Laserfiche WebLink
PAGE <br />REV: B1 6/3/2025 <br />DIANE LE <br />3428 S CRAWFORD GLEN,  <br />SANTA ANA, CA, 92704 <br />PROJECT NUMBER: <br />  109R-428LE <br />SHEET <br />DESIGNER: <br />NITHYA L <br />CUSTOMER RESIDENCE: <br />TEL. (714) 603-8822 <br />APN: 412-531-02 <br />(415) 580-6920 ex3 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603   <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />NOMINAL ESS VOLTAGE VAC <br />LABEL LOCATION: <br />ENERGY STORAGE SYSTEM <br />PER CODE(S): 2020 NEC 706.15(C), 2022 CEC 706.15(C) <br />120 240 <br />520 VDCMAXIMUM ESS DC VOLTAGE:60 <br />ENERGY STORAGE SYSTEM DISCONNECT <br />ENERGY STORAGE SYSTEM <br />PREMISES WIRING MAY REMAIN  <br />ENERGIZED AFTER LOSS OF  <br />UTILITY POWER <br />CAUTION! <br />LABEL LOCATION: <br />INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C) <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br />          48 AMPS <br />  240     VAC <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF  <br />INTERCONNECTION. <br />PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 <br />PV SYSTEM DISCONNECT <br />WARNING! <br />DO NOT RELOCATE THIS  <br />OVERCURRENT DEVICE <br />POWER SOURCE OUTPUT CONNECTION <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER AND ESS  <br />OCPD (IF APPLICABLE). <br />PER CODE(S): NEC 2020: 705.12(B)(3)(2),  <br />CEC 2022: 705.12(B)(3)(2) <br />NOTES AND  <br />SPECIFICATIONS:  <br /> SIGNS AND LABELS SHALL MEET THE  <br />REQUIREMENTS OF THE CEC 2022 ARTICLE  <br />110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE  <br />REQUIRED BY SECTION 690, OR IF REQUESTED  <br />BY THE LOCAL AHJ. <br /> SIGNS AND LABELS SHALL ADEQUATELY WARN  <br />OF HAZARDS USING EFFECTIVE WORDS,  <br />COLORS AND SYMBOLS. <br /> LABELS SHALL BE PERMANENTLY AFFIXED TO  <br />THE EQUIPMENT OR WIRING METHOD AND  <br />SHALL NOT BE HAND WRITTEN. <br /> LABEL SHALL BE OF SUFFICIENT DURABILITY TO  <br />WITHSTAND THE ENVIRONMENT INVOLVED. <br /> SIGNS AND LABELS SHALL COMPLY WITH ANSI  <br />Z535.4-2011, PRODUCT SAFETY SIGNS AND  <br />LABELS, UNLESS OTHERWISE SPECIFIED. <br /> DO NOT COVER EXISTING MANUFACTURER  <br />LABELS. <br />SOLAR PV SYSTEM EQUIPPED  <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC  <br />PV PANELS <br />TURN RAPID SHUTDOWN  <br />SWITCH TO THE "OFF"  <br />POSITION TO SHUT DOWN  <br />PV SYSTEM AND REDUCE  <br />SHOCK HAZARD IN THE  <br />ARRAY. <br />LABEL LOCATION: <br />ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE  <br />DISCONNECTING MEANS TO WHICH THE PV SYSTEMS  <br />ARE CONNECTED. <br />PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) <br />4" <br />3" <br />ELECTRICAL SHOCK HAZARD <br />WARNING <br />TERMINALS ON LINE AND LOAD  <br />SIDES MAY BE ENERGIZED IN  <br />THE OPEN POSITION <br />LABEL LOCATION: <br />INVERTER(S),  AC/DC DISCONNECT(S),  <br />AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): NEC 2020: 690.13(B), CEC  <br />2022: 690.13(B) <br />! <br />INVERTER 1 <br />PHOTOVOLTAIC DC DISCONNECT <br />MAXIMUM SYSTEM VOLTAGE:VDC550 <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECT(S). <br />PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 <br />WARNING: PHOTOVOLTAIC  <br />POWER SOURCE <br />WARNING: PHOTOVOLTAIC  <br />POWER SOURCE <br />LABEL LOCATION: <br />INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,  <br />AT EACH TURN, ABOVE AND BELOW  PENETRATIONS,  <br />ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. <br />PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022:  <br />690.31(D)(2) <br />LABEL LOCATION: <br />INSTALLED WITHIN 3' OF RAPID SHUT DOWN  <br />SWITCH PER CODE(S): NEC 2020: 690.56(C)(2),  <br />CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 <br />RAPID SHUTDOWN SWITCH  <br />FOR SOLAR PV SYSTEM <br />WARNING! <br />SOURCES: UTILITY GRID,  <br />BATTERY AND PV SOLAR  <br />ELECTRIC SYSTEM <br />THREE POWER SUPPLY <br />LABEL LOCATION: <br />UTILITY SERVICE METER AND MAIN  <br />SERVICE PANEL. <br />PER CODE(S): NEC 2020: 705.12(C), CEC  <br />2022: 705.12(C) <br />THIS EQUIPMENT FED BY  <br />MULTIPLE SOURCES. TOTAL  <br />RATING OF ALL OVERCURRENT  <br />DEVICES EXCLUDING MAIN  <br />SUPPLY OVERCURRENT DEVICE  <br />SHALL NOT EXCEED AMPACITY OF  <br />BUSBAR <br />WARNING! <br />LABEL LOCATION: <br />PV LOAD CENTER (IF APPLICABLE) AND  <br />ANY PANEL THAT UTILIZES "THE SUM  <br />OF BREAKERS RULE". <br />PER CODE(S): NEC 2020: 705.12 (B)(3)(3),  <br />CEC 2022: 705.12 (B)(3)(3) <br />INVERTER 2 <br />PHOTOVOLTAIC DC DISCONNECT <br />MAXIMUM SYSTEM VOLTAGE:VDC550 <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECT(S). <br />PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 <br />MAXIMUM AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br />          48 AMPS <br />  240     VAC <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF  <br />INTERCONNECTION. <br />PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 <br />PV SYSTEM DISCONNECT <br />WARNING: THIS SENSOR IS PART  <br />OF A POWER CONTROL SYSTEM.  <br />DO NOT REMOVE. REPLACE ONLY  <br />WITH THE SAME TYPE AND RATING. <br />WARNING: THIS SENSOR IS PART  <br />OF A POWER CONTROL SYSTEM.  <br />DO NOT REMOVE. REPLACE ONLY  <br />WITH THE SAME TYPE AND RATING. <br />REQUIREMENT: UL 1741, SECTION 206.3 <br />LOCATION: AROUND THE CT WIRE  BY CLAMP <br />SIZE 4.25" X 0.75" <br />INVERTER 1 & 2 <br />LABEL LOCATION: <br />REQUIREMENT: UL 1741, SECTION 206.1 AND 206.4 <br />LOCATION: MAIN PANEL <br />SIZE: 4.25" X 1.25" <br />PCS CONTROLLED CURRENT SETTING:  80 A  <br />THE MAXIMUM OUTPUT CURRENT FROM THIS <br />SYSTEM IS CONTROLLED ELECTRONICALLY. <br />REFER TO THE MANUFACTURER'S <br />INSTRUCTIONS FOR MORE INFORMATION. <br />PV-5.0 <br />SIGNAGE