Laserfiche WebLink
WOOD NOTES <br />CONCRETE NOTES <br />WOOD NOTES (cont.)GENERAL NOTES STRUCTURAL STEEL NOTES MASONRY NOTES <br />REINFORCING STEEL NOTES <br />SIMPLE SPANS <br />CANTILEVERS <br />24F-V4 <br />24F-V8 <br />USECOMBINATION NO. <br />24/0 <br />48/24 <br />24/0 <br />OSB <br />APA <br />OSB (U.N.O.) <br />ROOF SHEATING <br />FLOOR SHEATHING <br />SHEAR PANEL <br />PANEL <br />INDENTIFICATION INDEXGRADEUSE <br />A. <br />B. <br />C. <br />D. <br />E. <br />EMBEDDED AT LEAST 7" INTO CONCRETE OR MASONRY. <br />SPACED NOT MORE THAN 6' APART. <br />PLACED A MIN. OF 4" AND A MAX. OF 12" FROM EACH END. A MINIMUM OF <br />TWO BOLTS PER PIECE. <br />SIZE AND SPACED AS SHOWN ON THE DRAWINGS. <br />GRADEMEMBERS <br />CONSTRUCTION <br /># 2 <br /># 2 <br /># 1 <br /># 1 <br /># 1 <br />MATCH WALL MEMBERS <br />SAWN WOOD MEMBERS SHALL BE DOUGLAS FIR-LARCH (U.N.O.), CONFORM TO <br />THE "CALIFORNIA BUILDING CODE" (CBC) SEC. 2303, and NDS 2018 AND SHALL BE <br />GRADE MARKED BY AN ACCREDITATION BODY THAT COMPLIES WITH DOC PS 20 <br />OR EQUIVALENT. <br />WOOD GRADES, U.N.O., SHALL BE AS FOLLOWS: <br />ALL WOOD THAT REST ON EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8" <br />FROM EXPOSED EARTH, ALL WOOD ATTACHED DIRECTLY TO INTERIOR OR <br />EXTERIOR MASONRY OR CONCRETE WALLS BELOW GRADE, AND ALL WOOD <br />SLEEPERS AND SILLS ON CONCRETE THAT IS IN DIRECT CONTACT WITH EARTH <br />SHALL BE PRESERVATIVE-TREATED DOUGLAS FIR. <br />ALL SILLS OR PLATES BEARING ON CONCRETE OR MASONRY SHALL HAVE ANCHOR <br />BOLTS: <br />WOOD STRUCTURAL PANELS SHALL CONFORM TO THE "CALIFORNIA BUILDING <br />CODE" (CBC) SEC. 2303, AND SHALL CONFORM TO THE REQUIREMENTS FOR THEIR <br />TYPE IN DOC PS 1 OR PS2. EACH PANEL SHALL BE IDENTIFIED FOR GRADE AND <br />GLUE TYPE BY THE TRADEMARKS OF AN APPROVED TESTING AND GRADING <br />AGENCY. WOOD STRUCTURAL PANELS THAT ARE PERMANENTLY EXPOSED IN <br />OUTDOOR APPLICATIONS SAHLL BE OF EXTERIOR TYPE (U.N.O.). ALL WOOD <br />STRUCTURAL PANELS SHALL BE OF THE FOLLOWING GRADES AND PANEL <br />INDENTIFICATION INDEXES (U.N.O. ON DRAWINGS): <br />GLUED-LAMINATED TIMBERS SHALL BE MANUFACTURED AND IDENTIFIED AS <br />REQUIRED IN AITC A190.1 AND ASTM D 3737, USING DOUGLAS FIR INDUSTRIAL <br />APPEARANCE GRADE WOOD AND EXTERIOR GLUE WITH INTENDED DRY USE <br />CONDITION AND USE SHALL BE AS FOLLOWS: <br />FRAMING ANCHORS, POST CAPS, COLUMN BASES, AND OTHER CONNECTORS <br />SPECIFIED ON DRAWINGS SHALL BE AS MANUFACTURED BY "SIMPSON COMPANY" <br />OR AN ENGINEER- APPROVED EQUAL. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />BARS, PLATES, UNHEADED BOLTS, WASHERS AND DRIFT BOLTS SHALL CONFORM TO THE <br />REQUIREMENTS OF ASTM A36. <br />BOLTS SHALL CONFORM TO ASTM A307. BOLTS IN PRESSURE TREATED WOOD SHALL BE <br />HOT DIPPED ZINC-COATED GALVANIZED STEEL PER ASTM A 153 OR MECHANICALLY <br />DEPOSITED ZINC COATING WITH WEIGHTS PER ASTM B 695, CLASS 55. <br />NUTS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A563, GRADE