My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3340 S Crawford Glen - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Crawford Glen
>
3340 S Crawford Glen
>
3340 S Crawford Glen - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2025 12:44:26 PM
Creation date
6/15/2025 12:44:00 PM
Metadata
Fields
Template:
Plan
Permit Number
20185449
Full Address
3340 S Crawford Glen
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> <br /> <br /> <br /> <br /> <br /> <br />This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms <br />and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this <br />Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, <br />product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This <br />Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. <br /> <br /> <br /> <br />Intertek Page 5 of 8 GFT-OP-11a (22-August-2019) <br /> <br />Appendix 3: List of Tested Grid protection / Support Function: <br />Table 3A: Test List -1 <br />Grid protection / Support <br />Function Tested <br />Test Standards Sections and Source Requirement Documents <br />IEEE 1547- <br />2018 <br />IEEE 1547.1- <br />2020 <br />UL 1741SB - <br />2021 CA Rule 21:2020 <br />UL 1741 SRD <br />V2.0 <br />(HECO):2020 <br />OPERATIONAL TEMPERATURE -- 5.3.3.1 SB4.3.5.3 -- Same as 1547- <br />2018 <br />PROTECTION FROM <br />ELECTROMAGNETIC <br />INTERFERENCE (EMI) TEST <br />4.11.1 5.8.1 SB4.3.5.8.1 -- Same as 1547- <br />2018 <br />SURGE WITHSTAND <br />PERFORMANCE TEST 4.11.2 5.8.2 SB4.3.5.8.2 -- Same as 1547- <br />2018 <br />PARALLELING DEVICE 4.11.3 5.8.3 -- -- Same as 1547- <br />2018 <br />OVERVOLTAGE TRIP 6.4.1 5.4.2 SB4.3.5.4.2 Electric Rule No. <br />21 Table Hh.1 <br />Same as 1547- <br />2018 <br />UNDERVOLTAGE TRIP 6.4.1 5.4.3 SB4.3.5.4.3 Electric Rule No. <br />21 Table Hh.1 <br />Same as 1547- <br />2018 <br />OVERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2 <br />SB4.3.5.5.1 <br />& <br />SB4.3.5.5.2 <br />Electric Rule No. <br />21 Table Hh.2 <br />Same as 1547- <br />2018 <br />UNDERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2 <br />SB4.3.5.5.1 <br />& <br />SB4.3.5.5.2 <br />Electric Rule No. <br />21 Table Hh.2 <br />Same as 1547- <br />2018 <br />LOW VOLTAGE RIDE-THROUGH 6.4.2.3 & <br />6.4.2.5 5.4.4 SB4.3.5.4.4 Electric Rule No. <br />21 Table Hh.1 <br />Same as 1547- <br />2018 <br />HIGH VOLTAGE RIDE-THROUGH 6.4.2.4 5.4.7 SB4.3.5.4.7 Electric Rule No. <br />21 Table Hh.1 <br />Same as 1547- <br />2018 <br />LOW FREQUENCY RIDE-THROUGH 6.5.2.3 5.5.3 SB4.3.5.5.3 Electric Rule No. <br />21 Table Hh.2 <br />SRD-UL-1741-SA- <br />V2.0 (HECO) Part <br />II B <br />HIGH FREQUENCY RIDE- <br />THROUGH 6.5.2.4 5.5.4 SB4.3.5.5.4 Electric Rule No. <br />21 Table Hh.2 <br />SRD-UL-1741-SA- <br />V2.0 (HECO) Part <br />II B <br />RATE OF CHANGE OF FREQUENCY 6.5.2.5 5.5.5 -- -- Same as 1547- <br />2018 <br />ANTI-ISLANDING PROTECTION - <br />WITH GRID SUPPORT FUNCTIONS <br />ENABLED <br />8.1 5.10.2 SB4.3.5.10.2 Electric Rule No. <br />21 Hh.1a <br />According to UL <br />1741 SA-V2.0 <br />(HECO) <br />TEST FOR VOLTAGE PHASE-ANGLE <br />CHANGE RIDE-THOUGH <br />(VARIATION 1) <br />6.5.2.6 5.5.6.1 SB4.3.5.5.6 -- Same as 1547- <br />2018 <br />ENTER SERVICE 4.10 5.6 -- -- Same as 1547- <br />2018 <br />SYNCHRONIZATION CONTROL <br />FUNCTION TEST FOR EQUIPMENT <br />WITH NO SYNCHRONIZING <br />DISABLE CAPABILITY (VARIATION <br />3) <br />6.3 5.7.4 -- -- Same as 1547- <br />2018 <br />LIMITATION OF DC INJECTION <br />FOR INVERTERS 7.1 5.9 -- Electric Rule No. <br />21 Hh.2h <br />Same as 1547- <br />2018 <br />OPEN PHASE 6.2.2 5.11 -- -- Same as 1547- <br />2018 <br />CURRENT DISTORTION 7.3 5.12 -- Electric Rule No. Same as 1547- <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms <br />and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this <br />Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, <br />product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This <br />Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. <br /> <br /> <br /> <br />Intertek Page 6 of 8 GFT-OP-11a (22-August-2019) <br /> <br />Grid protection / Support <br />Function Tested <br />Test Standards Sections and Source Requirement Documents <br />IEEE 1547- <br />2018 <br />IEEE 1547.1- <br />2020 <br />UL 1741SB - <br />2021 CA Rule 21:2020 <br />UL 1741 SRD <br />V2.0 <br />(HECO):2020 <br />21 Hh.2g 2018 <br />LIMIT ACTIVE POWER 4.6.2 5.13 -- Electric Rule No. <br />21 Hh.8 <br />Same as 1547- <br />2018 <br />CONSTANT POWER FACTOR 5.3.2 5.14.3 SB4.3.5.14.3 Electric Rule No. <br />21 Hh.2i <br />Same as 1547- <br />2018 <br />VOLTAGE-REACTIVE POWER <br />(VOLT-VAR) MODE FIXED VREF 5.3.3 5.14.4 SB4.3.5.14.4 Electric Rule No. <br />21 Hh.2J <br />Same as 1547- <br />2018 <br />VOLTAGE-REACTIVE POWER <br />(VOLT-VAR) MODE (VREF TEST) 5.3.3 5.14.5 SB4.3.5.14.5 -- Same as 1547- <br />2018 <br />ACTIVE POWER-REACTIVE POWER <br />MODE (WATT-VAR) 5.3.4 5.14.7 SB4.3.5.14.7 -- Same as 1547- <br />2018 <br />CONSTANT REACTIVE POWER <br />(VAR) MODE 5.3.5 5.14.8 SB4.3.5.14.8 -- Same as 1547- <br />2018 <br />VOLTAGE-ACTIVE POWER (VOLT- <br />WATT) MODE 5.4 5.14.9 SB4.3.5.14.9 Electric Rule No. <br />21 Hh.2.m <br />Same as 1547- <br />2018 <br />TEST FOR FREQUENCY -DROOP <br />(FREQUENCY-POWER OR <br />FREQUENCY-WATT) CAPABILITY — <br />ABOVE NOMINAL FREQUENCY <br />6.5.2.7 5.15.2 SB4.3.5.15.2 Electric Rule No. <br />21 Hh.2.l <br />SRD-UL-1741-SA- <br />V2.0 (HECO) Part <br />II C <br />TEST FOR FREQUENCY -DROOP <br />(FREQUENCY-POWER OR <br />FREQUENCY-WATT) CAPABILITY — <br />BELOW NOMINAL FREQUENCY <br />6.5.2.7 5.15.3 SB4.3.5.15.3 Electric Rule No. <br />21 Hh.2.l <br />SRD-UL-1741-SA- <br />V2.0 (HECO) Part <br />II C <br />PRIORITIZATION OF DER <br />RESPONSES 4.7 5.16 SB4.3.5.16 -- Same as 1547- <br />2018 <br />LOAD REJECTION OVERVOLTAGE <br />(LROV) 7.4 5.17.2 SB4.3.5.17.2 -- Same as 1547- <br />2018 <br />FAULT CURRENT TESTS FOR <br />INVERTERS 6.2.1 5.18.1 -- -- Same as 1547- <br />2018 <br />PERSISTENCE OF DER PARAMETER <br />SETTINGS -- 5.19 -- -- Same as 1547- <br />2018 <br />NORMAL RAMP RATE -- -- -- Electric Rule No. <br />21 Hh.2k -- <br />NAMEPLATE DATA TEST 10.3 6.4 -- -- Same as 1547- <br />2018 <br />MONITORING INFORMATION <br />TEST 10.5 6.6 SB4.3.6.6 -- Same as 1547- <br />2018 <br />MANAGEMENT INFORMATION <br />TEST 10.6 6.7 SB4.3.6.7 -- Same as 1547- <br />2018 <br /> <br />3340 S Crawford <br />Glen4/28/2025
The URL can be used to link to this page
Your browser does not support the video tag.