BEAMS--ESR-1305, 2403 <br />ROSEBURG JOISTS & BEAMS--ESR-1210, 1251 <br />GLU-LAM BEAMS-- ESR-1940 <br />PACIFIC WOOD TECH - ESR 2909 <br />402. WOOD CONNECTORS: <br />SIMPSON CONNECTORS--ICC-ES ESR #S 1161,1622, 1866, 2105, 2203, 2236, 2320, <br />2549, 2551, 2552, 2553, 2330, 2554, 2555, 2604, 2605, 2606, 2607, 2608, <br />2611, 2613, 2614, 2615, 2616, 2877, 2920, 3046 <br />IAPMO ER-112,130, 143, 192, 262 <br />USP LUMBER CONNECTORS--ICC-ES ESR #S 1178,1280, 1575, 1702, 1781, 1881, <br />1970 2104 2685 1831 146 2761 27 7 IAPMO ER-2 5, 8 , 00 <br />QUICK DRIVE WOOD SCREWS--ICC-ES ESR-1472 <br />403, ADHESIVES & ANCHORS: <br />SIMPSON EPDXY -TIE HIGH STRENGTH EPDXY (SET-XP)--ICC-ES ESR-1772, 2508. <br />SIMPSON WEDGE -ALL (WA) WEDGE ANCHORS--ICC-ES ES-1771 <br />SIMPSON TITEN HD--ICC-ESR-1056, 2713 <br />SIMPSON SHOT PINS ICC-ES ESR-2138 <br />HILTI X-DN, X-ZF, X-CF SHOT PINS--ICC-ES ER-1663, 1752, 2269 <br />5. NAILING & FASTENING <br />500.16D NAILS AS SHOWN ON THE DETAILS MAY BE COMMON, BOX, OR SINKER NAILS (0.135" MIN. DIA) <br />501. AS AN ALTERNATE TO THE COMMON AND BOX NAILS SPECIFIED IN THE STRUCTURAL PLANS, THE <br />FOLLOWING "CUTLER" GUN NAILS (OR EQUAL) ARE ACCEPTABLE ALTERNATIVES. <br />502. ALTERNATE NAILING FOR ROOF SHEATHING: <br />8D 2 2 " X 0.135 WIRE BARBED NAILS BY CUTLER OR EQUAL. <br />503. ALTERNATE NAILING FOR FLOOR SHEATHING: #8 X 2" SELF SETTING WOOD SCREWS, OR <br />8D 2 2 " X 0.135 OR 0.148 SCREW SHANK FLOOR NAILS BY CUTLER OR EQUAL <br />504. SHEAR PANELS WHERE 8D COMMON NAILS ARE SPECIFIED: <br />10D 2 z " X 0.148" WIRE BARBED NAILS BY CUTLER OR EQUAL <br />NAIL SIZES <br />SIZE OF STANDARD WIRE SIZE PENETRATION <br />NAIL LENGTH GAUGE (INCHES) REQUIRED <br />BOX NAILS <br />6D 2" 12 0.099 1 it <br />8D 2 " 11 0.113 ill <br />10D 3" 10- 0.128 10 " <br />12D 3" 10- 0.128 10 " <br />16D 3-11 10 0.135 1 0 It <br />16D SINKER 3" 9 0.148 1011 <br />COMMON NAILS <br />6 D 2" 11 - 0.113 1 " <br />8D 22 10 0.131 1 7" 10D 3„ 9 0.148 1 a <br />12D 3„ 9 0.148 1 a <br />16D 3 8 0.162 1„ <br />12 <br />6. NAILING SCHEDULE, MINIMUMS (CBC CHAPTER 23, TABLE 2304.10.2) <br />BLKNG AT CEILING JOISTS, RAFTERS, OR TRUSSES TO TOP PLATE OR OTHER FRAMING, <br />T.N. 4-8d Box, 3-8d Com, 3-10d box, 3-3" x 0.131" nails, 3-3" 14 gage staples <br />BLKNG AT CEILING RAFTERS OR TRUSSES NOT AT WALL TOP PLATE TO RAFTER OR TRUSS, T.N. 2-8d Com, 2-3" x 0.131" nails, 2-3" 14 gage staples <br />BLKNG AT CEILING RAFTERS OR TRUSSES NOT AT WALL TOP PLATE TO RAFTER OR TRUSS, E.N. 2-16d Com, 3-3" x 0.131" nails, 3-3" 14 gage staples <br />FLAT BLKNG TO TRUSS AND WEB, F.N. <br />16d Com, 3"x.131" nails, 3"x14 gage staples @ 6" o.c <br />CEILING JOISTS TO TOP PLATE, T.N. <br />4-8d box, 3-8d Com, 3-10d box, 3-3"x.131 nails, 3-3" 14 gage staples <br />CEILING JOISTS NOT ATTACHED TO PARALLEL RAFTER, LAPS OVER PARTITIONS, F.N. <br />PER 2308.7.3.1 3-16d Com, 4-10d box, 4-3" x 0.131" nails, 4-3" 14 gage staples <br />CEILING JOISTS ATTACHED TO PARALLEL RAFTER (HEEL JOINT), F.N. PER 2308.7.3.1 <br />3-16d Com, 4-10d box, 4-3" x 0.131" nails, 4-3" 14 gage staples <br />COLLAR TIE TO RAFTER, F.N. <br />3-10d Com, 4-10d box, 4-3"x0.131" nails, 4-3" 14 gage staples <br />RAFTER/TRUSS TO TOP PLATE, T.N. PER TABLE 2308.7.3.5 <br />3-10d Com, 3-16d or 4-10d box, 4-3" x 0.131" nails, 4-3" 14 gage staples <br />RAFTERS TO RIDGE VALLEY OR HIP; OR FATERTO 2" RIDGE BEAM <br />TOENAIL <br />4-16d box, 3-10d Com, 3-16d or 4-10d box, 4-3" x 0.131" nails, 4-3" 14 gage staples <br />ENDNAIL <br />2-16d Com, 3-16d box, 3-10d box, 3-3" x 0.131" nails, 3-3" 14 gage staples <br />STUD TO STUD (NOT AT BRACED WALL PANELS) <br />16d Com @ 24" o.c. FN OR 2-10d box, 3" x 0.131" nails, 34' 14 gage staples @ 16" o.c. FN <br />STUD TO STUD AT INTERSECTING WALL CORNERS (BRACED WALL) <br />16d Com @ 16" o.c, FN OR 16d Box, 3" x 0.131" nails, 3-3" 14 gage staples @ 12" o.c. FN <br />BUILT-UP HEADER (2" TO 2"), FN EA. EDGE <br />16d Com @ 16" o.c OR 16d Box @ 12" o.c. <br />CONT. HEADER TO STUD, T.N. <br />4-8d Com, 4-10d Box, 5-8d box <br />TOP PLATE TO TOP PLATE <br />16d Com @ 16" o.c. FN OR 10d Box, 3" x 0.131" nails, 3" 14 gage staples @ 12 o.c. FN <br />TOP PLATE TO TOP PLATE, AT END JOINTS (EACH SIDE OF END JOINT), FACENAIL <br />24" MIN LAP SPLICE EA. SIDE <br />8-16d Com, 12-16d Box, 12-10d Box, 12-3" x 0.131" nails, 12-3" 14 gage staples <br />BOTTOM PLATE TO JOIST, RIM, OR BLKG, FACENAIL <br />UNBRACED WALL: 16" o.c. FN <br />16d Com <br />UNBRACED WALL: 12" o.c. FN <br />16d Box, 3" x 0.131" nails, 3" 14 gage staples <br />BRACED WALL: 16"o.c. FN <br />2-16d Com, 3-16d Box,44'031" nails,4-3" 14 gage staples <br />STUD TO TOP OR BOTTOM PLATE <br />TOENAIL <br />4-8d Box, 410d Box, 4-8d Com, 3-16d Box, 44' 0.131" nails, 4-3" 14 gage staples <br />ENDNAIL <br />3-16d Box, 2-16d Com, 3-10d Box, 344,131" nails, 3-3" 14 gage staples <br />TOP PLATES, LAPS AT CORNERS AND INTERSECTION, F.N. <br />2-16d Com, 3-1 Old box, 3-3" x 0.131" nails, 3-3" 14 gage staples <br />1" BRACE TO EACH STUD AND PLATE, F.N. <br />3-8d Box, 2-8d Com, 2-10d Box, 2-3" x 0.131" nails, 2-3" 14 gage staples <br />1"x6" SHEATHING TO EACH BEARING, F.N. <br />3-8d Box, 2-1.75" 16 Gage staples, 2-8d Com, 2-1 Old Box <br />1"x8" SHEATHING AND WIDER TO EACH BEARING, F.N. <br />4-8d box, 4-1.75" 16 Gage staples, 3-8d Com, 3-10d Box <br />JOIST TO SILL, TOP PLATE, OR GIRDER, T.N. <br />4-8d box, 3-8d Com, 3-10d Box, 3-3" x 0.131" nails, 3-3" 14 gage staples <br />RIM JOIST, BAND JOIST, OR BLOCKING TO TOP PLATE, SILL OR OTHER 8d Box @ 4" o.c. TN OR 8d Com, 