Laserfiche WebLink
All ideas, drawings,specifications shown herein are the <br />property of West Coast Design Group and shall not be <br />used, copied, reproduced, or disclosed to any person, firm <br />or corporation, without the written consent of West Coast <br />Design Group. Any infringement will be subject to legal <br />action. The contractor shall verify and be responsible for all <br />dimensions and conditions on the job and notify this office of <br />any variations from dimensions and conditions shown <br />herewith. Written dimensions take precedence over scaled <br />dimensions. <br />Mark Transmittal Set Date Description <br />01 12/19/2024 <br />SHEET TITLE <br />A-2 <br />SHEET 13 <br />PROJECT NO: <br />STATUS: <br />DRAWN BY: <br />CHK'D BY: <br /> <br /> <br />PROJECT: <br />CLIENT: <br />PLOT DATE: 3/14/2025 <br /> 52-24 <br />PLAN CHECK#:101122356 <br /> C <br />: <br />\ <br />U <br />s <br />e <br />r <br />s <br />\ <br />j <br />e <br />r <br />r <br />y <br />\ <br />D <br />o <br />c <br />u <br />m <br />e <br />n <br />t <br />s <br />\ <br />D <br />r <br />a <br />w <br />i <br />n <br />g <br />s <br />\ <br />R <br />e <br />s <br />i <br />d <br />e <br />n <br />t <br />i <br />a <br />l <br />\ <br />S <br />a <br />n <br />t <br />a <br /> <br />An <br />a <br /> <br />Gr <br />i <br />s <br />e <br />t <br /> <br />PI <br />\ <br />C <br />D <br />\ <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />G <br />r <br />i <br />s <br />e <br />t <br /> <br />P <br />I <br />. <br />p <br />l <br />n <br /> Submittal <br /> <br />Reflected Ceiling Plan/ Power <br />Plan <br />ADU <br />3110 & 3112 S Griset Pl <br />Santa Ana, CA 92704 <br />Matthew Mallari & <br />Natalie Nguyen <br />PLANNING - DESIGN <br />41055 CHACO CANYON ROAD <br />MURRIETA CA 92562 <br />WEST COAST <br />DESIGN GROUP <br />Reflected Ceiling <br />2D Symbol <br />CM <br />SD <br />VS <br />Dim <br />Name <br />Bathroom <br />Exhaust Fan <br />Can Light <br />Carbon <br />Monoxide <br />Detector <br />Exterior Light <br />fixture <br />Kitchen Vent <br />Exhaust Fan <br />Laundry room <br />exhaust fan. <br />Light Switch <br />Smoke <br />Detector <br />Switch - <br />Vacancy <br />Sensor <br />Switch- <br />Dimmer <br />Description <br />Exhaust fan- a min. of 5 air exchanges per hour. and <br />shall be exhausted to the exterior. 50 cfm. min. and <br />humidistat control in bathrooms with tub, shower or <br />tub/shower. the exhaust fan shall be certified and listed <br />on the california energy commission appliance <br />database. fan shall be on a separate switch than the <br />light fixture. <br />6" dia. Led light fixture. Install in ceiling per manuf. <br />Fixture to be ic rated for installation with insulation <br />CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR <br />PRIMARY POWER FROM THE BUILDING WIRING AND <br />SHALL HAVE BATTERY BACKUP <br />Wall mounted - owner to select. See notes this sheet for <br />additional information. Mount between 65"-67" above <br />grade <br />Stove Fan shall have a Min. OF 100 CFM * vent