Laserfiche WebLink
Micro-grid interconnect device (MID) <br />Integrated PV and grid metering <br />Auto load-shedding <br />Compatible with micro and string solar inverter <br />Optional Smart-Circuits Module <br />Optional Generator Module <br />Coupling <br />Nominal AC Voltage <br />Phase <br />aPower Over Current Protection Device <br />Solar Input Over Current Protection Device <br />Backup Load Port Over Current Protection <br />Device <br />Generator Over Current Protection Device1 <br />Maximum Supply Fault Current <br />Busbar Rating <br />Smart Circuits Over Current <br />Protection Device2 <br />Work Modes <br />Communications <br />User Interface <br />Warranty <br />AC-coupled <br />120 / 208 V, 120 / 240 V, 60 Hz <br />2 W+N+PE <br />100 A Max <br />80 A Max <br />Self-Consumption, Time of Use, Emergency Backup <br />Ethernet / 4G / Wifi <br />FranklinWH App <br />12 years <br />20 kA <br />280 A <br />Opt. a 1 × 80 A Max @ 208 V / 240 V & 1 × 50 A Max @ 208 V / 240 V <br />Opt. b 1 × 80 A Max @ 208 V / 240 V & 2 × 50 A Max @ 120 V <br />Certifications <br />Seismic <br />Environmental <br />Emissions <br />UL 17413, UL 1741 PCS3, UL 673, UL 869A3, UL 9163, <br />CAN/CSA C22.2 No. 107.1-16, CSA C22.2 No. 29, CSA C22.2 No. 0.19 <br />AC 156, OSHPD, IEEE 693-2005 (high) <br />California Proposition 65 <br />RoHS Directive 2011 / EU <br />FCC Part 15 Class B, ICES 003 <br />Dimensions (H × W × D) <br />Weight <br />Mounting <br />31.5 in × 21.7 in × 6.3 in <br />(800 mm × 550 mm × 160 mm) <br />50 lb (23 kg) <br />Wall mount or floor mount <br />Enclosure Type <br />Operating Temperature <br />Operating Humidity (RH) <br />Altitude <br />Environment <br />NEMA 3R <br />-4°F to 122°F (-20°C to 50°C) <br />Up to 100% RH, condensing <br />Maximum 9,843 ft (3,000 m) <br />Indoor and outdoor rated <br />1. Generator Module is optional. <br />2. Smart Circuit Module is optional. <br />3. Sections from these standards were used during the safety evaluation and included in the UL 1741 listing. <br />200 A Max <br />200 A Max <br />31.5 in <br />(800 mm) <br />31.5 in <br />(800 mm) <br />21.7 in <br />(550 mm) <br />21.7 in <br />(550 mm) <br />6.3 in <br />(160 mm) <br />6.3 in <br />(160 mm) <br />Serves as the controller for all home power sources by interconnecting solar, <br />grid, batteries, and a standby generator to supply electricity to the home. <br />Seamlessly transitions the home supply from grid power to backup power so <br />that always-on appliances, such as the refrigerator and network router, will <br />not be affected when grid goes down. <br />PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS <br />COMPLIANCE INFORMATION ENVIRONMENTAL SPECIFICATIONS <br />W W W . F R A N K L I N W H . C O M <br />aGate <br />Intelligent energy management system <br />W W W . F R A N K L I N W H . C O M <br />Store solar generated power while the sun is shining. Use the stored <br />energy when needed to lower electric bills. Run heavy loads such as air <br />conditioners and water heaters as usual even during grid outages. <br />Provide homeowner peace of mind by fully charging before severe <br />weather events. <br />aPower <br />AC-coupled battery <br />Safe LFP chemistry <br />Built-in inverter <br />13.6 kWh per unit, up to 204 kWh (15 units) per aGate <br />5 kW continuous / 10 kW peak for 10s (discharge) <br />Normal operations down to -4°F (-20°C) <br />IP67 protection <br />Single aPower capable of starting a 4-Ton AC <br />First-of-its-kind 208 V compliant battery for multi-family housing <br />Battery Chemistry <br />Usable System Energy <br />Aggregate Throughput <br />Real Power (charge) <br />Real Power (discharge) <br />Load Start Capability <br />Nominal AC Voltage <br />Coupling <br />Phase <br />Round Trip Efficiency <br />Noise Emission <br />User Interface <br />Warranty <br />Work Modes <br />Lithium Iron Phosphate (LFP) <br />13.6 kWh per unit, up to 15 units1 per aGate <br />43 MWh <br />5 kW continuous, 7.6 kW peak for 30 minutes <br />5 kW continuous, 10 kW peak for 10 seconds <br />118 A LRA2 <br />120 / 208 V, 120 / 240 V, 60 Hz <br />AC-coupled <br />2 W+N+PE <br />89%3 <br />Self-Consumption, Time of Use, Emergency <br />Backup <br />ġ30 dB (A)4 <br />FranklinWH App <br />12 years <br />Certifications <br />Seismic <br />UL 9540, UL 9540A, UL 1741, UL 1973, IEEE 1547, <br />IEEE 1547.1, UN 38.3,CAN/CSA C22.2 No. 107.1-16 <br />AC 156, OSHPD, IEEE 693-2005 (high) <br />California Proposition 65 <br />RoHS Directive 2011 / EU <br />FCC Part 15 Class B, ICES 003 <br />Dimensions (H × W × D) <br />Weight <br />Mounting <br />Cooling <br />45.3 in × 29.5 in × 11.4 in <br />(1150 mm × 750 mm × 290 mm) <br />395 lb (179 kg) <br />Wall mount or floor mount <br />Natural air-cooled design <br />PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS <br />COMPLIANCE INFORMATION <br />Ingress Protection <br />Operating Temperature <br />Operating Humidity (RH) <br />Altitude <br />Environment <br />IP67 (Battery and power converter system), <br />IP56 (Wiring compartment) <br />-4°F to 122°F (-20°C to 50°C) <br />Up to 100% RH, condensing <br />Maximum 9,843 ft (3,000 m) <br />Indoor and outdoor rated <br />ENVIRONMENTAL SPECIFICATIONS <br />1. For 120 / 208V applications, max. 4 aPowers per aGate can be connected in parallel. Please contact us <br />if you have large capacity requirements. <br />2. Load start capability may vary. <br />3. At beginning of life, AC to battery to AC, 50% power rating. <br />4. 5 kW discharge power, no fan running. <br />45.3 in <br />(1150 mm) <br />45.3 in <br />(1150 mm) <br />29.5 in <br />(750 mm) <br />29.5 in <br />(750 mm) <br />11.4 in <br />(290 mm) <br />11.4 in <br />(290 mm) <br />ored <br />h as air <br />. <br />ere <br />Environmental <br />Emissions <br />1902 W Monica Ln <br />12/2/2024