Laserfiche WebLink
PAGE <br />REV: B 3/20/2025 <br />ANGELA SAMPSON <br />3340 S CRAWFORD GLEN, <br />SANTA ANA, CA, 92704 <br />PROJECT NUMBER: <br />109R-340SAMP <br />SHEET <br />DESIGNER: <br />VISHNUMAYA KP <br />CUSTOMER RESIDENCE: <br />TEL. (714) 642-8754 <br />APN: 412-521-03 <br />(415) 580-6920 ex3 <br />Template_version_v5_2024 02 28 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />SIGNAGE <br />PV-5.0 <br />NOMINAL ESS VOLTAGE VAC <br />LABEL LOCATION: <br />ENERGY STORAGE SYSTEM <br />PER CODE(S): NEC 706.15(C), CEC 706.15(C) <br />120/240 <br />520 VDC MAXIMUM ESS DC VOLTAGE:60 <br />ENERGY STORAGE SYSTEM DISCONNECT <br />WARNING! <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />POWER SOURCE OUTPUT CONNECTION <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER AND ESS <br />OCPD (IF APPLICABLE). <br />PER CODE(S): NEC 2020: 705.12(B)(3)(2), <br />CEC 2022: 705.12(B)(3)(2) <br />NOTES AND SPECIFICATIONS: <br />SIGNS AND LABELS SHALL MEET THE <br />REQUIREMENTS OF THE CEC 2022 <br />ARTICLE 110.21(B), UNLESS SPECIFIC <br />INSTRUCTIONS ARE REQUIRED BY <br />SECTION 690, OR IF REQUESTED BY <br />THE LOCAL AHJ. <br />SIGNS AND LABELS SHALL <br />ADEQUATELY WARN OF HAZARDS <br />USING EFFECTIVE WORDS, COLORS <br />AND SYMBOLS. <br />LABELS SHALL BE PERMANENTLY <br />AFFIXED TO THE EQUIPMENT OR <br />WIRING METHOD AND SHALL NOT BE <br />HAND WRITTEN. <br />LABEL SHALL BE OF SUFFICIENT <br />DURABILITY TO WITHSTAND THE <br />ENVIRONMENT INVOLVED. <br />SIGNS AND LABELS SHALL COMPLY <br />WITH ANSI Z535.4-2011, PRODUCT <br />SAFETY SIGNS AND LABELS, UNLESS <br />OTHERWISE SPECIFIED. <br />DO NOT COVER EXISTING <br />MANUFACTURER LABELS. <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN THE <br />ARRAY. <br />LABEL LOCATION: <br />ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE <br />DISCONNECTING MEANS TO WHICH THE PV SYSTEMS <br />ARE CONNECTED. <br />PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) <br />4" <br />3" <br />ELECTRICAL SHOCK HAZARD <br />WARNING <br />TERMINALS ON LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />LABEL LOCATION: <br />INVERTER(S), AC/DC DISCONNECT(S), <br />AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): NEC 2020: 690.13(B), CEC <br />2022: 690.13(B) <br />! <br />INVERTER 1 <br />PHOTOVOLTAIC DC DISCONNECT <br />MAXIMUM SYSTEM VOLTAGE:VDC550 <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECT(S). <br />PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />LABEL LOCATION: <br />INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, <br />AT EACH TURN, ABOVE AND BELOW PENETRATIONS, <br />ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. <br />PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022: <br />690.31(D)(2) <br />LABEL LOCATION: <br />INSTALLED WITHIN 3' OF RAPID SHUT DOWN <br />SWITCH PER CODE(S): NEC 2020: 690.56(C)(2), <br />CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />WARNING! <br />SOURCES: UTILITY GRID, <br />BATTERY AND PV SOLAR <br />ELECTRIC SYSTEM <br />THREE POWER SUPPLY <br />LABEL LOCATION: <br />UTILITY SERVICE METER AND MAIN <br />SERVICE PANEL. <br />PER CODE(S): NEC 2020: 705.12(C), CEC <br />2022: 705.12(C) <br />THIS EQUIPMENT FED BY <br />MULTIPLE SOURCES. TOTAL <br />RATING OF ALL OVERCURRENT <br />DEVICES EXCLUDING MAIN <br />SUPPLY OVERCURRENT DEVICE <br />SHALL NOT EXCEED AMPACITY OF <br />BUSBAR <br />WARNING! <br />LABEL LOCATION: <br />PV LOAD CENTER (IF APPLICABLE) AND <br />ANY PANEL THAT UTILIZES "THE SUM <br />OF BREAKERS RULE". <br />PER CODE(S): NEC 2020: 705.12 (B)(3)(3), <br />CEC 2022: 705.12 (B)(3)(3) <br />CAUTION <br />3340 S CRAWFORD GLEN, SANTA ANA, CA, 92704 <br />PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 <br />MULTIPLE SOURCES OF POWER <br />AC DISCONNECT <br />BACKUP GATEWAY WITH PV + ESS BREAKER <br />SOLAR PANELS ON ROOF <br />INVERTER AND ENERGY <br />STORAGE 2 (EXT) <br />SERVICE ENTRANCE AND LUGKIT <br />BACKUP LOADS PANEL <br />RAPID SHUTDOWN SWITCH (EXT)MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br />48 AMPS <br />240 VAC <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 <br />PV SYSTEM DISCONNECT <br />ENERGY STORAGE SYSTEM <br />PREMISES WIRING MAY REMAIN <br />ENERGIZED AFTER LOSS OF <br />UTILITY POWER <br />CAUTION! <br />LABEL LOCATION: <br />INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C) <br />INVERTER AND ENERGY <br />STORAGE 1 (EXT) <br />EXPANSION ENERGY <br />STORAGE (EXT) <br />AC DISCONNECT <br />3340 S Crawford <br />Glen4/28/2025