Laserfiche WebLink
GFI <br />WP <br />WP <br />220V <br />EGD <br />3 <br />4 <br />D <br />220 <br />vs <br />FS <br />CT <br />R <br />CLG <br />SD <br />T <br />H <br />J <br />W <br />TV <br />AC <br />CONDENSER <br />WATER <br />HEATER <br />IAQ FAN <br />IAQ FAN <br />AC RETURN <br />AIR VENT <br />GAS <br />GAS <br />AC RETURN <br />AIR VENT <br />ATTIC <br />ACCESS <br />ATTIC <br />ACCESS <br />(N) OUTDOOR <br />AC UNITS <br />(E) WATER <br />HEATER WITH <br />ENCLOSURE <br />ELECTRICAL SYMBOLS <br />DUPLEX RECEPTACLE MOUNTED IN CEILING FOR GARAGE DOOR <br />OPENER <br />FLOOR MTD. RECEPTACLE POL BRASS <br />RECEPTACLE 1/2 SWITCHED <br />SINGLE POLE SWITCH <br />3 WAY SWITCH <br />4 WAY SWITCH <br />DUPLEX RECEPTACLE ON ALL BRANCH CIRCUITS THAT SUPPLY 125- <br />VOLT, SINGLE-PHASE, 15 & 20AMP RECEPTACLE OUTLETS IN DWELLING <br />UNIT SHALL BE PROTECTED BY A COMBINATION TYPE (AFCI) ARC- <br />FAULT CIRCUIT INTERRUPTER(S) PER 2010 CEC 210.12. <br />FUSED SWITCH <br />WATERPROOF RECEPTACLE <br />DUPLEX RECEPTACLE ON GROUND-FAULT INTERRUPTED CIRCUIT <br />DUPLEX RECEPTACLE LOCATED UNDER COUNTER <br />220V RECEPTACLE (VERIFY AMPERAGE REQUIREMENTS) <br />RECESSED HIGH EFFICACY LIGHT FIXTURE <br />WEATHER PROOF <br />VAPOR PROOF, RECESSED, HIGH EFFICACY LIGH FIXTURE <br />HANGING HIGH EFFICACY LIGHT FIXTURE - CHANDELIER I00 LB <br />SUPPORT MIN. <br />WALL MOUNTED HIGH EFFICACY LIGHT FIXTURE <br />SURFACE MOUNTED HIGH EFFICACY LIGHT FIXTURE <br />SOLAR POWERED, PHOTOCONTROL STEP MOUNTED LIGHT FIXTURE <br />VENT / LIGHT COMBO, BY VENT AXIA <br />CEILING EXHAUST FAN / FLUORESCENT LIGHT WHISPER FIT 4" <br />DUCT. PANASONIC OR EQUAL <br />STANDARD SERVICE TELEPHONE OUTLET <br />CAT 5 COMBINED: COMPUTER DATA LINE AND TELEVISION CABLE OUTLET <br />SMOKE DETECTOR SHALL BE PROTECTED BY AND ARC-FAULT CIRCUIT <br />INTERRUPTER PER 2019 CEC 210.10. SMOKE DETECTORS SHALL HAVE A 10 <br />YEAR BATTERY AND SHALL BE REPLACED 10 YEARS FROM THE DATE <br />MARKED ON THE UNIT PER 2019 CBC 907.2.11.2, AND 2019 CRC R314 - R315. <br />GAS LINE <br />HOSE BIB <br />JUNCTION BOX <br />HEATING OUTLET <br />IAQ FAN <br />HUMIDISTAT CONTROL <br />VACANCY LIGHT SWITCH <br />220 VOLT FUSED SWITCH <br />SINGLE POLE SWITCH WITH DIMMER <br />THERMOSTAT <br />CARBON MONOXIDE <br />ELECTRIC VEHICLE CHARGER <br />VACANCY SENSOR <br />UNDER-CABINET LED STRIP LIGHT <br />DUPLEX RECEPTACLE LOCATED ABOVE CEILING <br />CEILING EXHAUST FAN PANASONIC WHISPER FIT FAN 4" DUCT WITH <br />HUMIDITY CONTROL <br />HB <br />GAS <br />VS <br />CM <br />EVC <br />C5 <br />S <br />VP <br />DUPLEX RECEPTACLE