A. <br />ALL BOLT HEADS, NUTS, AND LAG SCREWS BEARING ON WOOD SHALL HAVE CUT <br />WASHERS UNLESS NOTED. <br />BOLT HOLES SHALL BE DRILLED A MAXIMUM OF 1/16" LARGER THAN THE NOMINAL BOLT <br />DIAMETER. BOLT HOLES SHALL BE ACCURATELY ALIGNED AND NOT FORCIBLY DRIVEN. <br />SPECIAL CONNECTORS FOR CONNECTING WOOD OR GLUED LAMINATED TIMBER SHALL <br />BE FABRICATED FROM STEEL CONFORMING TO ASTM A36. WELDS SHALL CONFORM TO <br />THE REQUIREMENTS OF AWS D1.1-15. <br />8. <br />9. <br />10. <br />11. <br />12. <br />13. <br />FOR SHANK: <br />FOR THREADED PORTION: <br />SAME DIAMETER AND LENGTH AS UNTHREADED <br />SHANK. <br />60% TO 75% OF SHANK DIAMETER & LENGTH EQUAL <br />TO THE THREADED PORTION. <br />BN = <br />EN = <br />FN = <br />NAILING AT DIAPHRAGM BOUNDARIES, CONTINUOUS PANEL <br />EDGES, AND AT EDGES OF OPENING. <br />EDGE NAILING <br />FIELD NAILING <br />SILL PLATE SHALL BE 3x6 P.T. D.F. <br />ALL STUDS AND BLOCKING AT PANEL EDGES SHALL BE 4x6. <br />ALL OTHER INTERMEDIATE STUDS SHALL BE 3x6 @ 16"o.c. <br />END POSTS SHALL BE AS SPECIFIED ON THE DRAWINGS. <br />BOTH VERTICAL AND HORIZONTAL INTERIOR PANEL JOINTS <br />ON OPPOSITE SIDES OF THE WALL SHALL BE STAGGERED. <br />THE PLYWOOD ON ONE SIDE MUST BE NAILED BEFORE THE FRAME INSPECTION. <br />THE PLYWOOD ON THE OTHER SIDE <br />MUST BE INSTALLED AND INSPECTED PRIOR TO INSTALLATION <br />OF WALL SURFACE COVERING. <br />NO PENETRATIONS OR NOTCHES ARE PERMITSED OTHER THAN THOSE SHOWN <br />ON THE STRUCTURAL DRAWINGS. <br />A. <br />B. <br />C. <br />D. <br />E. <br />F. <br />G. <br />DIAPHRAGM NAILING SHALL CONFORM TO CBC WITH NOMENCLATURE DEFINED AS <br />FOLLOWS: <br />WHERE DIAPHRAGM BLOCKING IS SPECIFIED, USE 2 X 4 FLAT BLOCKING (WITH "Z" <br />CLIPS). (U.N.O.) <br />SIMPLE SPAN WOOD MEMBERS, NOT SHOP CAMBERED, SHALL BE ERECTED WITH THE <br />NATURAL CAMBER UP. FOR CANTILEVERED WOOD MEMBERS, CONSULT WITH <br />ENGINEER. <br />LEAD HOLES FOR LAG SCREWS IN WOOD SHALL BE BORED AS FOLLOWS: <br />SPECIAL PROVISIONS FOR SHEAR WALLS WITH PLYWOOD ON BOTH SIDES: WHERE <br />SPECIFICALLY INDICATED ON PLANS <br />PROVIDE DOUBLE STUD TO SUPPORT ALL BEAMS UNLESS POSTS ARE SPECIFIED. <br />DOUBLE BLOCK UNDER ALL POSTS. <br />DOUBLE JOIST UNDER ALL PARALLEL PARTITIONS U.N.O. <br />TOP PLATES OF ALL WOOD STUD WALLS SHALL BE 2-2 X (SAME WIDTH AS STUDS), LAP <br />48" (MIN.), WITH AT LEAST 36-16d NAILS AT EACH SIDE OF LAP AND NOT MORE THAN 12" <br />BETWEEN. <br />CUTTING, NOTCHING, OR DRILLING OF BEAMS OR JOISTS SHALL BE PERMITSED ONLY AS <br />DETAILED OR APPROVED BY THE ENGINEER. <br />MOISTURE CONTENT OF WOOD AT TIME OF PLACEMENT SHALL NOT EXCEED 19%. <br />PROVIDE 'MSTC28' STRAPS ACROSS ALL DISCONTINUOUS TOP PLATES. <br />THE NUMBER AND SIZE OF FASTENERS CONNECTING WOOD MEMBERS SHALL NOT BE <br />LESS THAN THE FOLLOWING TABLE. <br />14. <br />15. <br />16. <br />17. <br />18. <br />19. <br />20. <br />21. <br />22. <br />23. <br />24. <br />25. <br />26. <br />ASTM A992, Fy= 50ksi <br />ASTM A500 GRADE