2" <br />5/8" <br />1 EQUIPMENT ANCHORING DETAIL <br />2 EQUIPMENT SIDE PANEL TO SIDE PANEL DETAIL <br />3 SIDE PANEL TO ROOF PANEL DETAIL <br />4 EQUIPMENT CORNER PANEL ASSEMBLY DETAIL <br />5/16" X3/4" NUT AND BOLT, <br />6" O.C.. <br />18 GA GALV. STEEL <br />PANELS <br />ALL SEAMS TO BE CAULKED <br />18 GA GALV. STEEL <br />ROOF PANEL <br />18 GA GALV. STEEL <br />SIDE PANEL <br />ALL SEEMS TO BE CAULKED <br />5/16" X3/4" NUT AND BOLT, <br />6" O.C. <br />Z-BAR <br />5/16" x 3/4" NUT <br />AND BOLT, 6" O.C. <br />18 GA. GALV. STEEL <br />SIDE PANEL <br />18 GA GALV. STEEL <br />ROOF PANEL <br />ALL SEEMS TO BE CAULKED <br />6 MANOMETER DETAIL <br />5 EQUIPMENT LIGHTING MOUNT DETAIL <br />7 ARTICLE 516 TOP VIEW <br />8 ARTICLE 516 ELEVATION VIEW 10 DUCT PENETRATION THROUGH ROOF DETAIL <br />9 TYP. DUCT ASSEMBLY & ROOF PENETRATION DETAIL <br />5/16" x 3/4" NUT <br />AND BOLT, 6" O.C. <br />4 LIGHT TUBE FIXTURE <br />18 GA GALV. STEEL <br />PANEL <br />MOUNTING FRAME <br />18 GA GALV. STEEL <br />18 GA GALV. STEEL <br />PANEL <br />1/2" x 3/8" <br />FOAM GASKET <br />Dwyer <br />RUN RUBBER TUBING FROM HIGH TO BRASS <br />FITTING IN SPRAY AREA WALL <br />SLOWLY FILL WITH RED <br />OIL UNTIL IT APPEARS <br />IN GAGE <br />CALIBRATE UNTIL <br />MENISCUS REACHES <br />ZERO <br />RUN RUBBER TUBING FROM LOW TO BRASS <br />FITTING IN EXHAUST CHAMBER WALL <br />MANOMETER TO BE MOUNTED ON WALL PANEL <br />SEE ELEVATION FOR PLACEMENT <br />LEVELING VIAL <br />RECOMMEND ARRESTOR CHANGE AT .3 INCHES OF <br />WATER <br />5 FT. R <br />(915 MM) <br />ENCLOSED SPRAY BOOTH OR ROOM <br />(CLASS I, DIVISION I OR <br />CLASS II, DIVISION I WITHIN) <br />3 ft. R 3 ft. R <br />CLASS I OR CLASS II, DIVISION 2. LOCATION ADJACENT TO <br />OPENINGS IN AN ENCLOSED SPRAY BOOTH OR ROOM <br />5 FT. R <br />(915 MM) <br />EXTEND OF CLASS I OR CLASS II, DIVISION 2 AREA <br />5 FT. R <br />(915 MM) <br />3 FT. R <br />(915 MM) <br />3 FT. R <br />(915 MM) <br />3 FT. R <br />(915 MM) <br />STACK CAP 20. GA. <br />GALVANIZED STEEL <br />SECURITY BARS TO BE <br />INSTALLED IN DUCT <br />DUCT 20 GA. <br />GALVANIZED STEEL <br />ROOF JACK FLASHING <br />2X FRAMING SUPPORTS (TYP.) <br />FIRE SPRINKLERS DOOR TO BE <br />PROVIDED BY CMC 2022, 506.6 <br />13" X 15" CLEAN OUT DOOR <br />W/ LATCH REQUIRED AT <br />SPRINKLER HEAD LOCATION <br />20 GA. GALVANIZED STEEL <br />@ 10'O.C. PER CMC 506.3 <br />INSULATED THIMBLE CONSIST OF <br />24 GA. SHEET METAL OVER 1" <br />GLASS FIBER REINFORCED W/ <br />WIRE ON REAR FACE W/ A 2" AIR <br />GAP (PER CMC 2022, 506.7) <br />ROOF JACK STACK <br />EXHAUST OUTLET TERMINATION POINT <br />SHALL BE 6' MIN. ABOVE ROOF AND 10' MIN. <br />FROM ANY OPEN'G IN THE BUILDING <br />PER 2022 CFC SECTION 2404.7.6 <br />18 <br />" <br />18 <br />" <br />10 <br />- <br />Ø42" FAN <br />TUBEAXIAL EXHAUT FAN <br />(SEE EQUIPMENT SCHEDULE FOR SPECS) <br />3" CLEARANCE ALL AROUND DUCT <br />ROOF SEALANT (ALL