Laserfiche WebLink
Highland Manor <br />1128 Highland St <br />Santa Ana, CA, 92703 <br />SHEET NUMBER <br />SH <br />E <br />E <br />T <br /> <br />TI <br />T <br />L <br />E <br />#2 <br />4 <br />2 <br />6 <br />A <br />DAT <br />E <br />JO <br />B <br /> <br />NO. <br />DR <br />A <br />W <br />N <br />PROJECT NAME <br />PROJECT ADDRESS <br />DR <br />A <br />W <br />I <br />N <br />G <br /> <br />LO <br />G <br />DA <br />T <br />E <br />ID <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />12 <br />/ <br />1 <br />2 <br />/ <br />2 <br />4 <br />12 <br />/ <br />2 <br />3 <br />/ <br />2 <br />4 <br />02 <br />/ <br />2 <br />4 <br />/ <br />2 <br />5 <br />01 02 03 <br />PL <br />A <br />N <br />N <br />I <br />N <br />G <br /> <br />SU <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />PR <br />E <br />L <br />I <br />M <br />I <br />N <br />A <br />R <br />Y <br /> <br />B <br />AN <br />D <br /> <br />S <br />SU <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />B <br />AN <br />D <br /> <br />S <br />CO <br />R <br />R <br />E <br />C <br />T <br />I <br />O <br />N <br />S <br /> <br />SU <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br /> <br />#1 <br />A500 <br />TY <br />P <br />E <br /> <br />1 <br />- <br />ST <br />D <br /> <br />UN <br />I <br />T <br /> <br />A/ <br />G <br />/ <br />L <br /> <br />- <br />FL <br />O <br />O <br />R <br /> <br />PL <br />A <br />N <br />, <br /> <br />DE <br />M <br />O <br /> <br />PL <br />A <br />N <br />, <br /> <br />RC <br />P <br />02 <br />/ <br />2 <br />4 <br />/ <br />2 <br />0 <br />2 <br />5 <br />BD <br />G <br />ALL IDEAS, DESIGNS, ARRANGEMENTS <br />AND PLANS INDICATED OR REPRESENTED <br />BY THIS DRAWING ARE OWNED BY AND <br />PROPERTY OF BELL DESIGN GROUP AND <br />WERE CREATED, EVOLVED AND <br />DEVELOPED FOR USE ON AND IN <br />CONNECTION WITH THE SPECIFIED <br />PROJECT. NONE OF SUCH IDEAS, <br />DESIGNS, ARRANGEMENTS, OR PLANS <br />SHALL BE USED BY OR DISCLOSED TO <br />ANY PERSON, FIRM OR CORPORATION <br />FOR ANY PURPOSE WHATSOEVER <br />WITHOUT THE WRITTEN PERMISSION OF <br />BELL DESIGN GROUP. WRITTEN <br />DIMENSIONS SHALL TAKE PRECEDENCE <br />OVER SCALED DIMENSIONS. <br />CONTRACTOR SHALL VERIFY AND BE <br />RESPONSIBLE FOR ALL DIMENSIONS AND <br />CONDITIONS ON THE JOB, AND THIS <br />OFFICE MUST BE NOTIFIED OF ANY <br />VARIATIONS FROM DIMENSIONS AND <br />CONDITIONS SHOWN BY THESE <br />DRAWINGS. <br />BI <br />M <br />c <br />l <br />o <br />u <br />d <br />: <br /> <br />re <br />l <br />a <br />t <br />i <br />v <br />i <br />t <br />y <br /> <br />- <br />BI <br />M <br />c <br />l <br />o <br />u <br />d <br /> <br />So <br />f <br />t <br />w <br />a <br />r <br />e <br /> <br />as <br /> <br />a <br />Se <br />r <br />v <br />i <br />c <br />e <br />/ <br />2 <br />4 <br />2 <br />6 <br />A <br /> <br />Hi <br />g <br />h <br />l <br />a <br />n <br />d <br /> <br />Ma <br />n <br />o <br />r <br />/ <br />2 <br />4 <br />2 <br />6 <br />A <br /> <br />Hi <br />g <br />h <br />l <br />a <br />n <br />d <br /> <br />Ma <br />n <br />o <br />r <br /> <br /> <br /> <br />2/ <br />2 <br />5 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />5: <br />2 <br />5 <br /> <br />PM <br />DEMO STANDARD UNIT PLAN KEYNOTES <br />D1 <br />D2 <br />D3 <br />D4 <br />D5 <br />D6 <br />D7 <br />D8 <br />D9 <br />D10 <br />KITCHEN DEMOLITION, DEMO ALL EXISTING: KITCHEN APPLIANCES, <br />PLUMBING FIXTURES, COUNTERTOPS, LIGHTING, CABINETS, <br />RECEPTACLES & SWITCHES, FLOORING (UNIT A FLOORING TO <br />REMAIN), WALL PER PLAN. <br />BATHROOM DEMOLITION, DEMO ALL EXISTING: PLUMBING <br />FIXTURES (SINK, FAUCET, TOILET, ANGLE STOPS), SHOWER/TUB <br />ENCLOSURES, SHOWER CURTAIN/ROD, ACCESSORIES, VANITY, <br />COUNTERTOP, MIRROR, MEDICINE CABINET, WALL TILE, FLOORING, <br />WALL PER PLAN. <br />POWDER ROOM DEMOLITION, DEMO ALL EXISTING: PLUMBING <br />FIXTURES (SINK, FAUCET, TOILET, ANGLE STOPS), ACCESSORIES <br />(TP HOLDER, TOWER BAR, TOWER RING), VANITY, COUNTERTOPS, <br />MIRROR, MEDICINE CABINET, FLOORING. <br />LIVING ROOM/DINNING/HALLWAY DEMOLITION, DEMO ALL <br />EXISTING: FLOORING (UNIT A FLOORING TO REMAIN), WALL PER <br />PLAN. <br />BEDROOM DEMOLITION, DEMO ALL EXISTING: FLOORING (UNIT A <br />FLOORING TO REMAIN), WALL PER PLAN. <br />DEMO EXISTING EXHAUST FAN AND HEATING COMBO. <br />DEMO EXISTING SMOKE DETECTOR / CO DETECTOR. <br />REFURBISH EXISTING WINDOWS. <br />WATER HEATER: EXISTING TO REMAIN <br />REMOVE EXISTING DOOR HARDWARE, EXISTING DOOR PANELS TO <br />REMAIN. <br />APPEARS IN <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLAN NOTES <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />INSTALL NEW RECEPTACLES AND SWITCHES COVER PLATE <br />THROUGHOUT. <br />REMOVE NON-PROGRAMMABLE THERMOSTAT THROUGHOUT. <br />INSTALL NEW PROGRAMMABLE THERMOSTAT, PER T-24 <br />GUIDELINES. <br />INSTALL NEW WIRED SMOKE DETECTOR AND CARBON MONOXIDE <br />DETECTOR THROUGHOUT. <br />PROVIDE NEW FURNACE AND GRILLE COVER. <br />PROVIDE NEW UP-TO-CODE ELECTRICAL PANEL. <br />CONTRACTOR TO VERIFY ALL WINDOWS AND DOORS' TYPE, SIZE <br />AND QUANTITY IN FIELD. <br />NEW INTERIOR PREP, PRIME, AND PAINT THROUGHOUT. <br />INSTALL NEW 4'' WALL BASE THROUGHOUT. <br />F O <br />D1 <br />D3 <br />D4 <br />D2 <br />D4 <br />D6 <br />D8 <br />D7 <br />D8 <br />D8 <br />D8 <br />D5 D5 <br />D5 <br />D8 <br />D7D8D7 <br />D8D7 <br />D10 <br />D10 <br />D10 <br />D10 D10 <br />D10 <br />1 <br />2 <br />SD <br />SDSD <br />SD <br />SD <br />C6 C6 <br />C6 <br />F <br />C6 <br />C6 <br />L-01 <br />L-01 <br />L-01 <br />L-01 <br />L-01 <br />C <br />C <br />L-01 <br />C <br />PT-03 <br />PT-03 <br />PT-03 <br />PT-03 <br />PT-03PT-03 <br />RG <br />PT-03 <br />PT-03 <br />C6 <br />C2 <br />C3 <br />C4 <br />C5 <br />C4 <br />F <br />C8 <br />C9 <br />C1 <br />C9 <br />C9 <br />C9 <br />C9 <br />C10 <br />C8C5C9C8 <br />C5 C9C8 <br />C12 <br />C11 <br />C11C11 <br />C11 <br />C11 <br />C13 <br />L <br />1 <br />A501 <br />1 <br />A501 <br />FL-01 <br />FL-01 <br />LIVING ROOM <br />KITCHEN <br />BEDROOM 2 <br />BEDROOM 3 <br />BEDROOM 1 <br />BATHROOM 2 <br />BATHROOM 1 <br />(N) FURNACE <br />(E) WATER <br />HEATER <br />RG <br />LIGHTING FIXTURES LEGEND <br />SD/CO <br />C <br />L-0X <br />EXHAUST FAN/ HEATING COMBO <br />SMOKE DETECTOR AND CABON MONOXIDE DETECTOR <br />ELECTRICAL PANEL <br />CEILING FAN <br />LINEAR LED LIGHT <br />RECESSED CAN LIGHT <br />CONSTRUCTION STANDARD UNIT KEYNOTES <br />C1 <br />C2 <br />C3 <br />C4 <br />C5 <br />C6 <br />C7 <br />C8 <br />C9 <br />C10 <br />C11 <br />C12 <br />C13 <br />KITCHEN: PROVIDE NEW KITCHEN APPLIANCES, PLUMBING <br />FIXTURES, COUNTERTOPS, CABINETS, LIGHTING, RECEPTACLES & <br />SWITCHES, FLOORING, WALL PER PLAN. <br />BATHROOM: PROVIDE NEW PLUMBING FIXT. (SINK, FAUCET, TOILET, <br />ANGLE STOPS), TUB ENCLOSURES, SHOWER CURTAIN/ROD, <br />ACCESSORIES (TP HOLDER, TOWER BAR, TOWER RING), VANITY, <br />COUNTERTOP, MIRROR, MEDICINE CABINET, WALL TILE, FLOORING, <br />WALL PER PLAN. <br />POWDER ROOM: PROVIDE NEW PLUMBING FIXTURES (SINK, <br />FAUCET, TOILET, ANGLE STOPS), ACCESSORIES (TP HOLDER, <br />TOWER BAR, TOWER RING), VANITY, COUNTERTOPS, MIRROR, <br />MEDICINE CABINET, FLOORING. <br />LIVING ROOM/DINING/HALLWAY: PROVIDE NEW FLOORING (UNIT A <br />FLOORING TO REMAIN), WALL PER PLAN. <br />BEDROOM: PROVIDE NEW FLOORING (UNIT A FLOORING TO <br />REMAIN), WALL PER PLAN. <br />NEW CEILING FAN/HEATER/LIGHTING COMBO <br />PROVIDE NEW HARD-WIRED WALL MOUNTED EXHAUST FAN PER <br />PLAN. <br />PROVIDE NEW SMOKE DETECTOR / CO DETECTOR. <br />REFURBISHED WINDOWS. <br />WATER HEATER: EXISTING TO REMAIN <br />REPLACE EXISTING DOOR HARDWARE. PROVIDED DOOR LEVER <br />SET TO COMPLY WITH 11B-404.2.7. REF DOOR AND HARDWARE <br />NOTES ON A610. REPAIR TRIM AS NEEDED. <br />REPLACE EXISTING DOOR HARDWARE AT ENTRY DOOR AND <br />SCREEN DOOR. PROVIDED DOOR LEVER SETS TO COMPLY WITH <br />11B-404.2.7 AND THRESHOLD TO COMPLY WITH 11B-404.2.5. REF <br />DOOR AND HARDWARE NOTES ON A610. <br />PROVIDE NEW HARD-WIRED CEILING MOUNTED HEATER / <br />EXHAUST FAN / LIGHTING COMBO PER PLAN <br />APPEARS IN <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />UNIT PLANS <br />LEGEND <br />(N) LVT FLOORING <br />SOFFIT CEILING <br />NEW WALL <br />TO BE DEMO <br />03 <br />SCALE: 1/4" = 1'-0"1STD. UNIT A, G, L - TYPE 1 DEMO <br />SCALE: 1/4" = 1'-0"3STD. UNIT A, G, L - TYPE 1 RCP <br />SCALE: 1/4" = 1'-0"2STD. UNIT A, G, L - TYPE 1 PROPOSED <br />EXHAUST FAN/ LIGHTING/ HEATING COMBO <br />1128 W Highland St <br />3/27/2025