B, Fy= 46ksi <br />ASTM A500, GRADE B, Fy= 42ksi <br />ASTM A53, GRADE B, Fy= 35ksi <br />ASTM A36, Fy = 36 ksi <br />GRADE 40 - # 3 AND SMALLER <br />GRADE 60 - # 4 AND LARGER <br />BAR REINFORCEMENT SHALL CONFORM TO THE REQUIREMENTS OF ASTM A615. THE <br />FOLLOWING GRADES SHALL BE USED: <br />DETAILS OF REINFORCEMENT SHALL CONFORM TO THE REQUIREMENTS OF ACI 318-19 CH. <br />7 AND OTHER SECTIONS ACCORDING TO APPLIC. <br />LAPS AT BAR SPLICES IN CONC. CONSTRUCTION SHALL BE AS FOLLOWS: <br />LAPS AT BAR SPLICES IN MASONRY CONSTRUCTION SHALL BE 48 BAR DIAMETERS BUT NOT <br />LESS THAN 2'-0". <br />VERTICAL REINFORCEMENT SHALL BE TIED OR OTHERWISE FIXED IN POSITION AT THE TOP <br />AND BOTTOM AND AT INTERMEDIATE LOCATIONS, SPACED NOT GREATER THAN 48" O.C.. <br />WELDED STEEL WIRE FABRIC REINFORCEMENT SHALL CONFORM TO ASTM A185. 12" LAPS <br />OF WELDED STEEL WIRE FABRIC AT SPLICES ARE REQ'D. <br />WALLS, PILASTERS, AND COLUMNS SHALL BE DOWELED TO THE SUPPORTING FOOTINGS <br />WITH REINFORCEMENT OF THE SAME SIZE, GRADE AND AT THE SAME SPACING AS THE <br />VERTICAL REINFORCEMENT IN THE WALLS, PILASTERS, OR COLUMNS (U.N.O). <br />BAR SUPPORTS SHALL BE PROVIDED IN ACCORDANCE WITH THE PROVISIONS OF "BAR <br />SUPPORT SPECIFICATIONS" AS CONTAINED IN THE LATEST EDITION OF THE "MANUAL OF <br />STANDARD PRACTICE" BY THE CONCRETE REINFORCING STEEL INSTITUTE (CRSI). <br />REINFORCING STEEL DETAILING, BENDING AND PLACING SHALL BE IN ACCORDANCE WITH <br />THE CONCRETE REINFORCING STEEL INSTITUTE "MANUAL OF STANDARD PRACTICE", <br />LATEST EDITION. <br />ALL REINFORCEMENT SHALL BE SECURELY TIED IN PLACE BEFORE PLACING CONCRETE <br />OR GROUT. <br />WELDING OF REINFORCING BARS SHALL CONFORM TO "STRUCTURAL WELDING <br />CODE-REINFORCING STEEL," ANSI/AWS D1.4 OF THE A.W.S. <br />WELDING OF ALL REINFORCING STEEL TO STRUCTURAL STEEL SHALL BE LIMITED TO <br />THOSE AREAS SPECIFICALLY SHOWN ON THE PLANS. ANY OTHER WELDING SHALL <br />REQUIRE THE APPROVAL OF THE GOVERNING AGENCY, FIELD INSPECTOR, AND <br />STRUCTURAL ENGINEER. <br />WELDING OF CROSSING BARS AND TACK WELDING OF REINFORCEMENT SHALL NOT BE <br />PERMITSED. <br />ALL WELDS SHALL, IN ADDITION, TO ALL THE SPECIFICATIONS LISTED ABOVE, COMPLY <br />WITH THE REQUIREMENTS OF THE 14th EDITION OF THE "STEEL CONSTRUCTION MANUAL" <br />AS PUBLISHED BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />12. <br />13. <br />14. <br />(CLASS B) <br />f'c = 3000 <br />21 <br />29 <br />25 <br />33 <br />f'c = 3000 <br />27 <br />38 <br />33 <br />f'c = 2500 <br />30 <br />40 <br />35 <br />(CLASS B)TOP BARS <br /># 7 <br /># 6 <br /># 5 <br />BAR SIZE <br /># 8 4345 <br />OTHER THAN TOP BARS <br />32 <br />28 <br />f'c = 2500 <br />24 <br />36 <br /># 6 AND LARGER BAR <br /> # 5 BARS, 5/8 INCH WIRE, AND SMALLER <br />MIN. CVR. <br />(INCHES)LOCATION: <br />STRENGTH:CONVENTIONAL FOUNDATIONS: <br />A. CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH <br />B. FORMED SURFACES EXPOSED TO EARTH OR WEATHER: <br />3" <br />2" <br />1 12" <br />2500 <br />2500 <br />2500 <br />2500 <br />SLAB ON GRADE <br />SLAB ON GRADE-GARAGE <br />FOOTINGS <br />GRADE BEAM / CAISSON <br />CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ACI 318-19 CHAPTER 5. THE MINIMUM 28-DAY <br />CYLINDER STRENGTH SHALL BE AS FOLLOWS: <br />WHERE CONCRETE STRENGTH IS GREATER THAN 2500 PSI, CYLINDER TESTS ARE REQUIRED PER ACI <br />318-19 5.6.3.3. <br />PORTLAND CEMENT SHALL CONFORM TO THE REQUIREMENTS OF ASTM C150, TYPE V. MAXIMUM <br />WATER-CEMENT RATIO = 0.45 <br />AGGREGATES SHALL CONFORM TO THE REQUIREMENTS OF ASTM C33 <br />FOR NORMAL WEIGHT CONCRETE AND ASTM C330 FOR LIGHTWEIGHT CONCRETE. <br />ADMIXTURES SHALL BE USED IN ACCORDANCES WITH THE MANUFACTURER'S RECOMMENDATIONS AND <br />APPROVED BY THE ENGINEER OF RECORD. <br />READY-MIX CONCRETE SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH THE REQUIREMENTS <br />OF "STANDARD SPECIFICATION FOR READY-MIXED CONCRETE" ASTM C94. <br />MINIMUM CONCRETE COVER (IN INCHES) FOR REINFORCING STEEL IN NON-PRESTRESSED <br />CAST-IN-PLACE CONCRETE SHALL BE AS FOLLOWS, U.N.O: <br />ALL SLEEVES THROUGH BEAMS, GIRDERS AND FOUNDATION WALLS SHALL BE INSTALLED AND <br />SECURED IN POSITION PRIOR TO PLACING CONCRETE. EXCEPT AS SHOWN ON STRUCTURAL <br />DRAWINGS, SLEEVING SHALL NOT BE PERMITSED UNLESS APPROVED BY THE DESIGNER AND <br />STRUCTURAL ENGINEER. <br />SLEEVES, PIPES, OR CONDUITS SHALL NOT BE PLACED THROUGH CONTINUOUS OR SPREAD FOOTINGS, <br />GRADE BEAMS, PILE CAPS, OR TIE BEAMS, UNLESS SPECIFICALLY DETAILED BY THE ENGINEER. <br />CONDUIT SHALL NOT BE PLACED IN ANY CONCRETE SLAB LESS THAN <br />3-1/2 INCHES THICK. IF CONDUIT IS PLACED IN CONCRETE SLAB, ITS OUTSIDE DIAMETER SHALL NOT <br />BE GREATER THAN 1/3 OF THE SLAB THICKNESS. THE MINIMUM CLEAR DISTANCE BETWEEN CONDUITS <br />SHALL <br />BE 3 INCHES. <br />ALL EXPOSED CORNERS SHALL BE CHAMFERED 3/4 INCH, U.N.O. <br />REFER TO ARCHITECTURAL DRAWINGS FOR MOLDS, GROOVES, <br />ORNAMENTS, CLIPS, OR GROUNDS REQUIRED TO BE CAST IN THE CONCRETE AND FOR EXTENT OF <br />DEPRESSIONS, CURBS, AND RAMPS. <br />ALL VERTICAL SURFACES OF CONCRETE ABOVE FINISHED GRADE <br />SHALL BE FORMED. <br />REFERENCE ARCH. DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS DUE TO <br />ARCHITECTURAL C.I.P. CONCRETE. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />12. <br />13. <br />14. <br />PSI <br />PSI <br />PSI <br />PSI <br />ALL CONSTRUCTION, INCLUDING MATERIAL AND WORKMANSHIP, SHALL CONFORM TO <br />THE PROVISIONS OF THE 2022 EDITION OF THE "CALIFORNIA BUILDING CODE" (CBC) WITH <br />THE GOVERNING AGENCY AMENDMENTS, AND STANDARDS REFERENCED THEREIN. <br />WHERE EVER CODE OR CALIFORNIA BUILDING CODE (CBC) IS REFERENCED IN THE <br />FOLLOWING GENERAL NOTES OR OTHER NOTE SECTIONS, IT SHALL IMPLY THE CBC <br />CODE WITH GOVERNING AGENCY AMMENDMENTS. <br />ALL ASTM STANDARDS LISTED HEREIN, SHALL BE CURRENT AND COMPLIANT TO 2022 <br />CBC, CHAPTER 35. <br />THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS <br />BEFORE STARTING WORK. THE DESIGNER AND STRUCTURAL ENGINEER SHALL <br />IMMEDIATELY BE NOTIFIED, IN WRITING, OF ANY DISCREPANCIES. <br />ALL OMISSIONS AND/OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE <br />WORKING DRAWINGS AND SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF <br />THE FIELD INSPECTOR, AND A SOLUTION GIVEN BY, THE DESIGNER AND STRUCTURAL <br />ENGINEER PRIOR TO PROCEEDING WITH ANY WORK AFFECTED BY THE CONFLICT OR <br />OMISSION. <br />IN CASE OF CONFLICT, NOTES AND DETAILS OF THESE STRUCTURAL DRAWINGS SHALL <br />TAKE PRECEDENCE OVER THE "GENERAL NOTES" AND/OR "STANDARD DETAILS". <br />TYPICAL DETAILS SHALL BE USED WHENEVER APPLICABLE. <br />IF A SPECIFIC DETAIL IS NOT SHOWN FOR ANY PART OF THE WORK, THE CONSTRUCTION <br />SHALL BE THE SAME AS FOR SIMILAR WORK. <br />WORKING DIMENSIONS SHALL NOT BE SCALED FROM PLANS, SECTIONS OR DETAILS ON <br />THESE STRUCTURAL DRAWINGS. <br />THE CONTRACTOR SHALL PROVIDE AND MAINTAIN ADEQUATE ERECTION SHORING AND <br />BRACING AS REQUIRED FOR STABILITY OF THE STRUCTURE DURING ALL PHASES OF <br />CONSTRUCTION. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE AND DO NOT <br />INDICATE THE METHOD OF CONSTRUCTION. <br />PIPES, DUCTS, SLEEVES, OPENINGS, POCKETS, CHASES, BLOCK-OUTS, ETC., SHALL NOT <br />BE PLACED IN SLABS, BEAMS, GIRDERS, COLUMNS, WALLS, FOUNDATIONS, ETC., NOR <br />SHALL ANY STRUCTURAL MEMBER BE CUT FOR SUCH ITEMS, UNLESS SPECIFICALLY <br />DETAILED ON THESE STRUCTURAL DRAWINGS. (IF ANY PIPES, DUCTS, ETC., DO OCCUR, <br />THAT ARE NOT SHOWN ON THESE STRUCTURAL DRAWINGS, THE DESIGNER AND <br />STRUCTURAL ENGINEER SHALL BE NOTIFIED.) SEE PARAGRAPH 4, ABOVE. <br />ANCHOR BOLTS OR INSERTS FOR EQUIPMENT ANCHORAGE OR INSTALLATION SHALL BE <br />DESIGNED FOR SEISMIC CATEGORY D BY A CIVIL ENGINEER OR STRUCTURAL ENGINEER <br />REGISTERED IN THE STATE OF CALIFORNIA AND SHALL BE SHOWN ON THE MECHANICAL <br />OR ELECTRICAL SHOP DRAWINGS. <br />THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE <br />CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING <br />SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL APPLY <br />CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE CONTRACTOR <br />SHALL DEFEND, INDEMNIFY, AND HOLD THE STRUCTURAL ENGINEER FREE AND <br />HARMLESS FROM ALL CLAIMS, DEMANDS AND ALL LIABIBLITY, REAL OR ALLEGED, IN <br />CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPT FOR <br />LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE STRUCTURAL ENGINEER. <br />IF ANY SUBSTITUTION IS PROPOSED BY THE CONTRACTOR, NEW CALCULATIONS MAY <br />HAVE TO BE PREPARED, THE DETAILS MAY HAVE TO BE ALTERED, AND NEW DRAWINGS <br />MAY HAVE TO BE SUBMITSED TO THE BUILDING DEPARTMENT. THE CONTRACTOR SHALL <br />PAY THE STRUCTURAL ENGINEER'S FEES TO ALTER THE APPROVED PLANS. THE <br />CONTRACTOR SHALL ALSO PROCESS THE REVISED PLANS REFLECTING ALL <br />SUBSTITUTIONS THROUGH THE APPROPRIATE OFFICE OF ALL GOVERNING AGENCIES. