Laserfiche WebLink
EXISTING BASE SHEAR <br />V = 0.185 x 21,000 LBS = 3,885 LBS <br />DETERMINE NEW BASE SHEAR <br />Determine Seismic Weight of Building with Solar Array: <br />EXISTING <br />SEISMIC =21,000 LBS <br />WEIGHT <br />NEW SOLAR <br />ARRAY =3 PSF x 9 PANELS x 5.5' x 3.3' = 491 LBS <br />NEW <br />SEISMIC =21,000 LBS + 491 LBS = 21,491 LBS <br />WEIGHT <br />THEREFORE NEW BASE SHEAR: <br />V = 0.185 x 21,491 = 3,976 LBS EQ'N 12.8-1 ASCE 7-16 <br />OK. PER ASCE 7-16 SECTION 11B.4 ALTERATIONS <br />EXISTING LATERAL FORCE RESISTING SYSTEM IS EXEMPT <br />FROM ANALYSIS SINCE NEW SEISMIC FORCE IS <br />LESS THAN 10% GREATER THAN EXISTING SEISMIC FORCE <br />Sht # 7 of 7 <br />2025-0845 Smart House Francisco Gutierrez April 1, 2025 <br />      Loyd W. Martin Professional Engineer, Inc.       <br />9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 <br />"Alterations may be made to any structure without requiring the existing structure to comply <br />with this standard, provided that the alterations comply with the requirements for a new <br />structure. Alterations that increase the seismic force in any existing structural element by <br />more than 10% or decrease the design strength of any existing structural element to resist <br />seismic forces by more than 10% shall not be permitted unless the entire seismic force- <br />resisting system is determined to comply with this standard for a new structure." <br />End of Calculations <br /> Email: loydwmartin@gmail.com www.loydwmartin.com <br />% CHANGE =3,976 LBS - 3,885 LBS x 100 = 2.3 % < 10 % OK3,885 LBS <br />Exp. 3-31-19 <br />C L <br />­2187