Laserfiche WebLink
(N) ROOF RAFTERS <br />2x8 LEDGER <br />PATIO RAFTER <br />LUS28 <br />12"x5-1/2" LAG BOLTS INTO <br />BEAM @ 16" O.C. STAGGERED <br />(16' MAX. RAFTER SPAN, > 16' <br />USE 2 LAG BOLTS @ 16" O.C. <br />PRE-DRILL ALL HOLES 38"Ø) <br />(Note: Lag bolts must <br />go into 4X beam and holes <br />for lag screws must be pre-drilled) <br />EXISTING STUD <br />WALL <br />(N) LUS28 <br />HANGER <br />(E) 4x14 BEAM <br />E.N. <br />2%2% <br />E.N. <br />PLY SHTG. <br />2x BLK <br />A35 @ 16" O.C. <br />RAFTER <br />(PER PLAN) <br />H2.5 @ 32" O.C. <br />2x RIM <br />CANT. <br />SLOPE <br />1/4":1' MIN <br />BEAM PER PLAN <br />POST PER PLAN <br />SIMPSON "PC" OR <br />"EPC" <br /> Hot Mop class A roof <br />(CERTAINTEED ESR-1388) over 2 <br />layers 15lb felt over 1/2" plywood CDX <br />or with 8d nails @ 6"-6"-12" O.C. <br />5/8" MB-BOLTS <br />W/WASHERS <br />(TYP. @ALL <br />CONNECTIONS), <br />UNO <br /> Hot Mop class A roof <br />(CERTAINTEED ESR-1388) over 2 <br />layers 15lb felt over 1/2" plywood CDX <br />or with 8d nails @ 6"-6"-12" O.C. <br />(N) POST SEE PLAN <br />A 35 BOTH SIDES <br />A 35 3x6 PTDF <br />(E) FOOTING <br />4" CONCRETE <br />SLAB-ON-GRADE <br />2X P.T. SILL PLATE <br />W/WS1254 <br />@24" o.c. BY <br />REDHEAD R.R. <br />#2748 <br />2X @ 16" o.c. <br />WOOD STUDS <br />PLYWOOD <br />STAGGER END JOINTS OF <br />FACE GRAIN <br />TYP PLYWOOD SHEET <br />BOUNDRY NAILING <br />EDGE NAILING <br />DIRECTION <br />FOR SIZE & SPACING <br />TYP JOISTS SEE PLAN <br />LAID PERPENDICULAR TO JOISTS <br />PLYWOOD FACE GRAIN TO BE <br />ROOF DIAPHRAGM <br />12" CDX <br />MIN. SPAN RATING 32/16 <br />UNBLOCKED <br />8d NAILS @ 6"-6"-12" O.C. <br />D-1 <br />1 NO SCALE <br />STUCCO SPLICE DETAIL (HORIZONTAL) <br />2 NO SCALE <br />STUCCO SPLICE DETAIL (VERTICAL) <br />3 NO SCALE <br />RAFTER TO WALL <br />4 NO SCALE <br />EAVE DETAIL @ REAR PATIO #1 <br />5 NO SCALE <br />KNEE BRACE DETAIL @ REAR PATIO #1 <br />6 NO SCALE <br />KNEE BRACE DEATIL @ REAR PATIO #1 <br />7 NO SCALE <br />NEW POST TO EXISTING CONC. PAD @ REAR PATIO #1 <br />8 NO SCALE <br />TOP PLATE SPLICE DETAIL <br />9 NO SCALE <br />NEW INTERIOR NON-BEARING WALL TO EXISTING SLAB ON GRADE <br />10 NO SCALE <br />PLYWOOD DIAPHRAGM <br />11 NO SCALE <br />DETAIL <br />12 NO SCALE <br />DETAIL <br />GENERAL NOTES <br />ANY UNAUTHORIZED REUSE OF THESE PLANS OTHER <br />THAN THE PROJECT AND LOCATION SHOWN IS <br />PROHIBITED. <br />ALL IDEAS, DESIGNS AND PLANS REPRESENTED BY <br />THE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF <br />BCI ENGINEERING AND SHALL NOT BE REPRODUCED <br />IN WHOLE OR IN PART WITHOUT THE EXPRESS PRIOR <br />WRITTEN PERMISSION OF SAID ENGINEER. <br />15375 BARRANCA PKWY. SUITE B-205 <br />IRVINE, CA 92618 <br />(714) 267-6561 <br />ben.ionescu@bciengineeringcompany.com <br />SCALE <br />AS NOTED <br />SHEET <br />No.REVISION/ ISSUE DATE <br />FIRE RESTORATION PROJECT <br />PROJECT NAME AND ADDRESS: <br />RICHARD PONCE <br />710 S GATES ST <br />SANTA ANA, CA 92704 <br />PROJECT <br />PONCE <br />DATE <br />OCT, 2024 <br />710 S Gates St <br />2/12/2025