My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1727 W Pine St Unit# 2 - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Pine St
>
1727 W Pine St Unit# 2
>
1727 W Pine St Unit# 2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2025 12:44:32 PM
Creation date
6/15/2025 12:44:05 PM
Metadata
Fields
Template:
Plan
Permit Number
20184200
101121112
Full Address
1727 W Pine St Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 8 of 8 <br />1760 Chicago Ave Ste J13, Riverside, CA 92507 (951) 405-1733 info@currentrenewableseng.com <br />Limits of Scope of Work and Liability: <br />Existing structure is assumed to have been designed and constructed following appropriate <br />codes at time of erection, and assumed to have appropriate permits. The calculations <br />produced are only for the roof framing supporting the proposed PV installation referenced in <br />the stamped planset and were completed according to generally recognized structural <br />analysis standards and procedures, professional engineering and design experience, <br />opinions and judgements. Existing deficiencies which are unknown or were not observable <br />during time of inspection are not included in this scope of work. All PV modules, racking, and <br />mounting equipment shall be designed and installed per manufacturer's approved <br />installation specifications. The Engineer of Record and the engineering consulting firm <br />assume no responsibility for misuse or improper installation. This analysis is not stamped for <br />water leakage. Framing was determined based on information in provided plans and/or <br />photos, along with engineering judgement. Prior to commencement of work, the contractor <br />shall verify the framing sizes, spacings, and spans noted in the stamped plans, calculations, <br />and cert letter (where applicable) and notify the Engineer of Record of any discrepancies <br />prior to starting construction. Contractor shall also verify that there is no damaged framing <br />that was not addressed in stamped plans, calculations, and cert letter (where applicable) <br />and notify the Engineer of Record of any concerns prior to starting construction. <br />1727 W Pine St <br />Unit# 210/15/2024
The URL can be used to link to this page
Your browser does not support the video tag.