to the <br />outside air <br />Fan must exhaust a min. 50 CFM and be separately <br />switched from the lighting. <br />Light switch mounted 48" A.F.F. Adjust location at <br />counters, islands, etc. <br />SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY <br />POWER FROM THE BUILDING WIRING AND SHALL <br />HAVE BATTERY BACKUP. <br />Switch vacancy sensor control <br />Light switch with dimming capabilities that meet <br />current code. Typical height to be 48" to the bottom of <br />the switch A.F.F. Adjust height as required for counters, <br />island, etc. <br />Quantity <br />1 <br />15 <br />2 <br />1 <br />1 <br />1 <br />2 <br />4 <br />1 <br />4 <br />F <br />Di <br />m <br />VS <br />Di <br />m <br />Dim <br />Dim <br />CM <br />SD <br />SD <br />SD <br />CM <br />SD <br />LIVING ROOM <br />BATH <br />BEDROOM <br />BEDROOM <br />KITCHEN <br />24"x30" <br />ATTIC <br />ACCESS <br />PROVIDE <br />POWER FOR <br />HOOD VENT <br />PROVIDE A <br />WHOLE HOUSE <br />FAN WITH 1500 <br />CFM VENTED TO <br />OUTSIDE AIR <br />F <br />GFCI <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GFCI <br />AFCI <br />AF <br />C <br />I <br />AFCI <br />AFCI <br />AF <br />C <br />I <br />AFCI <br />AF <br />C <br />I <br />AFCI <br />WP <br />G <br />F <br />C <br />I <br />WP <br />G <br />F <br />C <br />I <br />J <br />GFCI <br />5 <br />A-6 <br />LIVING ROOM <br />BATH <br />BEDROOM <br />BEDROOM <br />KITCHEN <br />POWER FOR <br />GARBAGE <br />DISPOSAL <br />PROVIDE <br />POWER FOR <br />HOOD VENT <br />(N) 150A <br />ELECTRICAL <br />PANEL <br />GF <br />C <br />I <br />Power Legend <br />Symbol <br />GFCI <br />J <br />AFCI <br />WPGFCI <br />Name <br />Ground Fault Circuit <br />Interrupter <br />Junction Box <br />Outlet - AFCI <br />Water Proof Ground <br />Fault Circuit <br />Interrupter <br />Description <br />GFCI - 12" - 18" A.F.F. to center of outlet U.N.O. 6" <br />above counter services, typ. <br />Junction box for the hood power. Very req. with <br />manufacturer <br />Arc fault circuit interrupter - 12" - 18" A.F.F. to center <br />of outlet U.N.O. 6" above counter services, typ. <br />An exterior GFCI with a cover per latest code. <br />Quantity <br />7 <br />1 <br />8 <br />2 <br />Type of Appliance Branch Circuit Rating <br />Electrical range (240V)50 amperes <br />Kitchen counter top small appliance branch circuit (120V)20 amperes <br />Counter-mounted electric cooking unit (240V)30 amperes <br />Dishwasher (120V)15 -20 amperes <br />Garbage Disposal (120V)15 amperes <br />Wall -mounted electric oven (240V)30 -40 amperes <br />Microwave (120V)20 amperes <br />Trash Compactor (120V)15 amperes <br />Separate Circuit required for each of the above appliances <br />SCALE: 1/4" = 1'-0"1 Reflected Ceiling Plan <br />SCALE: 1/4" = 1'-0"2 Power Plan <br /> OUTDOOR LIGHTING REQUIREMENTS <br />1. OUTDOOR LUMINAIRES <br />ALL LIGHTING ATTACHED TO THE RESIDENCE OR TO OTHER <br />BUILDINGS ON THE SAME LOT MUST BE HIGH EFFICACY. TABLE <br />150.0-A LISTS ALL QUALIFYING HIGH EFFICACY LIGHT SOURCES. <br />NOTE THAT SOLID STATE LIGHTING (SSL) LUMINAIRES INSTALLED <br />OUTDOORS ARE EXEMPTED FROM THE GENERAL RESIDENTIAL <br />LIGHTING REQUIREMENT THAT ALL SSL LUMINAIRES FOR <br />RESIDENTIAL LIGHTING MUST MEET THE REQUIREMENTS OF JOINT <br />APPENDIX JA8. <br />2. SINGLE-FAMILY OUTDOOR LIGHTING <br />ALL LIGHTING ATTACHED TO THE RESIDENCE OR TO OTHER <br />BUILDINGS ON THE SAME LOT MUST BE HIGH EFFICACY, AND MUST <br />BE CONTROLLED BY A MANUAL ON AND OFF SWITCH AND ONE OF <br />THE FOLLOWING AUTOMATIC CONTROL TYPES: <br /> A. PHOTOCONTROL AND MOTION SENSOR. <br /> B. PHOTOCONTROL AND AUTOMATIC TIME SWITCH CONTROL. <br /> C. ASTRONOMICAL TIME CLOCK CONTROL THAT AUTOMATICALLY <br />TURNS THE OUTDOOR LIGHTING OFF DURING DAYLIGHT HOURS. <br />3. EMCS THAT PROVIDES THE FUNCTIONALITY OF AN <br />ASTRONOMICAL TIME CLOCK, DOES NOT HAVE AN OVERRIDE OR <br />BYPASS SWITCH THAT ALLOWS THE LUMINAIRE TO BE ALWAYS ON, <br />AND IS PROGRAMMED TO AUTOMATICALLY TURN THE OUTDOOR <br />LIGHTING OFF DURING DAYLIGHT HOURS. <br />MANUAL ON AND OFF SWITCHES MUST NOT OVERRIDE THE <br />AUTOMATIC CONTROL FUNCTIONS LISTED ABOVE, AND ANY <br />CONTROL THAT OVERRIDES THE AUTOMATIC CONTROLS TO ON <br />MUST AUTOMATICALLY REACTIVATE THOSE CONTROLS WITHIN SIX <br />HOURS. <br />LIGHTING THAT IS NOT PERMANENTLY ATTACHED TO A BUILDING <br />ON A SINGLE-FAMILY SITE, SUCH AS DECORATIVE LANDSCAPE <br />LIGHTING, IS NOT REGULATED BY THE RESIDENTIAL LIGHTING <br />REQUIREMENTS. HOWEVER, PROVIDING HIGH EFFICACY LIGHTING <br />AND CONTROLS SUCH AS A TIME CLOCK OR PHOTOCONTROL WILL <br />HELP SAVE ENERGY AND ENSURE THAT THE LIGHTING IS NOT <br />ACCIDENTALLY LEFT ON DURING DAYLIGHT HOURS. <br />LUMINAIRE REQUIREMENTS <br /> RECESSED DOWNLIGHT LUMINAIRES IN CEILINGS. <br />LUMINAIRES RECESSED INTO CEILINGS SHALL MEET ALL OF THE <br />FOLLOWING REQUIREMENTS: <br />I. BE LISTED, AS DEFINED IN SECTION 100.1, FOR ZERO <br />CLEARANCE INSULATION CONTACT (IC) BY UNDERWRITERS <br />LABORATORIES OR OTHER NATIONALLY RECOGNIZED <br />TESTING/RATING LABORATORY; AND <br />II. HAVE A LABEL THAT CERTIFIES THE LUMINAIRE IS AIRTIGHT <br />WITH AIR LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS WHEN <br />TESTED IN ACCORDANCE WITH ASTM E283. AN EXHAUST FAN <br />HOUSING SHALL NOT BE REQUIRED TO BE CERTIFIED AIRTIGHT; <br />AND <br />III. BE SEALED WITH A GASKET OR CAULK BETWEEN THE <br />LUMINAIRE HOUSING AND CEILING, AND SHALL HAVE ALL AIR LEAK <br />PATHS BETWEEN CONDITIONED AND UNCONDITIONED SPACES <br />SEALED WITH A GASKET OR CAULK; AND <br />IV. FOR LUMINAIRES WITH HARDWIRED BALLASTS OR DRIVERS, <br />ALLOW BALLAST OR DRIVER MAINTENANCE AND REPLACEMENT TO <br />BE READILY ACCESSIBLE TO BUILDING OCCUPANTS FROM BELOW <br />THE CEILING WITHOUT REQUIRING THE CUTTING OF HOLES IN THE <br />CEILING; AND <br />V. SHALL NOT CONTAIN SCREW BASE SOCKETS; AND <br />VI. SHALL CONTAIN LIGHT SOURCES THAT COMPLY WITH <br />REFERENCES JOINT APPENDIX JA8, INCLUDING THE ELEVATED <br />TEMPERATURE REQUIREMENTS, AND THAT ARE MARKED “JA8-2016- <br />E” AS SPECIFIED IN REFERENCE JOINT APPENDIX JA8. <br />2. LIGHTING INTEGRAL TO EXHAUST FANS SHALL MEET THE <br />APPLICABLE REQUIREMENTS OF SECTION 150.0(K). <br /> EXCEPTION TO SECTION 150.0(K)1F: LIGHTING INSTALLED BY THE <br />MANUFACTURER IN KITCHEN EXHAUST HOODS. <br />SCREW BASED LUMINAIRES SHALL MEET ALL OF THE FOLLOWING <br />REQUIREMENTS: <br />I. THE LUMINAIRES SHALL NOT BE RECESSED DOWNLIGHT <br />LUMINAIRES IN CEILINGS; AND <br />II. THE LUMINAIRES SHALL CONTAIN LAMPS THAT COMPLY WITH <br />REFERENCE JOINT APPENDIX JA8; AND <br />III. THE INSTALLED LAMPS SHALL BE MARKED WITH “JA8-2016” <br />OR “JA8-2016-E” AS SPECIFIED IN REFERENCE JOINT APPENDIX <br />JA8. <br />EXCEPTION TO SECTION 150.0(K)1G: LUMINAIRES WITH HARD- <br />WIRED BALLASTS FOR HIGH INTENSITY DISCHARGE LAMPS. <br />H. ENCLOSED LUMINAIRES. LIGHT SOURCES THAT ARE NOT <br />MARKED “JA8-2016-E” SHALL NOT BE INSTALLED IN ENCLOSED <br />LUMINAIRES. <br />INTERIOR LIGHTING SWITCHING DEVICES AND <br />CONTROLS. <br />A. ALL FORWARD PHASE CUT DIMMERS USED WITH LED LIGHT <br />SOURCES SHALL COMPLY WITH NEMA SSL 7A. <br />B. EXHAUST FANS SHALL BE SWITCHED SEPARATELY FROM <br />LIGHTING SYSTEMS. <br />EXCEPTION TO SECTION 150.0(K)2B: LIGHTING INTEGRAL TO AN <br />EXHAUST FAN MAY BE ON THE SAME SWITCH AS THE FAN <br />PROVIDED THE LIGHTING CAN BE SWITCHED OFF IN ACCORDANCE <br />WITH THE APPLICABLE PROVISIONS IN SECTION 150.0(K)2 WHILE <br />ALLOWING THE FAN TO CONTINUE TO OPERATE FOR AN EXTENDED <br />PERIOD OF TIME. <br />C. LUMINAIRES SHALL BE SWITCHED WITH READILY ACCESSIBLE <br />CONTROLS THAT PERMIT THE LUMINAIRES TO BE MANUALLY <br />SWITCHED ON AND OFF. <br />D. LIGHTING CONTROLS AND EQUIPMENT SHALL BE INSTALLED IN <br />ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br /> NOTES: <br />1. SMOKE ALARMS SHALL BE HARDWIRED WITH BATTERY BACKUP <br />AND INTERCONNECTED SO THAT THE ACTIVATION OF ONE ALARM <br />SHALL ACTIVATE ALL OTHER ALARMS IN THE DWELLING UNIT. <br />RETROFIT ALARMS MAY BE BATTERY OPERATED IN ROOMS WHERE <br />CONSTRUCTION IS NOT PROPOSED. <br />2. CARBON MONOXIDE ALARMS SHALL BE HARDWIRED WITH <br />BATTERY BACKUP AND INTERCONNETED SO THAT THE ACTIVATION <br />OF ONE ALARM SHALL ACTIVATE ALL OTHER ALARMS IN THE <br />DWELLING UNIT. RETROFIT ALARMS MAY BE BATTERY OPERATED IN <br />ROOMS WHERE ALTERATIONS/REPAIRS DO NOT RESULT IN THE <br />REMOVAL OF WALS OR CEILING FINISHES. <br />E. NO CONTROLS SHALL BYPASS A DIMMER OR VACANCY SENSOR <br />FUNCTION WHERE THAT DIMMER OR VACANCY SENSOR HAS BEEN <br />INSTALLED TO COMPLY WITH SECTION 150.0(K). <br />F. LIGHTING CONTROLS SHALL COMPLY WITH THE APPLICABLE <br />REQUIREMENTS OF SECTION 110.9. <br />G. AN ENERGY MANAGEMENT CONTROL SYSTEM (EMCS) MAY BE <br />USED TO COMPLY WITH DIMMER REQUIREMENTS IN SECTION 150.0 <br />(K) IF AT A MINIMUM IT PROVIDES THE FUNCTIONALITY OF A <br />DIMMER IN ACCORDANCE WITH SECTION 110.9, MEETS THE <br />INSTALLATION CERTIFICATE REQUIREMENTS IN SECTION 130.4, <br />THE EMCS REQUIREMENTS IN SECTION 130.5(F), AND COMPLIES <br />WITH ALL OTHER APPLICABLE REQUIREMENTS IN SECTION 150.0(K) <br />2. <br />H. AN ENERGY MANAGEMENT CONTROL SYSTEM (EMCS) MAY BE <br />USED TO COMPLY WITH VACANCY SENSOR