10d Box, 3" x 0.131" nails, 3" 14 gage staples @ 6" o.c. TN <br />1"x6" SUBFLOOR OR LESS TO EACH JOIST, F.N. <br />2-1.75" Gage Staples, 2-8d Com, 3-10d Box <br />2" SUBFLOOR TO JOIST OR GIRDER, F.N. or BLIND <br />3-16d Box, 2-16d Com <br />2" PLANKS (PLANK & BEAM - FLOOR & ROOF), FACENAIL & EACH BEARING <br />3-16d Box, 2-16d Com <br />BUILT-UP GIRDERS AND BEAMS, 2" LUMBER LAYERS <br />32" o.c. FN Top & BTTM STAGGERED ON OPPOSITE SIDES <br />20d Com <br />24" o.c. FN Top & BTTM <br />10d Box, 3"x0.131" nails, 3" 14 gage staples <br />ENDS & SPLICES, FN <br />2-20d Com, 3-1 Old Box, 34' 0.131" nails, 3-3" 14 gage staples <br />LEDGER SUPPORTING JOISTS/RAFTERS <br />4-16d Box, 3-16d Com, 4-10d Box, 4-3"X0.131, 4-3" 14ga. STAPLES <br />JOIST TO BAND OR RIM JOIST, END NAIL <br />3-16d Com, 4-10d Box, 4-3"X0.131, 4-3" 14ga. STAPLES <br />BRIDGING OR BLOCKING TO JOIST, RAFTER OR TRUSS EACH END, T.N. <br />2-8d Com, 2-10d box, 2-3" x 0.131" nails, 2-3" 14 gage staples <br />WOOD STRUCT. PANELS, SUBFLOOR, ROOF AND INTERIOR WALL SHTNG TO FRMG AND <br />EDGES <br />INTERMEDIATE <br />PARTICLEBOARD WALL SHEATHING TO FRAMING <br />(IN) <br />SUPPORTS (IN) <br />16d Com or deformed; or 22"x.113" nail (subfloor aid wall) <br />6 <br />12 <br />8d Com or deformed (roof) or 28" x.113" nail (roof) <br />6e <br />6e <br />"-2" <br />14" 16 Ga Staple, ' crown (subfloor and wall) <br />4 <br />8 <br />22" x.113"x.266" head nail (roof) <br />3 f <br />3 f <br />14" 16 Ga Staple,6"crown (roof) <br />3f <br />3f <br />8d Com or deformed (subfloor and wall) <br />6 <br />12 <br />19,, 31, <br />32 —4 <br />8d Com or deformed (roof) or 28" x.113" nail (roof) <br />6e <br />6e <br />28" x.113"x.266" head nail, 2"16 Gage staple, 6' crown <br />4 <br />8 <br />8 -14 <br />�10cl Com or (T4.148"); or deformed (271 x.131 "x.281 head) <br />6 <br />12 <br />OTHER EXTERIOR <br />WALL SHEATHING (FIBERBOARD) <br />1„b <br />12" x0.120", galvanized roofing nail (16" head dia) or 14" 16 Ga Staple w/6" or 1" crown <br />3 <br />6 <br />2 <br />25,1 <br />13" x0,120", galvanized roofing nail (16" head dia) or 12" 16 Ga Staple w/ 6" or 1" crown <br />3 <br />6 <br />WOOD STRUCTURAL PANELS, COMBINATION SUBFLOOR UNDERLAYMENTTO FRAMING <br />4 & LESS <br />8d COMMON (2 2 x0.131 ), or deformed (2 x0.113 ), or deformed (2 x0.120) <br />6 <br />12 <br />a" 1" <br />8d COMMON (2 z"x0.131 "); or deformed (2"x0.113" ); or deformed (2"0.120") <br />6 <br />12 <br />11" -11" <br />10d COMMON (3"x0.148"); or deformed (22"x0.131 "); or deformed (22"x0.120") <br />6 <br />12 <br />PANEL SIDING TO FRAMING <br />2" & LESS <br />6d corrosion -resistant siding (18"x.106"); or 6d corrosion -resistant (2"x.099") <br />6 <br />12 <br />g" <br />8d corrosion -resistant siding (28"0.128"); or 8d