FOR TELEVISION <br />ELECTRIC PANEL <br />INDOOR AIR HANDLER, MINI-SPLITAC <br />F <br />H <br />ELECTRICAL ABBREVIATIONS <br />A AMP <br />AT AUTOMATIC TIME SWITCH CONTROL <br />AST ASTRONOMICAL TIME CLOCK <br />C/CW COLD WATER <br />D DIMMER / DIMMABLE <br />DED DEDICATED OUTLET / CIRCUIT <br />EMCS EMERGENCY MANAGEMENT CONTROL <br />SYSTEM (CENC 105 (K) 3,A,III,C) <br />EV ELECTRICAL VEHICLE <br />EVSE ELECTRIC VEHICLE SUPPLY EQUIPMENT <br />FAU FORCED AIR UNIT <br />FG NATURAL GAS <br />FL FLOURESCENT <br />FSR FIRE SPRINKLER RISER <br />GFI GROUND FAULT CIRCUIT INTERRUPTER <br />HB HOSE BIB <br />HC HUMIDISTAT CONTROL <br />HE HIGH EFFICACY <br />H/HW HOT WATER <br />JA8 COMPLAINT W/ APPENDIZ JA8 <br />L, LED LED LIGHT FIXTURE <br />LVL EVSE LEVEL <br />MR MOISTURE RESISTANT (INDOOR) <br />MS MOTION SENSOR <br />PB PUSH BUTTON <br />PC PHOTOCELL <br />SOV SHUT OFF VALVE <br />VS VACANCY SENSOR <br />V VOLT <br />WP WEATHER PROOF (RATED FOR <br />EXTERIOR) <br />ELECTRICAL NOTES <br />CODE REFERENCES BASED ON <br />2022 CALIFORNIA ELECTRICAL CODE <br />1 <br />MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS ARE SHOWN FOR INTENT ONLY. THESE <br />SYSTEMS SHALL BE ENGINEERED BY OTHERS. THE CONTRACTOR SHALL BE RESPONSIBLE <br />FOR PROPER INSTALLATION AND PLACEMENT. <br />2 <br />3 <br />4 <br />5 <br />NUMBER OF CEILING JUNCTION BOXES NOT CONTAINING INSTALLED LIGHTING OR OTHER <br />DEVICES SHALL NOT EXCEED NUMBER OF BEDROOMS. ELECTRICAL BOXES MUST BE <br />SERVED BY A DIMMER, VACANCY SENSOR OR FAN SPEED CONTROL. CENC 150 (k) 1B <br />6 <br />ELECTRONIC BALLASTS ARE REQUIRED FOR ALL LAMPS RATED 13 WATTS OR GREATER. <br />7 <br />ALL INSTALLED LUMINAIRES SHALL BE HIGH-EFFICACY IN ACCORDANCE WITH CENC TABLE <br />150.0-A. (CENC 150 (k) 1A). <br />8 <br />RECESSED LUMINAIRIES IN CEILINGS SHALL BE APPROVED FOR ZERO-CLEARANCE CONTACT <br />(IC) & CERTIFIED AIRTIGHT, SHALL NOT CONTAIN SCREW BASED SOCKETS, AND SHALL BE <br />SEALED WITH GASKET OR CAULK BETWEEN HOUSING AND CEILING, AND SHALL BE JA8 <br />COMPLIANT, PER CENC 150.0 (k) 1C <br />9 <br />DIMMERS OR VACANCY SENSORS SHALL CONTROL ALL LUMINAIRES REQUIRED TO HAVE JA8 <br />COMPLIANT LIGHT SOURCES - CENC 150 (k) 2K). <br />a. LIGHTING IN CLOSETS LESS THAN 70 SQ.FT. ARE NOT REQUIRED TO BE JA8 COMPLIANT - <br />CENC 150(k) 2, k, EX. 1 <br />b.RECESSED LIGHT FIXTURES IN HALLWAYS ARE NOT REQUIRED TO BE JA8 COMPLIANT - <br />CENC 150 (k) 2K, EX. 2 <br />10 <br />AT LEAST ONE LUMINAIRE IN BATHROOMS, GARAGES, LAUNDRY ROOMS AND UTILITY ROOMS <br />SHALL BE HIGH EFFICACY AND CONTROLLED BY VACANCY SENSORS (CENC 150 (k) 2J). <br />11 <br />UNDERCABINET LIGHTING SHALL BE SWITCHED SEPARATELY FROM OTHER LIGHTING <br />SYSTEMS. (CENC 150 (k) 2L). <br />12 <br />EXHAUST FANS SHALL BE SWITCHED SEPARATELY FROM LIGHTING SYSTEM. (OR SEE <br />EXCEPTION - CENC 150 (k) 2B.) <br />13 <br />14 <br />ALL KITCHEN, BATHROOM, LAUNDRY ROOM, GARAGE AND EXTERIOR RECEPTACLES SHALL <br />BE GFCI PER CEC 210.8(A) <br />15 <br />ALL 125-VOLT, 15 AND 20 AMPERE DWELLING UNIT RECEPTACLES SHALL BE LISTED TAMPER- <br />RESISTANT PER CEC 406.12 <br />16 <br />PROVIDE A MINIMUM OF 2-20 AMP CIRCUITS TO KITCHEN COUNTERTOPS FOR SMALL <br />APPLIANCES PER CEC 210.11 (C) (1) <br />17 <br />PROVIDE A MINIMUM OF 1-20 AMP LAUNDRY BRANCH CIRCUIT PER CEC 210.11 (C) (2) <br />18 <br />A DEDICATED 120V, 20 AMP CIRCUIT SHALL SERVE THE REQUIRED BATHROOM OUTLETS. THIS <br />CIRCUIT CANNOT SUPPLY ANY OTHER RECEPTACLES, LIGHTS, FANS, ETC. CEC 210.11 (C) (3) <br />19 <br />ALL BRANCH CIRCUITS SUPPLYING 12O-VOLT SINGLE-PHASE 15 & 20-AMPERE RECEPTACLE <br />OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, <br />LIBRARIES, DENS, BEDROOMS, SUNROOMS, REC ROOMS, CLOSETS, HALLWAYS, LAUNDRY <br />AREAS, OR SIMILAR SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT <br />INTERRUPTER(S) PER CEC 210.12(A). <br />20 <br />STRUCTURED WIRING PANELS LOCATED IN CLOTHES CLOSET SHALL NOT CONTAIN <br />OVERCURRENT DEVICES PER CEC 240.24 <br />21 <br />A 120V ELECTRIC RECEPTACLE SHALL BE LOCATED WITHIN 3FT FROM THE WATER HEATER <br />AND BE ACCESSIBLE TO THE WATER HEATER WITHOUT OBSTRUCTIONS. (CENC 150 (n)1A) <br />22 <br />23 <br />RECEPTACLES THAT ARE REQUIRED AT THE FRONT AND REAR OF THE HOME, AND ON <br />BALCONIES, DECKS & PORCHES, MUST BE WITHIN 6 FEET 6 INCHES OF GRADE (AND <br />WATERPROOF AND GFCI PROTECTED). CEC 210.52 (E) & 210.8(A) <br />EXTERIOR LIGHT FIXTURES & WEATHERPROOF OUTLETS SHALL BE INSTALLED PER CEC <br />410.10(A) & 406.9, & CENC 150.0 (k) 3 <br />EXTERIOR LIGHTING SHALL BE CONTROLLED BY MANUAL ON & OFF SWITCH THAT DOES NOT <br />OVERRIDE TO ON THE AUTOMATIC ACTIONS OF ITEMS ii OR iii BELOW. SHALL ALSO BE <br />CONTROLLED BY ONE OF THE FOLLOWING: <br />II. PHOTOCELL AND MOTION SENSOR OR <br />III. ONE OF THE FOLLOWING: <br />a. PHOTOCONTROL & AUTOMATIC TIMER <br />b. ASTRONOMICAL TIME CLOCK <br />c.RGY MANAGEMENT CONTROL SYSTEM (EMCS) AS NOTED CENC 150.0 (k) 3A <br />INTERNALLY ILLUMINATED ADDRESS SIGNS SHALL:: <br />a. COMPLY WITH CENC 140.8; or <br />b. SHALL CONSUME NO MORE THAN 5 WATTS OF POWER AS DETERMINED ACCORDING <br />TO CENC 130.0 ( c) <br />24 SMOKE ALARMS SHALL BE INTERCONNECTED W/ BATTERY BACKUP OR EMERGENCY <br />ELECTRICAL SYSTEM CRC R314.4 <br />25 <br />SMOKE ALARMS SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS: CRC R314.3 & R314.3.3 <br />a. IN EACH SLEEPING ROOM <br />b.