My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1606 N Mabury St - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Mabury St
>
1606 N Mabury St
>
1606 N Mabury St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2025 12:44:27 PM
Creation date
6/15/2025 12:44:01 PM
Metadata
Fields
Template:
Plan
Permit Number
101122069
Full Address
1606 N Mabury St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
110 <br /> 1'- <br />0 <br />" <br />MIN <br />DEPTH OF <br />FRAMING <br />SILL BIB S.A.F. <br />12" WIDE. INSTALL <br />FLUSH WITH R.O. <br />SILL, EXTEND MIN <br />12" BEYOND EACH <br />JAMB OF THE R.O., <br />STAPLE ALONG <br />TOP EDGE ONLY <br />JAMB S.A.F. <br />12" WIDE. INSTALL <br />FLUSH WITH R.O. <br />JAMB, EXTEND 11 1/2" <br />ABOVE R.O. HEAD <br />AND 11" BELOW R.O. <br />SILL. STAPLE ALONG <br />JAMB EDGE ONLY <br />WINDOW SETTING SEALANT <br />APPLY 1/2" BEAD OF <br />SEALANT TO MOUNTING <br />SIDE OF WINDOW FLANGE <br />BEFORE SETTING WINDOW, <br />OOZE OUT FROM BEHIND <br />WINDOW SHOULD OCCUR <br />UPON SETTING WINDOW <br />SILL PAN S.A.F. <br />12" WIDE <br />O/WINDOW SILL <br />AND SILL BIB <br />S.A.F. <br /> ROLL ENTIRE <br />SURFACE WITH <br />J-ROLLER <br />1 3 4 5 6 10 <br />W.R.B. <br />SLIPPED UNDER SILL <br />BIB S.A.F., APPLY <br />REMAINING W.R.B. IN <br />WEATHERBOARD <br />FASHION OVER AND <br />UNDER W.R.B. SILL <br />9*8* <br />GSM HEAD <br />FLASHING CAP W/ <br />CLOSED ENDS <br />(SOLDER SEAMS) <br />S.A.F. * <br />12" WIDE OVER <br />FLASHING SCREED <br />SOLID BACKING ALL FOUR <br />SIDES OF OPENING SHALL <br />EXTEND 1" MINIMUM BEYOND <br />THE EXTENT OF ALL APPLIED <br />WINDOW FLASHINGS <br />BUTTERED SEALANT <br />IMMEDIATELY AFTER SECURING WINDOW IN <br />THE OPENING, APPLY ADDITIONAL SEALANT <br />TO THE FRONT SURFACE OF THE WINDOW <br />NAILING FLANGE. TOOL SEALANT AND OOZE <br />OUT (STEP 5) TO A FULL KNOCK DOWN BEAD <br />THAT COVERS THE COMPLETE FLANGE AND <br />1" MINIMUM OF THE SURROUNDING MATERIAL <br />7 <br />HEAD FLANGE S.A.F. <br />12" WIDE. INSTALL BOTTOM <br />EDGE TO LAP WINDOW HEAD <br />FLANGE, EXTEND 1" BEYOND <br />JAMB S.A.F.. ADHERE TO <br />WINDOW HEAD FLANGE <br />WINDO <br />W <br />STAPLED <br />ALONG JAMB <br />EDGE UNDER <br />WINDOW FIN <br />WIDTH <br /> <br />O <br />F <br />ROUG <br />H <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br />WINDO <br />W <br />ROUG <br />H <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br />11 <br />" <br />11 <br /> <br />1 <br />/ <br />2 <br />" <br />WIN <br />D <br />O <br />W <br /> <br />R <br />O <br />U <br />G <br />H <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br />WINDO <br />W <br /> <br />R <br />O <br />U <br />G <br />H <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br /> <br />P <br />L <br />U <br />S <br /> <br />2 <br />6 <br />" <br />WIDTH <br /> <br />O <br />F <br /> <br />D <br />R <br />I <br />P <br /> <br />F <br />L <br />A <br />S <br />H <br />I <br />N <br />G <br />PLUS <br /> <br />6 <br />" <br /> WIN <br />D <br />O <br />W <br />OPENI <br />N <br />G <br />18" MI <br />N <br />I <br />M <br />U <br />M <br />. <br />13" BE <br />Y <br />O <br />N <br />D <br /> <br />R <br />. <br />O <br />. <br />* STEPS 8 AND 9 ARE NOT REQUIRED IF THE WINDOW IS PROTECTED BY A MIN. 30" DEEP EAVE OR SOFFIT <br />THAT IS WITHIN 24" OF THE WINDOW HEAD. THE EAVE OR SOFFIT SHALL EXTEND 30" EACH SIDE OF WINDOW. <br />2 <br />CORNER FLASHING <br />SET IN SEALANT <br />PER MFGR. <br />TRIM EXCESS <br />MATERIAL FLUSH <br />WITH INSIDE FACE <br />OF WINDOW SILL <br />4"4" <br />WINDOW FLASHING <br />SHEATHING MAY OCCUR <br />HEADER PER STRUCTURAL <br />FRAMING PER STRUCTURAL <br />INTERIOR FINISH <br />FRAMING PER STRUCTURAL <br />INTERIOR FINISH <br />3-COAT STUCCO SYSTEM <br />O/ METAL LATH O/ W.R.B. <br />SHEATHING MAY OCCUR <br />LOW EXPANSION FOAM ALL FOUR <br />SIDES OF WINDOW <br />SOLID BACKING REQUIRED WHEN <br />SHEATHING NOT PROVIDED <br />SOLID BACKING REQUIRED WHEN <br />SHEATHING NOT PROVIDED <br />CORNER FLASHING (BELOW) <br />APPLIED FOAM TRIM MAY OCCUR <br />SEE EXTERIOR ELEVATIONS <br />LOW EXPANSION FOAM ALL FOUR <br />SIDES OF WINDOW <br />LOW EXPANSION FOAM ALL FOUR <br />SIDES OF WINDOW <br />3-COAT STUCCO SYSTEM <br />O/ METAL LATH O/ W.R.B. <br />FOR ADDITIONAL INFORMATION SEE DETAILS 1 <br />- <br />FACTORY FINISHED WINDOW <br />SET <br />FACTORY FINISHED WINDOW <br />SET <br />APPLIED FOAM TRIM MAY OCCUR <br />SEE EXTERIOR ELEVATIONS <br />APPLIED FOAM TRIM MAY OCCUR <br />SEE EXTERIOR ELEVATIONS <br />GALVANIZED SHEET METAL HEAD <br />FLASHING CAP W/ SOLDERED CLOSED <br />ENDS W/ BOND BREAKER <br />FACTORY FINISHED WINDOW <br />SET <br />CORNER FLASHING (BEYOND) <br />HEAD <br />JAMB <br />SILL <br />SOLID BACKING REQUIRED WHEN <br />SHEATHING NOT PROVIDED <br />FRAMING PER STRUCTURAL <br />INTERIOR FINISH <br />W.R.B. TO COVER S.A.F. <br />3-COAT STUCCO SYSTEM <br />O/ METAL LATH O/ W.R.B. <br />SHEATHING MAY OCCUR <br />1/ <br />2 <br />" <br />SL <br />2 : 12 <br />SL <br />2 : 12 <br />1/2" <br />1/ <br />2 <br />" <br />WINDOWDOOR FLASHING PAN INSTALLATION <br />GSM HEAD FLASHING CAP - INSTALL FLASHING