Laserfiche WebLink
Page 5 of 8 <br />1760 Chicago Ave Ste J13, Riverside, CA 92507 (951) 405-1733 info@currentrenewableseng.com <br />Roof Framing Checks: <br />Force Checks <br />LC1: D+S Check 1 <br />Applied Moment (lb-ft):300.8 <br />Applied Shear (lbs):108.6 <br />Allowable Moment (lb-ft):975.1 <br />Allowable Shear (lbs):1,138.5 <br />Moment DCR:0.309 <br />Shear DCR:0.095 <br />LC2: D+0.6W Check 1 <br />Applied Moment (lb-ft):591.2 <br />Applied Shear (lbs):213.4 <br />Allowable Moment (lb-ft):1,356.7 <br />Allowable Shear (lbs):1,584.0 <br />Moment DCR:0.436 <br />Shear DCR:0.135 <br />LC3: D+0.75(S+0.6W)Check 1 <br />Applied Moment (lb-ft):518.6 <br />Applied Shear (lbs):187.2 <br />Allowable Moment (lb-ft):1,356.7 <br />Allowable Shear (lbs):1,584.0 <br />Moment DCR:0.382 <br />Shear DCR:0.118 <br />LC4: 0.6D+0.6W Check 1 <br />Applied Moment (lb-ft):470.9 <br />Applied Shear (lbs):169.9 <br />Allowable Moment (lb-ft):1,356.7 <br />Allowable Shear (lbs):1,584.0 <br />Moment DCR:0.347 <br />Shear DCR:0.107 <br />1727 W Pine St <br />Unit# 210/15/2024