Laserfiche WebLink
Ra <br />n <br />g <br />e <br />3 <br />3 <br />3 <br />3 <br />3 3 <br />3 <br />33 3 <br />3 <br />Dr <br />y <br />e <br />r <br />3 <br />3 <br />3 <br />GFCI GFCI <br />GFCI <br />GF <br />C <br />I <br />GFCI <br />GF <br />C <br />I <br />AFCI <br />AF <br />C <br />I <br />AFCIAFCI <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AFCI <br />AF <br />C <br />I <br />AFCIAFCI <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AFCI AFCI <br />AFCI <br />AF <br />C <br />I <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GFCI <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AF <br />C <br />I <br />GFCIGFCI <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GFCI <br />(E) LIVING AREA <br />(E <br />) <br /> <br />D <br />I <br />N <br />I <br />N <br />G <br /> <br />A <br />R <br />E <br />A <br />(E) BEDROOMBEDROOM <br />PO <br />R <br />C <br />H <br />OFFICE <br />SD CO <br />SD <br />SD <br />20' - 1" <br />46 <br />' <br /> <br />- <br /> <br />2 <br />" <br />19' - 0" <br />8' <br /> <br />- <br /> <br />0 <br />" <br />BEDROOM <br />SD CO <br />SD <br />SD <br />14 <br />' <br /> <br />- <br /> <br />4 <br />" <br />8' <br /> <br />- <br /> <br />6 <br />" <br />11 <br />' <br /> <br />- <br /> <br />4 <br />" <br />34 <br />' <br /> <br />- <br /> <br />2 <br />" <br />19' - 6" <br />CLOSET <br />CL <br />O <br />S <br />E <br />T <br />10' - 11"5' - 4"18' - 1" <br />(E <br />) <br /> <br />B <br />A <br />T <br />H <br />R <br />O <br />O <br />M <br />3' <br /> <br />- <br /> <br />6 <br />" <br />3' - 6" <br />CL <br />O <br />S <br />E <br />T <br />(N) 300.00 SQ.FT. <br /> PATIO <br />(E) GARAGE <br />25 <br />' <br /> <br />- <br /> <br />8 <br />" <br />20 <br />' <br /> <br />- <br /> <br />6 <br />" <br />53' - 3" <br />RELOCATED <br /> A/C <br />A <br />B <br />A <br />1 <br />2 <br />2 <br />2 <br />4 <br />3 <br />5 <br />10 <br />' <br /> <br />- <br /> <br />7 <br />" <br />9' - 10" <br />1 <br />A4.1 <br />2 <br />A4.1 <br />1 1/2" MAX <br />THRESHOLD <br />3' - 6" <br />19 <br />' <br /> <br />- <br /> <br />6 <br />" <br />19' - 1" <br />NEW TANKLESS <br />WATER HEATER <br />WP <br />WP <br />WP <br />2 <br />2 <br />3 <br />C <br />8' - 8" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />D <br />WP WP <br />D <br />D <br />D <br />D <br />D <br />DD <br />D <br />D <br />CHECK AND VERIFY ALL DIMENSIONS  <br />BEFORE PROCEEDING WITH THE <br />WORK. REPORT DISCREPANCIES <br />TO THE ENGINEER. ALL CONSTRUCTION  <br />SHALL  CONFORM TO THE C.B.C.  <br />DESIGNER: <br />PROJECT: <br />CA <br />M <br />D <br />E <br />N <br /> RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />AD <br />D <br />I <br />T <br />I <br />O <br />N <br /> & RE <br />M <br />O <br />D <br />E <br />L <br />10 <br />3 <br />4 <br /> W CA <br />M <br />D <br />E <br />N <br /> PL <br />. <br />. <br />SA <br />N <br />T <br />A <br /> AN <br />A <br /> CA <br /> 92 <br />7 <br />0 <br />7 <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />MARK DATE REVISION <br />TITLE: <br />SHEET NUMBER <br />OF SHEETS <br />JOB NO. <br /> 24-401 <br />DRAWN: <br /> GH <br />CHEKED: <br /> GH <br />DATE: <br />APR-4-25 <br />71 <br />4 <br /> 63 <br />1 <br /> 24 <br />5 <br />8 <br />en <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br />d <br />m <br />g@ <br />o <br />u <br />l <br />o <br />o <br />k <br />. <br />c <br />o <br />m <br />3‐19‐25 <br />A2.2 <br />KEYNOTES <br />THE KEY NOTES DIRECTLY BELOW REFER <br />THE FLOOR PLAN ONLY <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />12 <br />11 <br />13 <br />14 <br />15 <br />16 <br />17 <br />18 <br />19 <br />20 <br />LEGEND <br />PLAN NOTES <br />NEW WALL <br />EXISTING WALL <br />DEMO WALL <br />SD <br />CO <br />SURFACE OR PENDANT MTD. LT. FIXTURE <br />(HIGH EFFICACY=ENERGY EFFICIENT) <br />DIMMABLE SINGLE POLE SWITCH <br />SMOKE DETECTOR 110VOLT, WITH BATTERY BACK UP <br />ALL SMOKE DETECTORS SHALL BE INTERCONNECTED <br />CARBON MONOXIDE DETECTOR <br />110 VOLT, WITH BATTERY BACK UP <br />WALL MTD. LT. FIXTURE (HIGH <br />EFFICACY) <br />DIMMABLE THREE WAY POLE SWITCH <br />WALL OUTLET 110 VOLTS <br />ALL OUTLETS SHALL BE TAMPERED RESISTANT TYP. <br />50 CFM TO EXHAUST MOISTURE OF THE BUILDING <br />MECHANICAL VENTILATION REQUIRED IN ALL BATHROOM <br />WITH TUB OR SHOWER <br />FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED <br />TO DETERMINATE TO THE OUTSIDE OF THE BUILDING. <br />FANS, NOT FUNCTIONING AS A COMPONENT OF A WHOLE <br />HOUSE VENTILATION SYSTEM, MUST BE CONTROLLED BY A <br />HUMIDITY CONTROL. <br />EXISTING <br />NEW <br />WINDOW TYPE PER SCHEDULE THIS SHEET <br />DOOR TYPE PER SCHEDULE THIS SHEET <br />NOTE PER KEYNOTES <br />(E) <br />(N) <br />A <br />6 <br />29 <br />3 <br />DOUBLE POLE SWITCH2 <br />OCCUPANCY SENSOR <br />D <br />D <br />1. PROVIDE ATTIC ACCESS OPENING (22"x30" MIN.) READILY <br />ACCESSIBLE WITH A 30" MIN. CLEAR HEAD ROOM ABOVE <br />ACCESS IN ALL ATTIC SPACES WITH A MINIMUM VERTICAL <br />HEIGHT OF 30". <br />2. ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLTS, SINGLE <br />PHASE, 15 & 20 AMPERE RECEPTACLE OUTLETS INSTALLED IN <br />BEDROOMS SHALL BE PROTECTED BY AN ARC-FAULTED <br />CIRCUIT INTERRUPTERS. <br />3. ACCES PANEL 12"x12" REQUIRED FOR TUB TRAP SLIP-JOINT <br />OR USE NON-SLIP (WELDED) JOINTS. <br />4. PROVIDE MECHANICAL VENTILATION CAPABLE OF PROVIDING <br />FIVE AIR CHANGES PER HOUR IN BATHROOMS. DUCTLESS <br />FANS ARE NOT ACCEPTABLE. THE POINT OF DISCHARGE <br />SHALL BE AT LEAST 3 FEET FROM ANY OPENING. <br />5. WATER CLOSETS (TOILETS) SHALL BE CERTIFIED TO USE A <br />MAXIMUM OF 1.28 GALLONS PER FLUSH. <br />6. SHOWER SHALL HAVE EITHER A PRESSURE VALVE BALANCE <br />OR A THERMOSTATIC MIXING VALVE. SHOWER HEADS SHALL <br />BE CERTIFIED TO USE A MAXIMUM OF 1.8 GALLONS PER <br />MINUTE. <br />7. SMOKE DETECTORS SHALL RECEIVE THEIR PRIMARY POWER <br />SOURCE FROM THE BUILDING