SCREED AS REQUIRED BY DETAIL. EXTEND THE <br />SCREED 2" PAST THE ROUGH OPENING AT BOTH ENDS. SET SCREED ONTO HEAD PLASTER MOULD <br />WITH SEALANT. NOT REQUIRED IF THE DOOR IS PROTECTED BY A MINIMUM 30" DEEP EAVE OR <br />SOFFIT THAT IS WITHIN 24" OF THE DOOR HEAD, THE EAVE OR SOFFIT SHALL EXTEND 30" EACH <br />SIDE OF DOOR. <br />STEP <br />W.R.B. - APPLY W.R.B. IN WEATHERBOARD FASHION AROUND THE INSTALLED DOOR. <br />2 <br />STEP 6A <br />FLASHING CORROSION RESISTANT PAN - INSTALL ALONG BOTTOM OF OPENING, SET IN SEALANT <br />AND FASTEN THROUGH THE VERTICAL LEGS ONLY TO THE ROUGH FRAMING JAMBS. <br />WEEP S.A.F. - ADHERE 9" WIDE S.A.F. OVER CEMCO #3 FLASHING SCREED. EXTEND THE S.A.F. 2" <br />PAST THE CEMCO #3 FLASHING SCREED AT BOTH ENDS; S.A.F. REQUIRED WITH CEMCO #3. <br />1STEP <br />6B <br />STEP <br />STEP 7 <br />"L" METAL - INSTALL AT DECK TO WALL TRANSITION, PROVIDE SOLID BACKING AT VERTICAL LEGS <br />AND INSTALL WITH A MINIMUM 4" LAP BETWEEN PIECES. ALL JOINTS SOLDERED. <br />3STEP PLACE DOOR FRAME - PLACE THE DOOR FRAME IN THE ROUGH OPENING. PLUMB, SQUARE, AND <br />SHIM THE DOOR, THEN FASTEN THE DOOR FRAME TO THE JAMB STUDS. <br />STEP 4 JAMB S.A.F. - ATTACH A STRIP OF S.A.F. ALONG EACH SIDE OF JAMB, ADHERING TO THE ROUGH <br />FRAMING AND DOOR FRAME JAMB. ALIGN EDGE OF S.A.F. TO INSIDE OF DOOR FRAME JAMB . THE <br />S.A.F. SHALL OVERLAP THE "L" METAL AND PAN FLASHING AND EXTEND 12" ABOVE THE HEAD <br />ROUGH OPENING. PRIME SUBSTRATE AS REQUIRED BY S.A.F. MANUF. <br />STEP 5 HEAD S.A.F. - ADHERE S.A.F. ABOVE THE ROUGH OPENING. EXTEND THE S.A.F. 13" PAST THE ROUGH <br />OPENING AT EACH END. ALIGN THE BOTTOM EDGE OF THE S.A.F. WITH THE BOTTOM OF THE DOOR <br />FRAME HEAD. <br />STEP 5A PLASTER MOULD. - APPLY PLASTER MOULD TO DOOR FRAME ON CONTINUOUS SEALANT. PLASTER <br />MOULD SHALL ALIGN WITH INSIDE EDGE OF DOOR FRAME. PLASTER MOULD SHALL BE BACK PRIMED. <br />ROU <br />G <br />H <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br /> <br />W <br />I <br />D <br />T <br />H <br />GSM HEAD FLASHING CAP - SET <br />FLASHING SCREED IN SEALANT TO <br />PLASTER MOULD HEAD. <br />STEP JAMB S.A.F <br />STEP <br />4 <br />2" <br />6A <br />6BSTEP WEEP S.A.F. - ADHERE O/ CEMCO #3 <br />FLASHING SCREED. <br />2" <br />ROUG <br />H <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br /> <br />W <br />I <br />D <br />T <br />H <br /> <br />P <br />L <br />U <br />S <br /> <br />2 <br />6 <br />" <br />2" <br />STEP PLASTER MOULD - APPLY PLASTER <br />MOULD TO DOOR FRAME ON <br />CONTINUOUS SEALANT. <br />5A <br />SECTION AA <br />ROUG <br />H <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br /> <br />W <br />I <br />D <br />T <br />H <br /> <br />P <br />L <br />U <br />S <br /> <br /> <br /> <br /> <br /> <br /> <br />8 <br />" <br />STEP PLACE DOOR FRAME3 <br />STEP HEAD S.A.F.5 <br />4" <br />4 <br />2 <br />- <br />- <br />A <br />B <br />- <br />11 <br />- <br />7" <br />2" <br />4" <br />LAP <br />TYP <br />4" <br />4" <br />LAP <br />TYP <br />VE <br />R <br />I <br />F <br />Y <br />STEP <br />STEP <br />STEP 5 <br />- <br />B <br />A <br />12 <br />" <br />ROUGH OPENING WIDTH PLUS 26" <br />HEAD S.A.F. <br />ADHERED <br />JAMB S.A.F. <br />FLASHING PAN <br />ATTACH FLASHING PAN <br />AT VERTICAL SIDES ONLY <br />ROUGH OPENING WIDTH <br />F.F. <br />11 <br />- <br />13" <br />STEP 3 <br />PLACE DOOR <br />FRANE <br />COOR <br />D <br />I <br />N <br />A <br />T <br />E <br />WITH <br />T <br />H <br />R <br />E <br />S <br />H <br />O <br />L <br />D <br />4" LA <br />P <br />4" <br />PAN FLASHING* - SOLDER ALL JOINTS. <br />WHEN "L" FLASHING HAS LESS THAN A 2" <br />VERTICAL RISE BETWEEN THE DECK AND <br />PAN, CONSTRUCT PAN AND "L" FLASHING <br />AS INTEGRAL ONE PIECE. COORDINATE <br />PAN DEPTH AND LIP HEIGHT WITH EACH <br />SPECIFIC THRESHOLD, FABRICATE PAN <br />TO MAXIMIZE DEPTH YET ELIMINATE <br />THRESHOLD ANCHOR PENETRATIONS <br />THROUGH THE PAN. <br />4" <br />4" <br /> <br /> <br /> <br /> <br /> <br /> <br />1 <br />/ <br />8 <br />" <br /> <br /> <br />M <br />I <br />N <br />LIP <br />4"ROU <br />G <br />H <br /> <br />O <br />P <br />E <br />N <br />I <br />N <br />G <br />2" <br />SECTION BB <br />VE <br />R <br />I <br />F <br />Y <br />1 <br />STEP <br />"L" FLASHING* <br />2 <br />STEP <br />* USE STAINLESS STEEL "L" AND PAN FLASHING AT CONCRETE SLAB OR DECK. COAT <br /> GSM "L" AND PAN FLASHING WITH PROTECTIVE MEMBRANE AT WOOD DECKS PER DETAIL <br />DOOR <br />SHEATHING MAY OCCUR <br />2x SOLID BACKING REQUIRED AT S.A.F. <br />WHEN SHEATHING NOT PROVIDED <br />DOOR AND FRAME <br />HEAD <br />JAMB <br />APPLIED FOAM TRIM MAY OCCUR, <br />SEE EXTERIOR ELEVATIONS <br />FOR ADDITIONAL INFORMATION SEE DETAILS <br />3-COAT STUCCO SYSTEM <br />O/ METAL LATH O/ W.R.B. <br />PERIMETER GASKET <br />JAMB S.A.F. EXTEND DOWN <br />O/ PAN FLASHING & L FLASHING <br />10 <br />- <br />PLASTER MOULD O/ SEALANT <br />O/ S.A.F. O/ DOOR FRAME JAMB <br />VERIFY FRAME <br />WIDTH WITH <br />WALL REQ'MT. <br />FRAMING PER STRUCTURAL <br />DOOR SHIM <br />LOW EXPANSION FOAM <br />APPLY WITHIN SHIM CAVITY <br />INTERIOR FINISH <br />SHEATHING MAY OCCUR <br />HEADER PER