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE <br />BEDROOMS <br />c.ON EACH ADDITIONAL STORY <br />LOCATION REQUIREMENTS: <br />d.MIN. 3 FT. FROM BATHROOMS WITH TUBS OR SHOWERS. <br />e. MIN. 20 FT. FROM PERMANENTLY INSTALLED COOKING e) APPLIANCES. OR SEE <br />EXCEPTIONS NFPA 29.8.3.4 WHEN UNABLE TO ACHIEVE DISTANCE REQUIRED. <br />f.MIN. 3 FT. FROM TIP OF SUSPENDED CEILING FAN BLADE. <br />g.WITHIN 12 IN. VERTICALLY FROM HIGHEST POINT OF SLOPED OR COFFERED CEILINGS. <br />h.3 FT. HORIZONTAL PATH FROM THE SUPPLY REGISTERS OF A FORCED AIR HEATING OR <br />COOLING SYSTEM AND SHALL BE INSTALLED OUTSIDE OF THE DIRECT AIRFLOW FROM THOSE <br />REGISTERS. <br />26 <br />CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: CRC <br />R315.3 <br />a.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE <br />BEDROOMS <br />b.ON EVERY OCCUPIABLE LEVEL, INCLUDING BASEMENTS c IN BEDROOMS CONTAINING A <br />FUEL-BURNING APPLIANCE (I.E. FIREPLACE) <br />** COMBINATION SMOKE AND CARBON MONOXIDE ALARMS SHALL BE PERMITTED IN LIEU <br />OF SMOKE ALARMS OR CO2 ALARMS CRC R314.5, R314.7.4, & R315.4 <br />31 <br />COMBINATION SMOKE AND CARBON MONOXIDE DETECTORS SHALL BE INTERCONNECTED <br />AND RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING, OR FROM A BATTERY <br />BACKUP WHEN PRIMARY POWER IS INTERRUPTED (CRC R314 AND R315) <br />32 <br />TWO OR MORE SMALL APPLIANCE BRANCH CIRCUITS ARE REQUIRED FOR THE KITCHEN AND <br />ARE LIMITED TO SUPPLYING WALL AND COUNTER SPACE OUTLETS FOR THE KITCHEN, <br />PANTRY, BREAKFAST ROOM, DINING ROOM, OR SIMILAR AREAS. THESE CIRCUITS CANNOT <br />SERVE OUTSIDE PLUGS, RANGE HOOD, DISPOSALS, DISHWASHERS OR MICROWAVES - ONLY <br />THE REQUIRED COUNTERTOP/WALL OUTLETS INCLUDING THE REFRIGERATOR (CEC 210-11(C) & <br />210-52(B)) <br />FAN/LIGHTS LOCATED WITHIN 3FT HORIZONTALLY AND 8FT VERTICALLY OF THE BATHTUB RIM <br />OR SHOWER STALL THRESHOLD SHALL BE LISTED FOR A DAMP OR WET LOCATION ARE <br />SUBJECT TO SHOWER SPRAY. (PER CEC 410.10 (D) ) <br />COMBINATION SMOKE AND CARBON MONOXIDE ALARMS SHALL BE PERMITTED IN LIEU OF <br />SMOKE ALARMS OR CO2 ALARMS (CRC R314.5, R314.7.4, & R315.4) <br />27 <br />ATLEAST ONE 120-VOLT, 20-AMPERE BRANCH CIRCUIT SHALL BE INSTALLED TO SUPPLY <br />RECEPTACLE OUTLETS IN ATTACHED GARAGES AND IN DETACHED GARAGES WITH ELECTRIC <br />POWER. THIS CIRCUIT SHALL HAVE NO OTHER