corrosion -resistant casing (22"x0.113") <br />6 <br />12 <br />INTERIOR PANELING <br />-'4" <br />4d casing (12"x0.080"); or 4d finish (12"x0.072") <br />6 <br />12 <br />8„ <br />6d casing (2'4.099"); or 6d finish (2"x.092") - (Panel supports at 24 inches) <br />6 <br />12 <br />7. DESIGN CRITERIA <br />700, BUILDING CODE: 2022 CALIFORNIA BUILDING CODE AND 2022 CALIFORNIA <br />RESIDENTIAL CODE. <br />701. SEISMIC DESIGN CRITERIA: <br />SOIL BEARING VALUE <br />1,500 psf <br />SITE CLASS <br />D (Default) <br />SEISMIC DESIGN CATEGORY <br />D <br />RISK CATEGORY <br />II <br />SEISMIC IMPORTANCE FACTOR <br />1 <br />SS <br />1.50 <br />S1 <br />0.50 <br />SIDS <br />1.20 <br />SD1 <br />0.60 <br />Cs <br />0.185 <br />Design Base Shear <br />0.168W <br />702. WIND DESIGN CRITERIA: <br />WIND SPEED (V-ult) <br />124 mph <br />RISK CATEGORY <br />II <br />EXPOSURE <br />C <br />INTERNAL PRESSURE COEF <br />0.18 <br />EXTERIOR CLADDING (0.6W) <br />13 psf <br />703. DESIGN LOADING (Worst Case): <br />ROOF DL 14 psf I <br />ROOF LL 20 psf <br />TRELLIS DL 8 psf I <br />TRELLIS ILL 10 psf <br />FOOTNOTES: <br />a. Nails spaced at 6 inches at intermediate supports where spans are <br />48 inches or more. For nailing of wood structural panel and <br />particleboard diaphragms and shear walls, refer to Section 2305. Nails <br />for wall sheathing are permitted to be common, box or casing. <br />b. Spacing shall be 6 inches on center on the edges and 12 inches on <br />center at intermediate supports for nonstructural applications. Panel <br />supports at 16 inches (20 inches if strength axis in the long direction of <br />the panel, unless otherwise marked). <br />c. Where a rafter is fastened to an adjacent parallel ceiling joist in <br />accordance with this schedule and the ceiling joist is fastened to the top <br />plate in accordance with this schedule, the number of toenails in the <br />rafter shall be permitted to be reduced by one nail. <br />d. RSRS-01 is a Roof Sheathing Ring Shank nail meeting the <br />specifications in ASTM F1667. e <br />e. Tabulated fastener requirements apply where the ultimate design <br />wind speed is less than 140 mph. For wood structural panel roof <br />sheathing attach tgable-endr fr in n e ed o roof am and to intermediate <br />9 9 <br />supports within 48 inches of roof edges and ridges, nails shall be <br />spaced at 4 inches on center where the ultimate design wind speed is <br />greater than 130 mph in Exposure B or greater than 110 mph in <br />Exposure C. Spacing exceeding 6 inches on center at intermediate <br />supports shall be permitted where the fastening is designed per the <br />AWC NDS. <br />e. Fastening is only permitted where the ultimate design wind speed is <br />less than or equal to 110 mph <br />g. Nails and staples are carbon steel meeting the specifications of <br />ASTM F1667. Connections using nails and staples of other materials, <br />such as stainless steel, shall be designed by acceptable engineering <br />practice or approved under Section 104.11, <br />8. STATEMENT OF SPECIAL INSPECTIONS <br />800. RETROFIT ANCHOR BOLTS FOR MISPLACED HOLDOWNS WITH <br />ALL -THREAD ROD AND SIMPSON SET-XP EPDXY REQUIRE <br />SPECIAL INSPECTION. (NO SPECIAL INSPECTION IS REQUIRED <br />FOR RETROFIT ANCHOR BOLTS OR TITEN HD's WITHOUT A <br />HOLDOWN ATTACHED,) <br />801. PER CBC 1705.3 SPECIAL INSPECTION IS NOT REQUIRED FOR <br />NON-STRUCTURAL SLABS ON GRADE NOR FOR CONCRETE <br />FOOTINGS THAT SUPPORT 3 STORIES ABOVE GRADE OR LESS. <br />802. PER CBC 1705.11 SPECIAL INSPECTION IS NOT REQUIRED FOR <br />SEISMIC COMPONENTS FOR DETTACHED ONE- AND <br />TWO-FAMILY DWELLINGS NOT EXCEEDING 2 STORIES ABOVE <br />GRADE. <br />19. SOILS REPORT 1 <br />A SOIL REPORT IS REQUIRED FOR PROPOSED DETACHED ADU WITH BUILDING <br />AREA EXCEEDING 750 sq.ft. THE GEOTECHNICAL INVESTIGATIONS SHALL BE <br />CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND REPORTED IN <br />ACCORDANCE WITH SECTION 18.3.6, CBC. <br />i. THE GEOTECHNICAL ENGINEER OF RECORD SHALL REVIEW THE CITY <br />APPROVED PLANS FOR GENERAL CONFORMANCE WITH THE SOIL REPORT; <br />OTHERWISE, AN ALTERNATE FOUNDATION PLAN DESIGNED BY A CALIFORNIA <br />REGISTERED CIVIL ENGINEER IS REQUIRED. <br />41055 CHACO CANYON ROAD <br />MURRIETA CA 92562 <br />All ideas, drawings, specifications shown herein are the <br />property of West Coast Design Group and shall not be <br />used, copied, reproduced, or disclosed to any person, firm <br />or corporation, without the written consent of West Coast <br />Design Group. Any infringement will be subject to legal <br />action. The contractor shall verify and be responsible for all <br />dimensions and conditions on the job and notify this office of <br />any variations from dimensions and conditions shown <br />herewith. Written dimensions take precedence over scaled <br />dimensions. <br />PROJECT: <br />ADU <br />3110 & 3112 S Griset PI <br />Santa Ana, CA 92704 <br />CLIENT: <br />Matthew Mallari & <br />Natalie Nguyen <br />Q 0 <br />I v ( No. 38 M <br />LLJ <br />1 # Exp� _ y <br />� l <br />r / <br />Mark Transrflittal,S"et•D8te'` Description <br />01 12/1012__E " <br />03 3/27/9025 <br />Plat FiIN�s Li HAS REVt€.VVI:D i. t5r- <br />r O MEMBER SIZES AND <br />CONi EC-ii1GNS AS REFLECTED <br />DIMENSIONS AND <br />sav v S �t't1CTtlRAL ITOAS ARE HE <br />PROJECT NO: 52-24 <br />STATUS: Submittal <br />DRAWN BY: <br />CHK'D BY: <br />PLOT DATE: 4/18/2025 <br />PLAN CHECK#: 101122356 <br />SHEET TITLE <br />Notes <br />S-0 <br />SHEET 26 <br />