STRUCTURAL <br />3-COAT STUCCO SYSTEM <br />O/ METAL LATH O/ W.R.B. <br />W.R.B. O/ 9" WIDE WEEP S.A.F. <br />O/ HEAD FLASHING CAP <br />O/ DOOR HEAD S.A.F. <br />2x SOLID BACKING REQUIRED <br />AT S.A.F. WHEN SHEATHING <br />NOT PROVIDED <br />DOOR AND FRAME <br />GSM HEAD FLASHING CAP, WHEN <br />REQUIRED BY DETAIL 3 THIS SHEET <br />SET IN SEALANT OVER PLASTER <br />MOULD <br />APPLIED FOAM TRIM MAY OCCUR; <br />SEE EXTERIOR ELEVATIONS <br />PERIMETER GASKET <br />INTERIOR FINISH <br />FRAMING PER STRUCTURAL <br />BOND BREAKER <br />PLASTER MOULD O/ SEALANT <br />O/ S.A.F. O/ DOOR HEAD W/ BEAD OF <br />SEALANT AT HEAD AND MOULD <br />1/ <br />2 <br />" <br />MI <br />N <br />. <br />SL <br />2 : 12 <br />2DOOR THRESHOLD <br />WATERPROOF MEMBRANE OVER <br />AND UNDER THRESHOLD PAN <br />FLASHING <br />HARDSCAPE BELOW SCREED <br />CORROSION RESISTANT THRESHOLD <br />FLASHING PAN <br />ISOLATE DISSIMILAR METALS & <br />METAL TO CONCRETE. <br />LANDING SLOPE <br />1/4" = 1'-0" MAX <br />10 <br />- <br />7 <br />3 4" <br />MA <br />X <br />THRESHOLD INSTALL PER MANUF. <br />DOOR BOTTOM <br />"PEMKO" 34SD OR EQ. <br />5 <br />7 <br />6 <br />2" <br /> <br />M <br />I <br />N <br />. <br />STUCCO WEEP SCREED <br />SLOPE <br />8" <br /> <br />M <br />I <br />N <br />. <br />SHEATHING MAY OCCUR PROVIDE A <br />CONTINUOUS FLUSH SUBSTRATE <br />FURR OUT WALL PLANE ADJACENT TO <br />SHEAR PANELS TO EQUAL THICKNESS <br />2X P.T.D.F. SILL PLATE (3X MAY <br />OCCUR SEE STRUCT. PLANS) <br />CONTINUOUS NON HARDENING VINYL <br />CAULK (3) BEADS OR 1" WIDE STRIP <br />HARDSCAPE MAY OCCUR <br />INTERIOR FINISH <br />FINISH GRADE <br />FRAMING PER STRUCTURAL <br />WEEP SCREED 26 GA. GALV. MTL. W/ <br />3 1/2" HIGH NAILING FLANGE <br />3-COAT STUCCO SYSTEM <br />O/ METAL LATH O/ W.R.B. <br />W.R.B. O/ 9" WIDE S.A.F. O/ WEEP SCREED <br />4" <br /> <br />M <br />I <br />N <br />. <br />DETAILS <br />No.Date Description <br />AD-01 <br />Client <br />Project No:23-1107 <br />PHONE NO. <br />NPS MANAGEMENT <br />4401 ATLANTIC AVE #200 <br />LONG BEACH, CA 90807 <br />562-528-8100 <br />JWAIM DESIGN <br />714-494-6810 <br />jwaimdesign@gmail.com <br />CCOPYRIGHT <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />GA <br />R <br />A <br />G <br />E <br /> <br />A <br />D <br />U <br />16 <br />0 <br />6 <br /> <br />N <br /> <br />M <br />A <br />B <br />U <br />R <br />Y <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />No.Date Description <br />1606 N Mabury St <br />4/28/2025
The URL can be used to link to this page
Your browser does not support the video tag.