Laserfiche WebLink
PAGE <br />REV: C1 1/14/2025 <br />ISIDRO MENDOZA <br />2701 S POPLAR ST, SANTA ANA,  <br />CA, 92704 <br />PROJECT NUMBER: <br />  109R-701MEN1 <br />SHEET <br />DESIGNER: <br />VISHNUMAYA KP <br />CUSTOMER RESIDENCE: <br />TEL. (714) 697-7230 <br />APN: 140-273-07 <br />(415) 580-6920 ex3 <br />Template_version_v5_2024 02 28 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603   <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />COVER SHEET <br />SCOPE OF WORK GENERAL NOTES <br />PV-1.0 <br />VICINITY MAP <br />#SSTAMPCS <br />#ESTAMPCS <br />ABBREVIATIONS <br />A AMPERE <br />AC ALTERNATING CURRENT <br />AFC ARC FAULT CIRCUIT INTERUPTER <br />AZIM AZIMUTH <br />COMP COMPOSITION <br />DC DIRECT CURRENT <br />(E)EXISTING <br />ESS ENERGY STORAGE SYSTEM <br />MSP MAIN SERVICE PANEL <br />(N)NEW <br />PRE-FAB PRE-FABRICATED <br />PSF POUNDS PER SQUARE FOOT <br />PV PHOTOVOLTAIC <br />RSD RAPID SHUTDOWN DEVICE <br />TL TRANSFORMERLESS <br />V VOLTS <br />W WATTS <br />SHEET INDEX <br />PAGE # DESCRIPTION <br />PV-1.0 COVER SHEET <br />PV-2.0 SITE PLAN <br />PV-3.0 LAYOUT <br />PV-3.1 LAYOUT <br />PV-3.2 MOUNTING DETAIL <br />PV-4.0 ELECTRICAL <br />PV-4.1 ELECTRICAL <br />PV-4.2 ELECTRICAL CALCS <br />PV-4.3 BACKUPLOAD CALCS <br />PV-4.4 PANEL SCHEDULE <br />PV-5.0 SIGNAGE <br />PV-5.1 SIGNAGE <br />LTD: LR5-54HABB-395M <br />TESLA: POWERWALL 3 1707000-XX-Y <br />FOOT TO FRAMING, SNR-DC-00339 <br />1707000-XX-Y WITH INTERGRATED INVERTER: 13.5 kWh <br />  TOTAL ENERGY CAPACITY (IN kWh): 27kWH <br />EQUIPMENT INSTALLED, SEE PV-4.0 FOR INTERCONNECTION  <br />DETAILS <br />EXISITNG SOLAR SYSTEM INSTALLED <br />BACKUP GATEWAY: (1) 200A TESLA POWERWALL CONTROL  <br />PANEL <br />CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. <br />SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41(A). <br />MODULES, ARE CLASS A FIRE RATED. <br />CONDUCTORS OUTSIDE OF THE ARRAY ARE LIMITED TO LESS THAN 30V IN 30 <br />SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE <br />ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS <br />ROUTINE MAINTENANCE. SYSTEM VOLTAGE IN ACCORDANCE WITH CEC 706.20 <br />AND EXCEPTION 1 CEC 706.20 (B). <br />CIRCUITS FROM THESE TERMINALS PASS THROUGH A WALL OR PARTITION PER <br />706.15(D). <br />CIRCUIT WIRING IS EXTENDED MORE THAN 6FT AND DOES NOT INCLUDE ANY <br />ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). <br />GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION <br />EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) <br />2701 S Poplar St <br />3/10/2025