My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1902 W Monica Ln - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Monica Ln
>
1902 W Monica Ln
>
1902 W Monica Ln - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2025 12:44:28 PM
Creation date
6/15/2025 12:44:02 PM
Metadata
Fields
Template:
Plan
Permit Number
20184530
Full Address
1902 W Monica Ln
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
NOTES SHEET <br />002 NS1 <br />JURISDICTION NOTES ELECTRICAL NOTES <br />CONSTRUCTION NOTES <br />UTILITY NOTES <br />1.ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION <br />INSTRUCTIONS. <br />2.ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. <br />3.ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. <br />4.THE SOLAR INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING OR MECHANICAL VENTS. <br />5.A LADDER WILL BE IN PLACE FOR INSPECTIONS IN COMPLIANCE WITH OSHA REGULATIONS. <br />6.MODULE MOUNTING STRUCTURE WILL BE TIED DIRECTLY INTO STRUCTURAL ELEMENTS OF SINGLE FAMILY <br />DWELLING ROOF TRUSSES / RAFTERS OR BEAMS ACCORDING TO MOUNTING STRUCTURE DIRECTIONS. <br />7.ROOF COVERING PENETRATIONS SHALL BE DESIGNED, INSTALLED AND MAINTAINED IN ACCORDANCE WITH <br />BUILDING CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERINGS <br />SHALL SERVE TO PROTECT THE BUILDING STRUCTURE. <br />8.CONDUIT, WIRING SYSTEMS, AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE <br />AS POSSIBLE TO THE RIDGE, HIP, OR VALLEY. THIS EQUIPMENT SHALL ALSO BE LOCATED AS CLOSE AS <br />POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES. <br />9.MODULES MUST HAVE 6" CLEARANCE FROM ALL VENTS AND OBSTRUCTIONS. <br />CODE REFERENCES <br />GENERAL NOTES <br />1.RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEM <br />SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />MANUFACTURES SPECIFICATIONS AND THE 2022 <br />CALIFORNIA RESIDENTIAL CODE, SECTIONS R314, R909 <br />AND R918, 2022 CALIFORNIA ELECTRICAL CODE AND <br />2022 CALIFORNIA FIRE CODE. <br />2.CONTRACTORS SHALL BE PRESENT DURING ALL <br />INSPECTIONS. <br />3.THE ROOF ACCESS POINT REQUIRING A LADDER SHALL <br />NOT BE LOCATED OVER A WINDOW, DOOR OR LOCATED <br />WHERE IT CONFLICTS WITH OVERHEAD OBSTRUCTIONS <br />SUCH AS TREE LIMBS, WIRES OR SIGNS [CRC 324.7.1]. <br />4.A LADDER SHALL BE PROVIDED AND SECURED TO THE <br />STRUCTURE AT THE APPROVED ROOF ACCESS POINT <br />PER NOT "C" ABOVE WITH A CAL OSHA APPROVED <br />DEVICE DURING ALL INSPECTIONS. <br />5.EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST <br />OUTLETS, VENTILATION'S INTAKE AIR OPENINGS SHALL <br />NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC <br />SYSTEM. <br />6.ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A <br />RECOGNIZED ELECTRICAL TESTING LABORATORY AND <br />INSTALLED PER THE LISTING REQUIREMENTS AND THE <br />MANUFACTURER'S INSTRUCTIONS. [NEC 690.4(D)] <br />7.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, <br />INCLUDING ALL ROOF MOUNTED TRANSITION BOXES <br />AND SWITCHES. <br />8.CONTACT THE SERVICING UTILITY BEFORE POWERING <br />ON THE PHOTOVOLTAIC SYSTEM <br />9.ALL WORK SHALL COMPLY WITH APPLICABLE, LOCAL, <br />MUNICIPAL CODES, AND TO MANUFACTURERS' LISTINGS <br />AND INSTALLATION INSTRUCTIONS. THE PV SOLAR <br />SYSTEM WILL BE INTERCONNECTED AND OPERATED IN <br />PARALLEL WITH THE UTILITY ELECTRICAL GRID PER THE <br />REQUIREMENTS OF THE UTILITY AND APPLICABLE <br />CODES. THE PV SOLAR SYSTEM IS DESIGNED IN <br />COMPLIANCE WITH CEC 690.12 (RAPID SHUTDOWN). <br />BETTER EARTH ELECTRIC INC. <br />16720 MARQUARDT AVE CERRITOS <br />CERRITOS, CA 90703 <br />PHONE #: (888) 373-9379 <br />LIC #: C10-1024460 <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA RESIDENTIAL CODE <br />2022 CALIFORNIA FIRE CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />2022 CALIFORNIA GREEN CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2022 CALIFORNIA ENERGY CODE <br />1.PV SOURCE CIRCUIT(S) ARE TO BE <br />SUNLIGHT-RESISTANT PV-WIRE AS PERMITTED BY <br />CEC 690.31(B). <br />2.ALL DIRECT CURRENT CIRCUITS ARE TO BE <br />INSTALLED IN METAL RACEWAY FROM THE POINT OF <br />PENETRATION OF THE SURFACE OF THE BUILDING OR <br />STRUCTURE TO THE MAIN SERVICE PANEL AS <br />MANDATED BY CEC 690.31(E). <br />3.WEATHERPROOF J-BOX – NEMA 3R. <br />4.ROOFTOP CONDUIT SHALL BE A MINIMUM OF 7/8" <br />ABOVE THE ROOF SURFACE. <br />5.ALL WORK SHALL COMPLY WITH THE 2022 <br />CALIFORNIA ELECTRICAL CODE (C.E.C.) AND ALL <br />OTHER LOCAL CODES AS APPROVED BY THE <br />AUTHORITY HAVING JURISDICTION. <br />INSTALLER NOTES <br />JURISDICTION STAMPS <br />DESIGNER: TAYLOR BICKFORD <br />NEW PV SYSTEM: 9600W DC / 6960W AC <br />Jose Luis Melgoza <br />1902 Monica Ln, Santa Ana, CA 92706 <br />APN: 10104209 <br />DATE: 10/4/2024 TIME: 09:43 AM <br />DRAWING TITLE: <br />DRAWING PAGE: <br />SCALE:DESIGNER SIGNATURE: <br />This item has been digitally <br />signed and sealed on <br />03/31/26 <br />Oct 10, 2024 <br />1902 W Monica Ln <br />12/2/2024
The URL can be used to link to this page
Your browser does not support the video tag.