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />12. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />MASONRY UNITS SHALL CONFORM TO ASTM C90 HOLLOW CORE, <br />NORMAL WEIGHT, f'm= 1500 psi (U.N.O.). <br />ALL UNITS SHALL BE SAMPLED AND TESTED IN ACCORDANCE WITH ASTM C140. <br />MORTAR SHALL BE TYPE 'S' AND CONFORM TO ASTM C270 AND TABLE SC-1 AND SC-2 OF TMS 402-16. THE <br />MINIMUM STRENGTH SHALL BE 1,800 psi AT 28 DAYS. THE BED JOINTS SHALL NOT EXCEED }" THICK. <br />GROUT SHALL CONFORM WITH ARTICLE 2.2 OF TMS 402-16. <br />THE COMPRESSIVE STRENGTH OF GROUT SHALL BE DETERMINED IN ACCORDANCE WITH ASTM C1019. <br />WHEN THE GROUT CONFORMS TO ASTM C476, THE GROUT SHALL BE SPECIFIED BY PROPORTION <br />REQUIRMENTS OR PROPERTY REQUIREMENTS. THE MINUMUM STRENGTH SHALL BE 2,000 psi AT 28 DAYS. <br />PORTLAND CEMENT SHALL CONFORM TO THE REQUIREMENTS OF ASTM C150. <br />BLENDED CEMENT SHALL CONFORM TO THE REQUIREMENTS OF ASTM C595. <br />MASONRY CEMENT SHALL CONFORM TO THE REQUIREMENTS OF ASTM C91. <br />MORTAR CEMENT SHALL CONFORM TO THE REQUIREMENTS OF ASTM C1329. <br />COARSE AGGREGATE SHALL CONFORM TO ASTM C404. <br />COARSE AGGREGATE SHALL BE PEA GRAVEL. <br />FINE AGGREGATE SHALL CONFORM TO ASTM C144. <br />LIME SHALL BE HYDRATED LIME AND CONFORM TO ASTM C207, TYPE S. <br />ADMIXTURES SHALL BE USED IN ACCORDANCES WITH THE MANUFACTURER'S RECOMMENDATIONS AND <br />APPROVED BY THE ENGINEER OF RECORD. <br />SHEET INDEX: <br />GENERAL STRUCTURAL NOTESSN <br />FOUNDATION & ROOF FRAMING PLAN <br />SD2 PR <br />O <br />J <br />E <br />C <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />sheet no: <br />sheet title: <br />revisions: <br />- <br />- <br />- <br />- <br />drawn by: <br />job number: <br />AM <br />- <br />N <br />e <br />w <br /> <br />A <br />D <br />U <br />- <br />2 <br />0 <br />1 <br />0 <br /> <br />A <br />l <br />c <br />o <br /> <br />A <br />v <br />e <br />, <br /> <br />U <br />n <br />i <br />t <br /> <br />2 <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />AR24-0819 <br />DATE: 02/05/2025 <br />THESE DRAWINGS AND <br />SPECIFICATIONS, IDEAS, DESIGNS AND <br />ARRANGEMENTS ARE, AND SHALL <br />REMAIN, THE PROPERTY OF AB33R <br />ENGINEERING LLC. NO PART SHALL BE <br />COPIED, REPRODUCED OR OTHERWISE <br />USED, DIRECTLY OR INDIRECTLY, IN <br />WHOLE OR IN PART, IN CONNECTION <br />WITH ANY OTHER WORK OR PROJECT <br />WITHOUT THE WRITTEN CONSENT OF <br />AB33R ENGINEERING. VISUAL CONTACT <br />WITH THESE DRAWINGS AND/OR <br />SPECIFICATIONS SHALL CONSTITUTE A <br />PRIMA FACIE EVIDENCE OF <br />ACCEPTANCE OF THESE RESTRICTIONS. <br />2610 E EMBRY LN. <br />ONTARIO, CA 91762 <br />TEL: (909) 907 - 3949 <br />EMAIL: <br />ab33r.engineering@gmail.com <br />AB33R <br />ENGINEERING <br />SD1 CONSTRUCTION DETAILS <br />1. <br />2. <br />3. <br />4. <br />5. <br />THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL BE IN <br />ACCORDANCE WITH AISC 360-16. <br />ALL STRUCTURAL STEEL TO BE THE FOLLOWING: <br />W