October 1, 2013 SIGN COMPONENTS MANUAL (SAM) 76
<br />7. A temperature test is not required if the LED drivers are spaced at least 1 in. apart end to end or 4 in. apart in other directions.
<br />Spacng to plastic shall be 1 inch minimum and to metal may be zero in. The need for a temperature test shall be considered if
<br />the LED driver is mounted closer than the referenced spacings. For reference these LED drivers have been tested in a 50 C
<br />ambient and maximum case temperature is 73C.
<br />JKL COMPONENTS CORP
<br />13343 PAXTON ST
<br />E339601
<br />PACOIMA, CA 91331
<br />Class 2 LED Modules, designated as ZAF-336-24, ZAF-486-24, ZAF-636-24, ZAF-936-24, ZAF-1236-24; may be followed by
<br />additional suffixes for color temperature.
<br />1. These products are only suitable for connection to a Class 2 power source rated 24 Volt DC or less.
<br />2. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy
<br />limited circuit and is rated greater than 24V DC.
<br />3. When these units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or
<br />output rating of the Class 2 supply.
<br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 24 Volts DC or less.
<br />5. These products are not required to be enclosed or protected from the weather in the end product.
<br />6. These products may be secured in place in the end product by any means
<br />LED Illumination Modules, ZM-4047-CW, ZM-1957-CW, ZM-1543-R.
<br />1. Each Class 2 LED Modules is only suitable for connection to a Class 2 power source, max. 24 Volt dc or less.
<br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2
<br />voltage and energy limits.
<br />3. Class 2 LED modules, rated max. 12 Watts per LED unit or less. When units are connected to a Class 2 circuit, they are not
<br />to draw a total wattage of greater than the secondary or output rating of the Class 2 supply.
<br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated at max. 24 Volt DC or less.
<br />5. These products are not required to be enclosed or protected from the weather in the end product.
<br />Class 2 LED Modules, Cat. No. ZWF-XXXX-XX, where XXXX-X)< will be replaced with alpha-numeric digits that indicated
<br />length and color.
<br />1. These Class 2 LED modules are only suitable for connection to a Class 2 power source, rated 15 Volt or less.
<br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2
<br />voltage and energy limits.
<br />3. These Class 2 LED modules are rated max. 2 Watts per LED module. When these units are connected to a Class 2 circuit,
<br />they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply.
<br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated at max. 15 Volts or less,
<br />5. These products are not required to be enclosed or protected from the weather in the end product.
<br />Class 2 LED Modules, Cat. No. ZWF-337-24CW, ZWF-438-24CW, ZWF-638-24CW, ZWF-939-24CW, ZWF-1239-24CW,
<br />ZWF-337-24VWV, ZWF-438-24VWV, ZWF-638-24VWV, ZWF-939-24VWV, ZWF-1239-24\/WV.
<br />1. Each Class 2 LED Module is only suitable for connection to a Class 2 power source, max. 24 Volt dc or less.
<br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2
<br />voltage and energy limits.
<br />3. Class 2 LED modules rated max. 12 Watts per LED unit or less. When units are connected to a Class 2 circuit, they are not
<br />to draw a total wattage of greater than the secondary or output rating of the Class 2 supply.
<br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated at max. 24 Volt DC or less.
<br />5. These products are not required to be enclosed or protected from the weather in the end product.
<br />JOHNSON WALKER & ASSOCIATES L LC, DBA IMPERIAL PLASTICS MFG E225580
<br />4337 MILL ST
<br />NORTH BRANCH, MI 48461
<br />Aluminum Reinforced Sign Face Trim, designated Signatrim.
<br />1. Acceptable for use in dry, damp and wet locations.
<br />2. Water exclusion must be determined in the end product.
<br />3. Minimum 5 cm (2 in.) spacing from heat producing components required.
<br />4. The specified solvents are continuously applied to edge of acrylic or polycarbonate sign face. Additional specified adhesives
<br />may be applied for the final bond.
<br />Sign Face Generic Material Solvent Final Bond Adhesive Sign Trim Generic Material
<br />Methyl Methacrylate (Acrylic)Methylene Chloride Methylene Chloride Cellulose Acetate Butyrate
<br />Methyl Methacrylate (Acrylic)Weld-ON #4 Weld-ON # 16 Cellulose Acetate Butyrate
<br />Methylene Chloride
<br />Polycarbonate Transco Transco Cellulose Acetate Butyrate
<br />Channel Bond Channel Bond
<br />5. The suitability of the securement or ':fit" of this trip cap shall be determined in the end product. Screws or solvents are
<br />considered acceptable for permanent mounting.
<br />" JS LED TECHNOLOGY CORP, DBA JS LED POWER INC E308859
<br />1318 MAINE AVE
<br />BALDWIN PARK, CA 91706
<br />Class 2 LED Modules, Cat. No. JE-00ABCD-XY-EZ Series, where A, B, C, D, E, Z, X and Y may be any alphanumeric characters,
<br />or suffixes may be blank.
|