Laserfiche WebLink
CONTINUOUS FOOTING DESIGN <br />Roof dead load, RDL =11 psf Floor dead load, FDL=16 psf <br />Roof live load, RLL =20 psf Floor live load, FLL=40 psf <br />Ceiling dead load, CDL=5 psf Wall dead load, WDL=15 psf <br />Ceiling live load, CLL=10 psf <br />Tributary roof width, TRW=24.0 /2 =12 ft Tributary floor width, TFW=0.0 /2 =0 ft <br />Tributary ceiling width, TCW=24.0 /2 =12 ft Wall height, H=8 ft <br />Allowable pressure, AP=1000 psf <br />Total Weight, Wt=(RDL+RLL)*TRW + (CDL+CLL)*TCW + (FDL+FLL)*TFW +WDL*H=672.0 plf <br />Use footing width, FTGw =12 in =1 ft <br />Use footing depth, FTGd =12 in =1 ft <br />Rebars:2 - #4 at top and bottom <br />Design pressure, DP =Wt / FTGw =672.0 psf <1000 psf; OK <br />Tributary roof width, TRW=24.0 /2 =12 ft Tributary floor width, TFW=0.0 /2 =0 ft <br />Tributary ceiling width, TCW=24.0 /2 =12 ft Wall height, H=8 ft <br />Allowable pressure, AP=1000 psf <br />Total Weight, Wt=(RDL+RLL)*TRW + (CDL+CLL)*TCW + (FDL+FLL)*TFW +WDL*H=672.0 plf <br />Use footing width, FTGw =12 in =1 ft <br />Use footing depth, FTGd =12 in =1 ft <br />Rebars:2 - #4 at top and bottom <br />Design pressure, DP =Wt / FTGw =672.0 psf <1000 psf; OK <br />1621 S Diamond St & <br />Unit# 24/24/2025