OUTLETS. EXCEPTION: CIRCUIT SHALL BE <br />PERMITTED TO SUPPLY READILY ACCESSIBLE OUTDOOR RECEPTACLE OUTLETS (CEC 210.11) <br />MECHANICAL NOTES <br />CODE REFERENCES BASED ON <br />2022 CALIFORNIA MECHANICAL CODE <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />a. <br />b. <br />9. <br />10. <br />11. <br />12. <br />13. <br />14. <br />15. <br />16. <br />17. <br />ROOMS CONTAINING TUBS, SHOWERS OR SIMILAR BATHING <br />FIXTURES SHALL BE MECHANICALLY VENTILATED IN <br />ACCORDANCE WITH CMC APPDX E 605.2 & CRC R303.3.1 <br />INCLUDING ACCESSIBLE HUMIDISTAT CONTROL (CGBC 4.506.1) <br />ALL EXHAUST DUCTS SHALL HAVE SMOOTH INTERIOR SURFACE <br />AND TERMINATE OUTSIDE THE BUILDING AND SHALL BE <br />EQUIPPED WITH A BACKDRAFT DAMPER. (CMC 504.1) <br />TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS (i.e., <br />CLOTHES DRYER VENTS, BATH AND UTILITY FANS, ETC.) SHALL <br />BE A MINIMUM OF 3 FEET FROM PROPERTY LINES OR ANY <br />OPENINGS INTO THE BUILDING. PER CMC 502.2.1 <br />DRYER VENT OUTLET SHALL BE MIN. 5 FT. FROM AIR <br />CONDITIONING CONDENSER (CENC 150 (h) 3.A) <br />PROVIDE MIN. 4" DIA. SMOOTH METAL DRYER VENT W/ <br />BACKDRAFT DAMPER TO EXTERIOR. VENT RUN SHALL <br />COMPLY WITH MNFR.'S SPECS. AND CMC 504.4.2 & 908. <br />LENGTH OF RUN MAY EXCEED 14'-0" IF PERMITTED BY DRYER <br />MNFR.'S INSTALLATION INSTRUCTIONS AND APPROVED BY THE <br />AUTHORITY HAVING JURISDICTION. <br />WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A <br />CLOTHES DRYER, AN OPENING OF NOT LESS THAN 100 <br />SQUARE INCHES FOR MAKEUP AIR SHALL BE PROVIDED IN THE <br />DOOR OR BY OTHER APPROVED MEANS PER CMC 504.4.1 <br />WHOLE BUILDING VENTILATION SHALL BE PROVIDED AND <br />CONFIRMED THRU FIELD VERIFICATION & DIAGNOSTIC TESTING, <br />PER CENC 150 (o) <br />CALCULATION: 1 CFM PER 100 SF. FLOOR AREA PLUS <br />NUMBER OF BEDROOMS PLUS ONE, MULTIPLIED BY 7.5 CFM. <br />EXAMPLE: 1500 SF HOME W/ 3 BEDRMS = 15 CFM BLDG + <br />30 CFM PER OCCUPANT = 45 CFM REQUIRED. <br />HOUSEHOLD COOKING APPLIANCES SHALL HAVE A VERTICAL <br />CLEARANCE ABOVE THE COOKING TOP OF NOT LESS THAN <br />30INCHES TO COMBUSTIBLE MATERIAL OR METAL CABINETS <br />(CMC 920.3.2) <br />CLOTHES DRYER EXHAUST DUCT SHALL NOT BE CONNECTED <br />TO A VENT CONNECTOR, GAS VENT OR CHIMNEY AND SHALL <br />NOT TERMINATE INTO A CRAWL SPACE, ATTIC OR OTHER <br />CONCEALED SPACE. <br />EXHAUST DUCTS SHALL NOT BE ASSEMBLED WITH SCREWS OR <br />OTHER FASTENING MEANS THAT EXTEND INTO THE DUCT AND <br />THAT ARE CAPABLE OF CATHING LINT, AND THAT REDUCE THE <br />EFFICIENCY OF THE EXHAUST SYSTEM. <br />SCREENS SHALL