Laserfiche WebLink
52024Powerwall 3 Datasheet <br />Gateway 3 <br />8 Only Eaton CSR or BWH main breakers are 25 kA rated. <br />Performance <br />Speci￿cations <br />Model Number 1841000-01-y <br />Nominal Grid Voltage 120/240 V AC <br />Grid Con￿guration Split phase <br />Grid Frequency 60 Hz <br />Continuous Current <br />Rating <br />200 A <br />Maximum Supply Short <br />Circuit Current <br />22 kA with Square D or <br />Eaton main breaker <br />25 kA with Eaton main <br />breaker 8 <br />IEC Protective Class Class I <br />Overvoltage Category Category IV <br />Mechanical <br />Speci￿cations <br />Dimensions 660 x 411 x 149 mm <br />(26 x 16 x 6 in) <br />Weight 16.3 kg (36 lb) <br />Mounting options Wall mount <br />Environmental <br />Speci￿cations <br />Operating Temperature –20°C to 50°C (–4°F to 122°F) <br />Operating Humidity (RH)Up to 100%, condensing <br />Maximum Elevation 3000 m (9843 ft) <br />Environment Indoor and outdoor rated <br />Enclosure Type NEMA 3R <br />Compliance <br />Information <br />Certi￿cations UL 67, UL 869A, UL 916, UL 1741 PCS, <br />CSA 22.2 107.1, CSA 22.2 29 <br />Emissions FCC Part 15, ICES 003 <br /> — <br />Tesla Gateway 3 controls connection to the grid in a Powerwall system, automatically detecting outages and providing seamless <br />transition to backup power. It provides energy monitoring that is used by Powerwall for solar self-consumption, time-based <br />control, and backup operation. <br />411 mm <br />660 <br />mm <br />149 <br />mm <br />AC Meter Revenue accurate (+/- 0.5%) <br />Communication CAN <br />User Interface Tesla App <br />Backup Transition Automatic disconnect for <br />seamless backup <br />Overcurrent <br />Protection Device <br />100–200 A <br />Service entrance rated <br />Eaton CSR, BWH, or BW, or <br />Square D QOM breakers <br />Internal Panelboard 200 A <br />8-space/16 circuit breakers <br />Eaton BR, Siemens QP, or <br />Square D HOM breakers rated <br />to 10–125A <br />Warranty 10 years <br />62024Powerwall 3 Datasheet <br />Backup Switch <br />9 Breaker maximum supply short circuit current rating must be equal to or greater than the available fault current. <br />Performance <br />Speci￿cations <br />Model Number 1624171-xx-y <br />Continuous Load Rating 200 A, 120/240 V split phase <br />Maximum Supply Short Circuit Current 22 kA with breaker 9 <br />Communication CAN <br />AC Meter Revenue accurate (+/- 0.5%) <br />Expected Service Life 21 years <br />Warranty 10 years <br />Mechanical <br />Speci￿cations <br />Dimensions 176 x 205 x 74 mm (6.9 x 8.1 x 2.9 in) <br />Weight 2.8 lb <br />Meter and Socket Compatibility ANSI Type 2S, ringless or ring type <br />External Service Interface Contactor manual override 10 <br />Reset button <br />Conduit Compatibility 1/2-inch NPT <br />Environmental <br />Speci￿cations <br />Operating Temperature –40°C to 50°C (–40°F to 122°F) <br />Storage Temperature –40°C to 85°C (–40°F to 185°F) <br />Enclosure Rating NEMA 3R <br />Pollution Rating PD3 <br />Compliance <br />Information <br />Safety Standards USA: UL 414, UL 414 SB, UL 2735, UL 916, CA Prop 65 <br />Emissions FCC, ICES <br />10 Manually overrides the contactor position during a service event. <br /> — <br />The Tesla Backup Switch controls connection to the grid in a Powerwall system, and can be easily installed behind the utility <br />meter or in a standalone meter panel downstream of the utility meter. <br />The Backup Switch automatically detects grid outages, providing a seamless transition to backup power. It communicates <br />directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Tesla app. <br />204.86 <br />74 <br />176 mm <br />205 mm <br />74 mm <br />2701 S Poplar St <br />3/10/2025