My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
710 S Gates St - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Gates St
>
710 S Gates St
>
710 S Gates St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2025 12:44:28 PM
Creation date
6/15/2025 12:44:01 PM
Metadata
Fields
Template:
Plan
Permit Number
101121791
Full Address
710 S Gates St
Stamp
ID:
1
Creator:
Import Agent
Created:
6/15/2025 12:44 PM
Modified:
6/10/2025 11:41 AM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FAU <br />(E) ATTIC ACCESS <br />w/ (N) SWITCH & LIGHT <br />FAMILY ROOM <br />C.H. 8'-1" <br />W <br />D <br />BEDROOM #4 <br />C.H. 8'-1" <br />GARAGE <br />LIVING ROOM <br />VAULTED CEILING <br />DINING ROOM <br />VAULTED CEILING <br />KITCHEN <br />VAULTED CEILING <br />HALL <br />BATH #2 <br />M. BATH <br />BEDROOM #2 <br />VAULTED CEILING <br />BEDROOM #3 <br />VAULTED CEILING <br />CL <br />O <br />S <br />E <br />T <br />CL <br />O <br />S <br />E <br />T <br />CL <br />O <br />S <br />E <br />T <br />CL <br />O <br />S <br />E <br />T <br />M. BEDROOM <br />VAULTED CEILING <br />1' <br />- <br />4 <br />" <br />30 <br />' <br />- <br />1 <br />0 <br />" <br />5' <br />- <br />0 <br />" <br />8' <br />- <br />1 <br />0 <br />" <br />20 <br />' <br />- <br />1 <br />" <br />67 <br />' <br />- <br />9 <br />" <br />9'-0"5'-0"13'-0"4'-0"16'-4"1'-4"1'-4" <br />50'-0" <br />20 <br />' <br />- <br />3 <br />" <br />15 <br />' <br />- <br />3 <br />" <br />9' <br />- <br />6 <br />" <br />18 <br />' <br />- <br />5 <br />" <br />11 <br />' <br />- <br />5 <br />" <br />37 <br />' <br />- <br />1 <br />1 <br />" <br />67 <br />' <br />- <br />9 <br />" <br />13'-1"13'-3"23'-0" <br />50'-0" <br />7'-2"8'-2"3'-9" <br />2 <br />3 <br />4 <br />4 <br />5 <br />6 <br />7 <br />A <br />B <br />CD <br />(E) 16'-0"x7'-0" ROLL-UP <br />GARAGE DOOR <br />REAR PATIO #1 <br />REAR PATIO #2 <br />(N <br />) <br />3 <br />0 <br />6 <br />8 <br />9'-8" <br />E <br />F <br />F <br />F F F F F F <br />F <br />F <br />F <br />F <br />LED <br />LED <br />LED <br />LED <br />LED <br />LED <br />LED <br />LED <br />LED LED <br />LED LED <br />LED LED <br />LED <br />LED <br />LED <br />LED <br />S <br />S <br />S <br />S S <br />S S <br />S 3 <br />S 3 <br />S <br />3 <br />S <br />3 <br />S D <br />S D <br />S D <br />S <br />D <br />S D <br />S <br />OC <br />S <br />OC <br />S <br />OC <br />AC <br />REPLACE AC CONDENSER <br />GFI <br />GFI <br />GF <br />I <br />GFI <br />GF <br />I <br />GF <br />I <br />GF <br />I <br />GF <br />I <br />GFI <br />GFI <br />GFI <br />GFI <br />GFI <br />GFI <br />GFI <br />GFI <br />GFI <br />GFI <br />AFI <br />AFI <br />AF <br />I <br />AF <br />I <br />AFI <br />AF <br />I <br />AF <br />I <br />AF <br />I <br />AF <br />I <br />AF <br />I <br />AFIAFI <br />AFIAFI <br />AFI <br />AFIAFI <br />AFI <br />AF <br />I <br />AF <br />I <br />AF <br />I <br />AF <br />I <br />AFI <br />AFI <br />AFI <br />AFI <br />AFI <br />AF <br />I <br />AF <br />I <br />WP <br />WP <br />WP <br />SDCO <br />SD <br />SD <br />SD <br />SD <br />S D <br />S <br />LED LED <br />LED LED <br />SLEDLED <br />LED LED <br />S D <br />S <br />LEDLED <br />LEDLED <br />LED <br />LED <br />LED <br />LED <br />LED <br />S D <br />S <br />A-3 <br />A <br />A-3 <br />B <br />PROVIDE TIGHT FITTING <br />SELF-CLOSING 1 3/8" THICK, <br />SOLID WOOD DOOR (OR 20 <br />MIN. RATED DOOR) BETWEEN <br />GARAGE AND HOUSE TYP. <br />PROVIDE 5/8" TYPE-X GYPSUM BOARD <br />AT ALL GARAGE WALLS WHICH ARE <br />ADJACENT TO DWELLING <br />1 <br />S <br />3'-0" <br />5' <br />- <br />1 <br />0 <br />" <br />(N) CLOSET <br />W/H <br />GFI <br />10'-1"12'-4" <br />2' <br />- <br />2 <br />" <br />6'-9" <br />SDCO <br />EXISTING STUD WALL <br />NEW <br />EXISTING <br />WALL LEGEND: <br />(E) <br />(N) <br />REMOVE(R) <br />NEW WALL <br />REMOVE WALL <br />PONY WALLP. W. <br />MISC. NOTES: <br />1.ALL NEW WINDOWS AND SLIDING GLASS DOORS SHALL BE <br />DUAL PANE, LOW-E ASSEMBLIES: <br />U-FACTOR = 0.30 <br />SGHC = 0.23 <br />2.ALL NEW BEDROOM WINDOWS SHALL PROVIDE MIN. EGRESS <br />SIZE AND HEIGHT REQUIREMENTS: <br />·5.7 SQ. FT. NET CLEAR OPENING <br />·24" NET CLEAR HEIGHT <br />·20" NET CLEAR WIDTH <br />·44" MAX. HEIGHT TO BOTTOM OF <br />CLEAR OPENING MEASURED FROM THE <br />FLOOR <br />8'-0" <br />No. <br />1 <br />WIDTH <br />5'-0" <br />HEIGHT OPENING <br />OXO <br />PANE <br />WINDOW SCHEDULE <br />5'-0"2 5'-0"SLW <br />3'-0"3 3'-0"BAY <br />2'-6"4 3'-0"SLW <br />6'-0"6 6'-8"SLDR <br />3'-6"7 SLW <br />8 SLW <br />MATERIAL <br />ALUMINUM <br />3'-0"5 5'-0"SH <br />9 SH <br />8'-0"10 6'-8"SLDR <br />TEMP GLASS U-FACTOR SGHC <br />NO ---- <br />A SLW <br />B SH <br />C SLDR <br />6'-0"D 6'-8"SLDR <br />NUMBERS= Existing windows, LETTERS= New Windows <br />SLDR <br />SLW <br />SLIDING DOOR <br />SLIDING WINDOW <br />DOUBLE <br />REMARKS <br />SH SINGLE HUNG <br />ALUMINUM NO ----DOUBLE <br />ALUMINUM NO ----DOUBLE <br />ALUMINUM YES ----DOUBLE <br />ALUMINUM NO ----DOUBLE <br />ALUMINUM YES ----DOUBLE <br />ALUMINUM NO ----DOUBLE <br />ALUMINUM NO ----DOUBLE <br />ALUMINUM NO ----DOUBLE <br />ALUMINUM YES ----DOUBLE <br />ALUMINUM NO 0.30 0.23DOUBLE <br />ALUMINUM NODOUBLE <br />ALUMINUM YESDOUBLE <br />ALUMINUM YESDOUBLE <br />2'-0" <br />3'-6"5'-0" <br />3'-0"5'-0" <br />3'-6"5'-0" <br />3'-0"5'-0"0.30 0.23 <br />0.30 0.23 <br />0.30 0.23 <br />E ALUMINUM NODOUBLE 0.30 0.23 <br />8'-0"6'-8" <br />SLW3'-0"5'-0" <br />W/ VERTICAL & HORIZONTAL GRIDS <br />W/ VERTICAL & HORIZONTAL GRIDS <br />W/ VERTICAL & HORIZONTAL GRIDS <br />W/ VERTICAL & HORIZONTAL GRIDS <br />W/ VERTICAL & HORIZONTAL GRIDS <br />W/ VERTICAL & HORIZONTAL GRIDS <br />W/ VERTICAL & HORIZONTAL GRIDS <br />W/ VERTICAL & HORIZONTAL GRIDS <br />W/ VERTICAL & HORIZONTAL GRIDS <br />W/ VERTICAL & HORIZONTAL GRIDS <br />W/ VERTICAL & HORIZONTAL GRIDS <br />SYMBOLS LEGEND <br />LIGHTING/EXHAUST FANS <br />HIGH EFFICACY WALL MOUNT MULTI-LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />(TWO TUBE) <br />FIXTURE <br />HIGH EFFICACY RECESSED LED FIXTURE <br />4" Ø DRYER VENT TO OUTSIDE <br />SWITCH <br />SWITCHES <br />3-WAY SWITCH <br />DIMMER SWITCH <br />OCCUPANCY SENSOR W/ MANUAL ON <br />DUPLEX OUTLET <br />ARC FAULT INTERRUPTED <br />DUPLEX OUTLET <br />WEATHERPROOF GROUND FAULT INTERRUPTED <br />DUPLEX OUTLET, TAMPER RESISTANT <br />SMOKE ALARM HARD WIRED INTO ELECTRICAL SYSTEM <br />(WITH BATTERY BACK-UP). DETECTORS SHALL BE <br />INTERCONNECTED SO THAT THE ACTIVATION OF ONE <br />ALARM WILL ACTIVATE ALL ALARMS. INSTALL PER NFPA <br />72, 2022 CRC & MFG. INSTALLATION INSTRUCTIONS. <br />CARBON MONOXIDE ALARM HARD WIRED INTO <br />ELECTRICAL SYSTEM (WITH BATTERY BACK-UP). <br />DETECTORS SHALL BE INTERCONNECTED SO THAT THE <br />ACTIVATION OF ONE ALARM WILL ACTIVATE ALL <br />ALARMS. SHALL COMPLY WITH UL 2034, UL 2075 AND/OR <br />NFPA 720. <br />EXISTING ELECTRICAL MAIN (100 AMP.) <br />OUTLETS <br />GENERAL UTILITY <br />F <br />F <br />LED <br />S <br />S 3 <br />S D <br />S OC <br />GFI <br />AFI <br />WP <br />SD <br />CO <br />GROUND FAULT INTERRUPTED <br />F EXHAUST FAN - 50 CFM MIN - VENTED TO <br />OUTSIDE AIR -MAX 1 SONES - WITH <br />HUMIDISTAT - AND HIGH EFFICACY LIGHT <br />EXHAUST FAN - 100 CFM MIN - <br />VENTED TO OUTSIDE AIR <br />MOTION SENSING WALL HUNG LIGHT FIXTURE <br />CONTROLLED BY WHOLE HOUSE PHOTOCELL <br />240 V CIRCUIT BREAKER FOR A.C. <br />COMPRESSORAC <br />FAN MOTOR ON SEPARATE SWITCHES) <br />CEILING FAN WITH CFL'S (CFL AND <br />A-2 <br />PROPOSED FLOOR PLAN <br />SCALE: 1/4" = 1'-0" <br />GENERAL NOTES <br />ANY UNAUTHORIZED REUSE OF THESE PLANS OTHER <br />THAN THE PROJECT AND LOCATION SHOWN IS <br />PROHIBITED. <br />ALL IDEAS, DESIGNS AND PLANS REPRESENTED BY <br />THE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF <br />BCI ENGINEERING AND SHALL NOT BE REPRODUCED <br />IN WHOLE OR IN PART WITHOUT THE EXPRESS PRIOR <br />WRITTEN PERMISSION OF SAID ENGINEER. <br />15375 BARRANCA PKWY. SUITE B-205 <br />IRVINE, CA 92618 <br />(714) 267-6561 <br />ben.ionescu@bciengineeringcompany.com <br />SCALE <br />AS NOTED <br />SHEET <br />No.REVISION/ ISSUE DATE <br />FIRE RESTORATION PROJECT <br />PROJECT NAME AND ADDRESS: <br />RICHARD PONCE <br />710 S GATES ST <br />SANTA ANA, CA 92704 <br />PROJECT <br />PONCE <br />DATE <br />OCT, 2024 <br />1 PER CITY REQUEST 1/15/25 <br />REPLACE <br />FAU <br />EXISTING 100 AMP <br />ELECTRICAL MAIN PANEL <br />1 <br />1 <br />REPLACE EXISTING 50 <br />GAL WATER HEATER <br />- <br />1 <br />1 NO SCALE <br />WATER HEATER STRAP <br />1 <br />1 <br />710 S Gates St <br />2/12/2025
The URL can be used to link to this page
Your browser does not support the video tag.