WIRING AND SHALL BE <br />EQUIPPED WITH A BATTERY BACK-UP AND ALLOW BATTERY <br />SIGNAL. IN EXISTING CONSTRUCTION SMOKE DETECTORS <br />MAY BE BATTERY OPERATED. <br />8. IN A CLOSET, SURFACE MOUNTED LIGHTING FIXTURES SHALL <br />BE AT LEAST 18 INCHES FROM A STORAGE AREA AND FLUSH <br />MOUNTED LIGHTING FIXTURES SHALL BE AT LEAST 6 INCHES <br />FROM A STORAGE AREA. <br />9. GROUND-FAULT CIRCUIT-INTERRUPTER. (GFCI) PROTECTED <br />ELECTRICAL RECEPTACLES SHALL BE PROVIDED AT: <br />• ALL RECEPTACLES INSTALLED IN A BATHROOM. <br />• ALL RCEPTACLES INSTALLED IN A GARAGE. <br />• ALL OUTDOOR RECEPTACLES WHERE THERE IS DIRECT <br />GRADE LEVEL ACCESS. <br />10. BATHROOM RECEPTACLES SHALL BE SERVED BY DEDICATED <br />20 AMP.CIRCUIT. <br />11. SHOWER WALLS SHALL BE FINISHED WITH A SMOOTH HARD, <br />NON-ABSORBENT SURFACE SUCH AS PORTLAND CEMENT TILE <br />OR OTHER APPROVED MATERIAL. SUCH WALL FINISH SHALL <br />EXTEND TO A HEIGHT OF NOT LESS THAN 70 IN. ABOVE THE <br />DRAIN INLET. <br />12. LAZING IN DOORS AND WINDOWS SHALL BE PROVIDED WITH <br />TEMPERED GLASS AS REQUIRED IN U.B.C. CHAPTER 24 <br />INCLUDING GLAZING IN ANY PORTION OF A BUILDING WALL <br />AND GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM <br />EXPOSED EDGE OF TH GLAZING IS LESS THAN 60 INCHES <br />ABOVE A STANDING SURFACE AND DRAIN INLET; GLAZING IN <br />FIXED OR OPENABLE PANELS ADJACENT TO A DOOR WHERE <br />THE NEAREST EXPOSED EDGE TO THE GLAZING IS WITHIN A <br />24-INCH ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A <br />CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE <br />OF THE GLAZING IS LESS THAN 60 INCHES ABOVE THE <br />WALKING SURFACE. GLAZING IN WALLS ENCLOSING <br />STAIRWAYS LANDINGS OR WITHING 5 FEET OF THE BOTTOM <br />AND TOP OF STAIRWAYS WHERE THE BOTTOM EDGE OF THE <br />GLASS IS LESS THAN 60 INCHES ABOVE <br />FLOOR <br />PLAN <br />SCALE: 1/4" = 1'-0"1 FLOOR PLAN <br />XXXXHGGXHJ <br />WINDOW SHEDULE <br />MARK SIZE <br />WIDTHxHEIGHT <br />QUANTITY REMARKS <br />A 3'-0" x 4'-0" 2 <br />SLIDING DOUBLE <br />WINDOW TEMPERED <br />VINYL <br />B 3'-0" x 1'-6" 1 <br />DOOR SHEDULE <br />MARK SIZE <br />WIDTHxHEIGHT <br />QUANTITY REMARKS <br />3 5'-0" x 6'-8" 2 <br />60" DOUBLE SLIDING DOOR <br />2-PANEL WOOD <br />PAINTED WHITE <br />2 2'-8" x 6'-8" 5 <br />1 6'-0" x 6'-8" 1 <br />72" EXTERIOR DOUBLE DOOR <br />TEMPERED GLASS <br />VINYL <br />32" HOLLOW CORE DOOR <br />6-PANEL <br />PAINTED WHITE <br />STEP DETAIL1 <br />SLIDING DOUBLE <br />WINDOW TEMPERED <br />VINYL <br />C 6'-0" x 4'-0" 1 <br />SLIDING DOUBLE <br />WINDOW TEMPERED <br />VINYL <br />4 3'-6" x 6'-8" 1 <br />42" DOUBLE SLIDING DOOR <br />2-PANEL WOOD <br />PAINTED WHITE <br />60" INTERIOR BIFOLD DOOR <br />4-PANEL LOUVERED WOOD <br />PAINTED WHITE <br />5 5'-0" x 6'-8" 1 <br />D 4'-0" x 4'-0" 1 <br />SLIDING DOUBLE <br />WINDOW TEMPERED <br />VINYL <br />U-FACTOR SHGC <br /> 0.3 0.23 <br /> 0.23 <br /> 0.23 <br /> 0.23 <br /> 0.3 <br /> 0.3 <br /> 0.3