REQUIREMENTS IN <br />SECTION 150.0(K) IF AT A MINIMUM IT PROVIDES THE <br />FUNCTIONALITY OF A VACANCY SENSOR IN ACCORDANCE WITH <br />SECTION 110.9, MEETS THE INSTALLATION CERTIFICATE <br />REQUIREMENTS IN SECTION 130.4, THE EMCS REQUIREMENTS IN <br />SECTION 130.5(F) AND COMPLIES WITH ALL OTHER APPLICABLE <br />REQUIREMENTS IN SECTION 150.0(K)2. <br />I. A MULTISCENE PROGRAMMABLE CONTROLLER MAY BE USED TO <br />COMPLY WITH DIMMER REQUIREMENTS IN SECTION 150.0(K) IF AT <br />A MINIMUM IT PROVIDES THE FUNCTIONALITY OF A DIMMER IN <br />ACCORDANCE WITH SECTION 110.9, AND COMPLIES WITH ALL <br />OTHER APPLICABLE REQUIREMENTS IN SECTION 150.0(K)2. <br />J. IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY <br />ROOMS, AT LEAST ONE LUMINAIRE IN EACH OF THESE SPACES <br />SHALL BE CONTROLLED BY A VACANCY SENSOR. <br />K. DIMMERS OR VACANCY SENSORS SHALL CONTROL ALL <br />LUMINAIRES REQUIRED TO HAVE LIGHT SOURCES COMPLIANT <br />WITH REFERENCE JOINT APPENDIX JA8. <br />EXCEPTION 1 TO SECTION 150.0(K)2K: LUMINAIRES IN CLOSETS <br />LESS THAN 70 SQUARE FEET. <br />EXCEPTION 2 TO SECTION 150.0(K)2K: LUMINAIRES IN HALLWAYS. <br />L. UNDERCABINET LIGHTING SHALL BE SWITCHED SEPARATELY <br />FROM OTHER LIGHTING SYSTEMS. <br />ELECTRICAL NOTES: <br />1. A CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF <br />EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF <br />THE BEDROOM. <br />2. IN ALL AREAS SPECIFIED IN SECTION 210.52 OF THE CEC, ALL <br />125-VOLT, 15- AND 20- AMPERE CIRCUITS (INLUDING LIGHTING) <br />SHALL BE LISTED TAMPER-RESISTANT RECEPTACLE. <br />3. ALL NEW 15 & 20 AMP 120V RECEPTACLES TO BE AFCI <br />PROTECTED. <br />4. ELECTRICAL BOXES IN GARAGE SEPARATION WALLS AND <br />CEILING SHALL BE A METAL OR 1-HR. PLASTIC. <br />5. ALL ELECTRICAL OUTLETS SHALL BE TAMPER RESISTANT PER <br />SECTION 406.11 CEC. <br />6. ALL CIRCUITS SUPPLYING OUTLETS IN DWELLING UNIT FAMILY <br />ROOMS, DINING ROOMS,LIVING ROOMS, PARLORS, LIBRARIES, <br />DENS, BEDROOMS,SUNROOMS, RECREATION ROOMS, CLOSETS, <br />HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED <br />BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER COMBINATION TYPE <br />LISTED TO PROVIDE PROTECTION OF THE ENTIRE BRANCH CIRCUIT. <br />(LIGHTS, RECEPTACLES, FANS, SMOKE ALARMS, ETC.) <br />7. LAUNDRY AREA OUTLETS SHALL BE FED BY A DEDICATED 20A <br />CIRCUIT WITH NO OTHER OUTLETS. <br />8. WHEN MULTIPLE NEW HARD-WIRED SMOKE DETECTORS ARE <br />INSTALLED, THEY SHALL BE INTERCONNECTED (INTERLOCKED) SO <br />THAT WHEN ONE IS ACTIVATED THEY WILL ALL BE ACTIVATED. <br />9. IF MULTIPLE HARD-WIRED CARBON MONOXIDE ALARMS ARE <br />INSTALLED, THEY SHALL BE INTERCONNECTED SO THAT WHEN ONE <br />IS ACTIVATED THEY WILL ALL BE ACTIVATED. <br />10. A MINIMUM OF (1) 20 AMP CIRCUIT FOR BATHROOM(S) OUTLET. <br />SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. THE CIRCUIT MAY <br />SERVE MORE THAN ONE BATHROOM. <br />11. PROVIDE A MIN. OF 2-20 AMP SMALL APPLIANCE CIRCUITS FOR <br />THE KITCHEN COUNTER TOPS. SUCH CIRCUIT SHALL HAVE NO OTHER <br />OUTLET. LOAD SHALL BE BALANCED. CEC 210-52(B)(2).