AROUND-TYP.) <br />6" <br />5/16" x 3/4" NUT <br />AND BOLT, 6" O.C. <br />POWER BULL WEDGE ANCHORS <br />Ø3/8" X 3" W/ 2" EMBEDMN'T <br />@ 36" O.C. (ESR-2254) <br />SIDE PANEL 18 GA <br />GALV. STEEL <br />FLOOR RAIL 14 GA. <br /> GALV. STEEL <br />(E) 6" CONCRETE SLAB <br />NEW 2 x 4 SUB- MEMBERS <br />(TYP. OF 4 LOCATIONS) <br />NEW 2 x 4 MEMBER TO <br />REINFORCE JOIST <br />DOUBLE JOIST SUPPORTS (2x4) <br />SIMPSON STRONG TIE LU-24 <br />ESR 3096 (TYP.) <br />NOTE: ALL NAILING OF 2X4 MEMBERS <br />TO BE 2-16d COMMONS @ 6" O.C. <br />INSULATED THIMBLE <br />W/ 2" AIR GAP <br />(PER CMC 2022, 506.7) <br />EXISTING 2x4 SUB-MEMBERS <br />14 GA. DUCT CLIP ATTACHED <br />TO DUCT TO SECURE- STABILIZE <br />DUCT@ ROOF LINE (TYP.) <br />NEW 2 x 4 MEMBER TO <br />REINFORCE JOIST <br />EXISTING 2 x 4 SUB-MEMBERS <br />DOUBLE JOIST SUPPORTS (2x4) <br />SIMPSON STRONG TIE LU-24 <br />ESR 3096 (TYP.) <br />NOTE: ALL NAILING OF 2X4 MEMBERS <br />TO BE 2-16d COMMONS @ 6" O.C. <br />Ø42" DUCT <br />NOTES: <br />1. SPACERS AND TIES FOR PROTECTION MATERIALS SHALL BE OF NONCOMBUSTIBLE MATERIAL AND SHALL NOT BE USED DIRECTLY BEHIND THE DUCT PER CMC 2022 <br /> SECTION 506.7.1. <br />2. SPACING OF SUPPORTS FOR DUCTS SHALL NOT EXCEED TWELVE (12) FEET (3,658 MM) FOR EIGHT (8) INCH (203 MM) DUCTS NOR TWENTY (20) FEET (6,096 MM <br /> FOR LARGER DUCT, UNLESS JUSTIFIED BY THE DESIGN. LOADS SHALL NOT BE PLACED ON CONNECTING EQUIPMENT PER CMC 2022, 506.5. <br />3. ALL DUCTWORK AND SYSTEM COMPONENTS HANDLING COMBUSTIBLE MATERIAL AND OPERATING AT LESS THAN 140°F SHALL HAVING A CLEARANCE OF NOT LESS <br /> THAN EIGHTEEN (18) INCHES FROM COMBUSTIBLE CONSTRUCTION OR ANY COMBUSTIBLE MATERIAL. <br /> NOTE: ALL COMBUSTIBLE CONSTRUCTION WITHIN (18) INCHES OF DUCT SHALL BE PROTECTED USING (NO. 24 GA.) SHEET METAL WITH NOT LESS THAN A ONE INCH AIR GAP. <br /> THE PRESCRIPTIVE MATERIAL IS APPLIED TO THE COMBUSTIBLE CONSTRUCTION INCLUDING THE WALL AND CEILING AREA PER CMC SECTION 506.7. <br />OPENING SIZE VARIES <br />PER DUCT SIZE <br />1" CLEAR SPACE <br />3" <br />SHEET #: <br />Q-2 <br />SHEET CONTENTS: <br />EQUIPMENT ASSEMBLY <br />& DETAILS <br />CLIENT: <br />PROJECT: <br />INSTALL PAINT <br />SPRAY BOOTH <br />CONTRACTOR: <br />REVISIONS <br />SCALE: N.T.S. <br />DATE:08/24/24 <br />CHECKED BY: M.M. <br />DRAWN BY: P. A. <br />NO.DESCRIPTION DATE <br />ADVANCED FIBERGLASS <br />CONCEPTS <br />2907 OAK ST. <br />SANTA ANA, CA 92707 <br />WARNING: This document is for the use of licensed users <br />only. Any Unauthorized copying, distribution, or <br />disclosure of information is a violation of copyright laws. <br />No reproduction in whole or in part of this document may <br />be made without the written consent of <br />MDI Spray Systems. <br />MDI Spray Systems <br />888 E. 1st Street <br />Pomona, CA 91766 <br />www.mdispraysystems.com <br />LIC.#499372, CLASS B, C-16 <br />EXPIRES: 05/31/25 <br />2907 S Oak St <br />4/24/2025