SHAPES: <br />HSS SHAPES (RECTANGULAR) <br />HSS SHAPES (ROUND): <br />PIPE SHAPES: <br />ALL OTHER STEEL: <br />ALL STRUCTURAL WELDS TO BE THE FOLLOWING: <br />E70 SERIES-TYP. <br />E90 SERIES FOR A615 GRADE 60 REINFORCING BARS <br />ALL STRUCTURAL WELDING SHALL BE DONE IN AN APPROVED FABRICATING SHOP. IN <br />ABSENCE OF AN APPROVED FABRICATING SHOP, STRUCTURAL WELDING SHALL BE DONE <br />UNDER THE SUPERVISION OF A CERTIFIED SPECIAL INSPECTOR. (CBC 1705.2.2) <br />FIELD WELDING TO HAVE CONTINUOUS SPECIAL INSPECTION. <br />CONSTRUCTION DETAILS <br />SN2 <br />WALLS 2 X 4 (8'-0") <br />WALLS 2 X 4 (8'-1" TO 12'-0") <br />WALLS 2 X 6 (12'-0" to 16'-0") <br />STRUCTURAL JOISTS AND PLANKS (2x) <br />BEAMS AND STRINGERS (4x8 & WIDER) <br />POSTS AND TIMBERS <br />TOP PLATE <br />SHEAR WALL SCHEDULE NOTES <br />A35 OR LTP4 @ <br />24"o.c. <br />ANCHOR BOLT SCHED. <br />532 <br />MATERIAL AND NAILING DESCRIPTIONSYMBOL <br />2x PLATE W/ 16d @ 3"o.c. <br />2x PLATE W/ 16d @ 6"o.c. <br />2x PLATE W/ 16d @ 4"o.c.A35 OR LTP4 @ <br />16"o.c. <br />A35 OR LTP4 @ <br />12"o.c. <br />365 <br />8d @ 4"o.c. E.N. / 6"o.c. F.N. <br />8d @ 6"o.c. E.N. / 6"o.c. F.N. <br />1/2" OSB W/2x SILL PLATE W/ <br /> 12" DIA A.B. @ 36"o.c. <br />3x SILL PLATE W/ 58" DIA <br />A.B. @ 24"o.c. <br />1/2" OSB W/ <br />685 8d @ 3"o.c. E.N. / 6"o.c. F.N. <br />(SEE NOTE 13) <br />1/2" OSB W/ <br />ON 3x FRAMING <br />895 8d @ 2"o.c. E.N. / 6"o.c. F.N. <br />ON 3x FRAMING (SEE NOTE 13) <br />2x PLATE W/ 12" x 8" LONG LAG <br />SCREWS @ 8"o.c. INTO 4x RIM <br />JOIST/BLOCK'G. <br />A35 OR LTP4 @ <br />10"o.c. <br />1/2" OSB W/ <br />10d @ 2"o.c. E.N. / 6"o.c. F.N. <br />1/2" STRUCTURAL 1 PLYWOODW w/3x PLATE W/ 12" x 8" LONG LAG <br />SCREWS @ 6"o.c. INTO 4x RIM <br />JOIST/BLOCK'G. <br />A35 OR LTP4 @ <br />8"o.c.1217 <br />3x SILL PLATE W/ 58" DIA <br />A.B. @ 24"o.c. <br />(SEE NOTES 13)ON 3x FRAMING <br />SHEAR TRANSFER <br />RIM JOIST/BLOCKING <br />(SEE NOTE 15) <br />BOTTOM PLATESIZE & NAILING <br />(SEE NOTE 16) <br />(SEE NOTE 16) <br />(SEE NOTE 16) <br />& SILL PLATE SIZE <br />(SEE NOTE 9, 10, 11) <br />3x SILL PLATE W/ 58" DIA <br />A.B. @ 20"o.c. <br />3x SILL PLATE W/ 58" DIA <br />A.B. @ 18"o.c. <br />1 <br />2 <br />3 <br />4 <br />5 <br />(SEE NOTE 13)ON 3x FRAMING <br />MAX DESIGN SHEAR CAP. (PLF) <br />1. SHEAR PANELS SHALL BE APPLIED DIRECTLY TO STUD FRAMING. <br />2. PLYWOOD MAY BE INSTALLED EITHER HORIZONTALLY OR VERTICALLY. <br />3. ALL PLYWOOD PANEL EDGES SHALL BE BLOCKED W/ 2x BLOCKING MIN. <br />4. SHEAR WALLS MORE THAN ONE VERTICAL PANEL IN HEIGHT SHALL HAVE EITHER VERTICAL OR HORIZONTAL STAGGERED SPLICED JOINTS. <br />5. PROVIDE 112" MIN. EDGE DISTANCE FOR ALL PLYWOOD EDGE NAILING. NAILS SHALL BE PLACED NOT LESS THAN 12"in FROM THE PANEL EDGES AND NOT LESS THAN 38" FROM THE EDGE <br />OF THE CONNECTION MEMBERS FOR SHEAR GREATER THAN 350 plf. NAILS SHALL BE PLACED NOT LESS THAN 38" FROM PANEL EDGES AND NOT LESS THAN 14" FROM THE EDGE OF THE <br />CONNECTING MEMBERS