My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2701 S Poplar St - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Poplar St
>
2701 S Poplar St
>
2701 S Poplar St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2025 12:44:29 PM
Creation date
6/15/2025 12:43:55 PM
Metadata
Fields
Template:
Plan
Permit Number
20184913
101122234
Full Address
2701 S Poplar St
Stamp
ID:
1
Creator:
Import Agent
Created:
6/15/2025 12:44 PM
Modified:
6/10/2025 12:40 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PAGE <br />REV: B1 12/10/2024 <br />ISIDRO MENDOZA <br />2701 S POPLAR ST, SANTA ANA, <br />CA, 92704 <br />PROJECT NUMBER: <br />109R-701MEN1 <br />SHEET <br />DESIGNER: <br />VISHNUMAYA KP <br />CUSTOMER RESIDENCE: <br />TEL. (714) 697-7230 <br />APN: 140-273-07 <br />(415) 580-6920 ex3 <br />Template_version_v5_2024 02 28 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />SIGNAGE <br />PV-5.0 <br />#ESTAMP <br />WARNING! <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />POWER SOURCE OUTPUT CONNECTION <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER AND ESS <br />OCPD (IF APPLICABLE). <br />PER CODE(S): NEC 2020: 705.12(B)(3)(2), <br />CEC 2022: 705.12(B)(3)(2) <br />NOTES AND SPECIFICATIONS: <br />SIGNS AND LABELS SHALL <br />MEET THE REQUIREMENTS <br />OF THE CEC 2022 ARTICLE <br />110.21(B), UNLESS SPECIFIC <br />INSTRUCTIONS ARE <br />REQUIRED BY SECTION 690, <br />OR IF REQUESTED BY THE <br />LOCAL AHJ. <br />SIGNS AND LABELS SHALL <br />ADEQUATELY WARN OF <br />HAZARDS USING EFFECTIVE <br />WORDS, COLORS AND <br />SYMBOLS. <br />LABELS SHALL BE <br />PERMANENTLY AFFIXED TO <br />THE EQUIPMENT OR WIRING <br />METHOD AND SHALL NOT BE <br />HAND WRITTEN. <br />LABEL SHALL BE OF <br />SUFFICIENT DURABILITY TO <br />WITHSTAND THE <br />ENVIRONMENT INVOLVED. <br />SIGNS AND LABELS SHALL <br />COMPLY WITH ANSI <br />Z535.4-2011, PRODUCT <br />SAFETY SIGNS AND LABELS, <br />UNLESS OTHERWISE <br />SPECIFIED. <br />DO NOT COVER EXISTING <br />MANUFACTURER LABELS. <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN THE <br />ARRAY. <br />LABEL LOCATION: <br />ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE <br />DISCONNECTING MEANS TO WHICH THE PV SYSTEMS <br />ARE CONNECTED. <br />PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) <br />4" <br />3" <br />ELECTRICAL SHOCK HAZARD <br />WARNING <br />TERMINALS ON LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />LABEL LOCATION: <br />INVERTER(S), AC/DC DISCONNECT(S), <br />AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): NEC 2020: 690.13(B), CEC <br />2022: 690.13(B) <br />! <br />INVERTER 1 <br />PHOTOVOLTAIC DC DISCONNECT <br />MAXIMUM SYSTEM VOLTAGE:VDC550 <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECT(S). <br />PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 <br />WARNING:PHOTOVOLTAIC <br />POWER SOURCE <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />LABEL LOCATION: <br />INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, <br />AT EACH TURN, ABOVE AND BELOW PENETRATIONS, <br />ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. <br />PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022: <br />690.31(D)(2) <br />LABEL LOCATION: <br />INSTALLED WITHIN 3' OF RAPID SHUT DOWN <br />SWITCH PER CODE(S): NEC 2020: 690.56(C)(2), <br />CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />WARNING! <br />SOURCES: UTILITY GRID, <br />BATTERY AND PV SOLAR <br />ELECTRIC SYSTEM <br />THREE POWER SUPPLY <br />LABEL LOCATION: <br />UTILITY SERVICE METER AND MAIN <br />SERVICE PANEL. <br />PER CODE(S): NEC 2020: 705.12(C), CEC <br />2022: 705.12(C) <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br />48 AMPS <br />240 VAC <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 <br />PV SYSTEM DISCONNECT <br />ENERGY STORAGE SYSTEM <br />DISCONNECT <br />LABEL LOCATION: <br />ENERGY STORAGE SYSTEM DISCONNECT <br />PER CODE(S): NEC 2020: 706.15(C), CEC 2022: 706.15(C) <br />ENERGY STORAGE SYSTEM <br />PREMISES WIRING MAY REMAIN <br />ENERGIZED AFTER LOSS OF <br />UTILITY POWER <br />CAUTION! <br />LABEL LOCATION: <br />INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C) <br />CAUTION <br />2701 S POPLAR ST, SANTA ANA, CA, 92704 <br />SOLAR PANELS ON ROOF <br />PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 <br />MULTIPLE SOURCES OF POWER <br />INVERTER AND ENERGY STORAGE <br />(EXT)-PCS CONTROLLED <br />AC DISCONNECT <br />BACKUP GATEWAY <br />SERVICE ENTRANCE AND GATEWAY <br />FEEDER BREAKER <br />(E) PV EQUIPMENT <br />GENERATION AND BACKUP LOADS PANEL <br />RAPID SHUTDOWN SWITCH <br />(E)PV ARRAY <br />RAPID SHUTDOWN DISCONNECT LOCATION <br />(EXISTING SYSTEM AC DISCONNECT) <br />PV SYSTEM(S) ARE <br />EQUIPPED WITH RAPID <br />SHUTDOWN DEVICE(S) <br />2701 S Poplar St <br />3/10/2025
The URL can be used to link to this page
Your browser does not support the video tag.