NOT BE INSTALLED AT THE DUCT <br />TERMINATION. <br />WHERE JOINING OF DUCTS, THE MALE END SHALL BE INSERTED <br />IN THE DIRECTION OF AIRFLOW (CMC 504.4) <br />DOMESTIC CLOTHES DRYER MOISTURE EXHAUST DUCTS SHALL <br />NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL <br />LENGTH OF 14FT, INCLUDING TWO 90-DEGREE ELBOWS. A <br />LENGTH OF 2FT SHALL BE DEDUCTED FOR EACH 90-DEGREE <br />ELBOW IN EXCESS OF TWO (CMC 504.4.2.1) <br />CLOTHES WASHER STANDPIPES SHALL BE 2INCH IN DIAMETER. <br />NO TRAP FOR A CLOTHES WASHER STANDPIPE RECEPTOR <br />SHALL BE INSTALLED BELOW THE FLOOR, BUT SHALL BE <br />ROUGHED IN NOT LESS THAN 6INCHES AND NOT MORE THAN <br />18INCHES ABOVE THE FLOOR. (CPC 804.1) <br />NO STANDPIPE RECEPTOR FOR A CLOTHES WASHER SHALL <br />EXTEND MORE THAN 30INCHES AND NOT LESS THAN 18INCHES <br />ABOVE ITS TRAP. (CPC 804.1) <br />SHEET NO.: <br />SHEET TITLE: <br />DATE: <br />DR <br />A <br />W <br />I <br />N <br />G <br />S <br /> <br />P <br />R <br />O <br />V <br />I <br />D <br />E <br />D <br /> <br />B <br />Y <br />: <br />OC <br />- <br />A <br />D <br />U <br />24 <br />8 <br />8 <br />1 <br /> <br />A <br />L <br />I <br />C <br />I <br />A <br /> <br />P <br />K <br />W <br />Y <br />, <br /> <br />S <br />T <br />E <br />. <br /> <br />E- <br />2 <br />2 <br />2 <br />, <br /> <br />L <br />A <br />G <br />U <br />N <br />A <br /> <br />H <br />I <br />L <br />L <br />S <br />94 <br />9 <br />- <br />4 <br />1 <br />4 <br />- <br />8 <br />7 <br />9 <br />9 <br />A5 <br />PROPOSED <br />ELECTRICAL <br />PLAN <br />2025/01/20 <br />10 <br />1 <br />2 <br /> <br />W <br /> <br />3 <br />R <br />D <br /> <br />S <br />T <br /> <br />U <br />N <br />I <br />T <br /># <br />1 <br />& <br /># <br />2 <br /> <br />( <br />D <br />U <br />P <br />L <br />E <br />X <br />' <br />S <br />) <br />10 <br />1 <br />4 <br /> <br />W <br /> <br />3 <br />R <br />D <br /> <br />S <br />T <br /> <br />U <br />N <br />I <br />T <br /># <br />1 <br />& <br />U <br />N <br />I <br />T <br /># <br />2 <br /> <br />( <br />A <br />D <br />U <br />' <br />S <br />) <br />NE <br />W <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br />AD <br />U <br />SCALE: 1/4" = 1'-0"1 PROPOSED ELECTRICAL PLAN N <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br /> <br />T <br />A <br />B <br />L <br />E <br />No <br />. <br />DA <br />T <br />E <br />RE <br />V <br />I <br />S <br />E <br />D <br /> <br />B <br />Y <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />HISTORIC - 1012 W Third St & <br />1014 W Third St Unit 1 & Unit 2 <br />4/14/2025