FOR SHEARS OF 350plf OR LESS. <br />6. ONLY COMMON NAILS ARE TO BE USED FOR ALL PLYWOOD SHEATHING ATTACHMENT. <br />7. NAIL GUNS USING "CLIPPED HEAD" OR "SINKER" NAILS ARE NOT ACCEPTABLE. <br />8. ALL BOLT HOLES TO BE DRILLED 1/32" MIN. TO 1/16" MAX. OVERSIZED. <br />9. USE DOUGLAS FIR # 2 PRESSURE TREATED SILL PLATES. ALL NAILS & ANCHOR BOLTS IN PRESSURE TREATED SILL PLATES SHALL BE HOT DIPPED ZINC-COATED GALVANIZED STEEL <br />PER ASTM A 153. ANCHOR BOLTS MAY HAVE A MECHANICALLY DEPOSITED ZINC COATING WITH WEIGHTS PER ASTM B 696, CLASS 55. <br />10. ANCHOR BOLTS MUST BE EMBEDDED 7" MIN. INTO NEW CONCRETE. WHERE SHEAR WALLS ARE TO BE ATTACHED TO EXISTING FOOTINGS, EPOXY 5/8"DIA THREADED ROD ANCHORS <br />WITH 5" MIN. EMBEDMENT USING SIMPSON 'SET-XP' HIGH STRENGTH ADHESIVE (ESR-2508) WITH SPECIAL INSPECTION (OR) 5 8" DIA x 6" LONG SIMPSON 'TITEN HD' ANCHORS <br />(ESR-2713) INSTALLED AT THE SPACING INDICATED IN THE SHEAR WALL SCHEDULE <br />11. FOUNDATION ANCHOR BOLTS IN ALL SHEAR WALLS SHALL HAVE A MINIMUM 3" x 3" x 1 4" THICK PLATE WASHERS BETWEEN THE SILL PLATE AND NUT. THE NUTS SHALL BE TIGHTENED <br />JUST PRIOR TO COVERING THE WALL FRAMING. <br />12. STUCCO AND/OR EXTERIOR VENEER OVER A PLYWOOD SHEARWALL SHALL BE WATERPROOFED W/ A MIN. OF (2) LAYERS OF # 15LB. FELT PAPER. <br />13. ALL FRAMING MEMBERS RECEIVING EDGE NAILING FROM ABUTTING PANELS SHALL BE 3-INCH NOMINAL OR THICKER. ALL EDGE NAILING SHALL BE STAGGERED. <br />14. WHERE PLYWOOD PANELS ARE APPLIED ON BOTH FACES OF A WALL, USE A 3x6 BOT./SILL PLATE, 3x6 STUDS @ 16"o.c., AND 3x6 df. # 2 DOUBLE TOP PLATES. ALL FRAMING MEMBERS <br />RECEIVING EDGE NAILING FROM ABUTTING PANELS SHALL BE 4-INCH NOMINAL OR THICKER. ALL EDGE NAILING SHALL BE STAGGERED AND BOTH VERTICAL AND HORIZONTAL <br />INTERIOR PANEL JOINTS ON OPPOSITE SIDES OF THE WALL SHALL BE STAGGERED. SEE WOOD NOTES # 18 FOR ADDITIONAL REQUIREMENTS. <br />15. WHEN 'LTP4' IS INSTALLED OVER PLYWOOD, USE USE 8d COMMON NAILS. <br />16. WHERE BOTTOM PLATE NAILING GOES THROUGH FLOOR SHEATHING THICKER THAN3 4", USE 20d NAILS AT SAME SPACING AS INDICATED OR SIMPSON SDS25412 SCREWS AT TWICE <br />THE SPACING AS INDICATED. <br />17. IN SEISMIC CATEGORY "D", ALL EXTERIOR WALLS TO BE CONTINUOUSLY SHEATHED WITH A MIN. 12" THICK PLY/WOOD STRUCTURAL PANEL. <br />18. WHERE NAILS ARE IDENTIFIED AT 4" O.C. OR LESS, SPECIAL INSPECTION (SEISMIC) IS REQUIRED FOR STRUCTURAL WOOD. <br />19. WHERE PANELS ARE APPLIED ON BOTH FACES OF A SHEARWALL AND NAIL SPACING IS LESS THAN 6 INCHES ON CENTER ON EITHER SIDE, PANEL JOISTS SHALL BE OFFSET TO FALL <br />ON DIFFERENT FRAMING MEMBERS. ALTERNATIVELY, THE WIDTH OF THE NAILED FACE OF FRAMING MEMBERS SHALL BE 3" OR GREATER AT ADJOINING PANEL EDGES AND NAILS AT <br />ALL PANEL EDGES SHALL BE STAGGERED. <br />SHEAR WALL <br />DESIGN CRITERIA <br />FASTENER SCHEDULE <br />S1 <br />SN <br />STRUCTURAL NOTES <br />EQ.WIND <br />532 <br />364 <br />686 <br />896 <br />1218 <br />2010 W Alco Ave Unit <br />#24/22/2025