Laserfiche WebLink
Harbor Logistics Center <br />SOLAR SOURCE INC 2954 E 14TH <br />ST, LONG BEACH, CA 90804 <br />LIC#: 925231, CLASS - C46, C10 <br />License Date 03/31/2025 <br />3100 S Harbor Blvd, <br />Santa Ana, CA 92704 <br />Date: September 18, 2024 <br />Project Information <br />01-A-050 <br />SHEET INDEX <br />02-E-001 <br />03-E-002 <br />04-S0.1 <br />05-K-003 <br />Plot Plan <br />Stringing <br />Single line diagram <br />Array Layout <br />Signage <br />00-G-000 Cover Sheet <br />06-K-004 Stickers <br />07-K-005 <br />08-K-006 <br />09-K-007 <br />Datasheet <br />Datasheet <br />Datasheet <br />010-K-008 Datasheet <br />011-K-009 Datasheet <br />012-K-0010 Datasheet <br />013-K-0011 Datasheet <br />#3/0 FACILITY <br />GROUND <br /> 2000AMP <br />NON CENTER <br />MAIN BREAKER <br /> MAIN SERVICE PANEL 277/480V, <br /> 3 PHASE SERVICE <br /> MAIN PANEL BUS <br /> MAIN BREAKERS <br />UTILITY <br />METER <br />8' minimum embedment rod at 6' <br />from equipment ground conductor unless <br />existing ground is UFER. <br />4000A <br />4000A <br />1x2000A 1x600A <br />Existing <br />Existing <br />AC DISCONNECT <br />60A UNFUSED <br />NEMA 3R <br />lockable, visible <br />3 PHASE 277/480V <br />INSTALL 40A END OF <br />BUS FROM MAIN C/B <br />480V SOLAR SYSTEM <br />30.5*1.25=38.125Amp(480V) <br />Total 480V 38.125A <br />EXISTING MAIN SERVICE PANEL 480V 3 PHASE <br />BUS-2000A <br />MAIN BREAKER-2000A <br />120% CALCULATION-2000*1.2-2000=400A > 38.125A PV <br />INTEGRATED <br />DC DISCONNECT <br />MAX INPUT: 45A, 1000Vdc <br />SOLECTRIA <br />PVI-25TL-480 <br />GRID TIED 25,000W INVERTER <br />AC MAX OUTPUT CURRENT: 30.5A <br />AC <br />OUT <br />DC <br />IN <br />3/4" EMT CONDUIT <br />(4) #8 AWG THWN-2 Conductors <br />(1) #8 AWG THWN-2 Ground <br />J BOX <br />NEMA 3R <br />WIRES EXPOSED TO FREE AIR UNDER ARRAY <br />(2) #12 AWG Conductors <br />(1) #6 AWG Bare Copper Ground <br />STRING #1 <br />STRING #2 <br />3/4" EMT CONDUIT <br />(8) #10 AWG THWN-2 Conductors <br />(1) #8 AWG THWN-2 Ground <br />STRING #3 <br />STRING #4 <br />600AMP <br />NON CENTER <br />MAIN BREAKER <br />UTILITY <br />METER <br />4000A <br />3/4" EMT CONDUIT <br />(4) #8 AWG THWN-2 Conductors <br />(1) #8 AWG THWN-2 Ground <br />Longi LR5-72HBD-545M Longi LR5-72HBD-545M <br />Longi LR5-72HBD-545M <br />Longi LR5-72HBD-545M <br /> 11 <br /> 11 <br /> 11 <br /> 11 <br />03-E-002-SLD <br />1)Equipment is "New" unless otherwise noted. <br />All PV system wires shall be protected against physical damage <br />2)Terminations shall be rated 75 degree <br />3)MINIMAL CONDUCTOR HEIGHT TO BE 7/8" ABOVE THE ROOF <br />SURFACE <br />PV PANEL AND EQUIPMENT MODEL NUMBER,QUANTITY ADDITIONAL NOTES <br />STRING <br />#1 <br />STRING <br />#2 <br />STRING <br />#3 <br />STRING <br />#4 <br />3100 S Harbor Blvd <br />1/27/2025