My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1218 W Cubbon St #2 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Cubbon St
>
1218 W Cubbon St Unit# 2
>
1218 W Cubbon St #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/3/2025 5:00:08 AM
Creation date
7/3/2025 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
20186247
101124171
Full Address
1218 W Cubbon St Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FR <br />A <br />N <br />C <br />I <br />S <br />C <br />O <br /> <br />G <br />U <br />T <br />I <br />E <br />R <br />R <br />E <br />Z <br />12 <br />1 <br />8 <br /> <br />W <br /> <br />C <br />U <br />B <br />B <br />O <br />N <br /> <br />S <br />T <br /> <br /># <br />2 <br />, <br /> <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />, <br /> <br />U <br />S <br />A <br />REVDATEDESCRIPTION <br />REVISIONS <br />HOMEOWNER INFO <br />AP <br />N <br />: <br /> <br />0 <br />1 <br />0 <br />2 <br />7 <br />2 <br />0 <br />7 <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />PV-6 <br />SIGNATURE & SEAL <br />CONTRACTOR: MY SMART HOUSE <br />ADDRESS: 39809 AVENIDA ACACIAS, UNIT D <br />MURRIETA, CA 92563 <br />PHONE: 8884453020 <br />LICENSE #: C-10 1095569 <br />JOSE EMILIO BAHENA <br />WIRING <br />CALCULATION <br />WIRING CALCULATIONS <br />SCALE: NTS <br />SOLAR MODULE SPECIFICATIONS <br />MANUFACTURER / MODEL APTOS SOLAR DNA-120-MF10-440W <br />(440W) SOLAR MODULES <br />VMP 33.72V <br />IMP 13.05A <br />VOC 41.02V <br />ISC 13.73A <br />TEMP. COEFF. VOC -0.27%/°C <br />MODULE DIMENSION 75.1(L) x 44.6(W) <br />PANEL WATTAGE 440W <br />Inverter Ratings <br />Inverter Make/Model <br />ENPHASE <br />ENERGY INC. <br />IQ8PLUS-72-M-US <br />[240V] <br />Max DC Volt Rating 60V <br />Max con output Power 290W <br />Max Nominal Voltage 240V <br />Max AC Current 1.21A <br />Max OCPD Rating 20A <br />EXTREME CASE MODULE OUTPUT <br />(APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES) <br />Isc(25°C) = 13.73A, Tisc = 0.054%/°C <br />Isc(T) = Isc(25°C) x [1 + (0.054/100) x (T-25°C)] <br />Isc(-2°C) = 13.53A, Isc(31°C) = 13.77A <br />Voc(25°C) = 41.02V, Tvoc = -0.27%/°C <br />Voc(T) = Voc(25°C) x [1 + (-0.27/100) x (T-25°C)] <br />Voc(-2°C) = 44.01V, Voc(31°C) = 40.36V <br />● 1X BRANCH OF 9 CONNECTED IN PARALLEL <br />SYSTEM SUMMARY STC (3.960 kW DC / 2.610 kW AC) <br />STC DC:(9) 440W = 3.960 kW <br />STC AC:(9) 290W = 2.610 kW <br />●(9) - APTOS SOLAR DNA-120-MF10-440W (440W) SOLAR MODULES <br />● (9)- ENPHASE ENERGY INC. IQ8PLUS-72-M-US [240V] MICROINVERTER <br />ELECTRICAL NOTES <br />1) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. <br />2) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600V AND 90°C WET ENVIRONMENT. <br />3) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY <br />WITH NEC 110.26. <br />4) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH <br />ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES <br />AND STANDARDS. <br />5) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE <br />CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br />6) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br />7) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT <br />RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. <br />8) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO <br />GBL-4DBT LAY-IN LUG. <br />9) PV EQUIPMENT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NEC 690. <br />10) EXACT LOCATION OF AUXILIARY GROUNDING TO BE DETERMINED AT TIME OF INSTALL. <br />11) EXISTING WIRES MUST BE REPLACED IF SMALLER THAN LISTED MINIMUM SIZES PER NEC <br />310.15(B)(16). <br />12) IQ GATEWAY BREAKER DETERMINED AT FACTORY BY MANUFACTURER (10A or 15A). <br />13) IQ COMBINER 5/5C REQUIRES ENPHASE HOLD DOWN KIT X-IQ-NA-HD-125A. <br />AC wire details <br /> Tag Nominal <br />Voltage <br />Expected <br />max temp <br />Adjusted ampacity (ampacity x temp <br />derate x conduit fill derate) <br />Conductor & <br />neutral size <br />A 30 x 1 x 1 = 30.00 A 12 AWG (Q-Cable) <br />10 AWG THWN-2 <br />#Modules <br />9 <br />91 240 V <br />240 V <br />Backfeed *1.25 <br />/cond.set <br />13.61 A <br />Min <br />OCPD <br />13.61 A <br />20 A <br />20 A <br />Conductor <br />sets <br />1 <br />1 <br />ccConductors <br />/conduit <br />- <br />2 <br />31 <br />Conductor <br />metal <br />Cu <br />Cu <br />Max <br />length <br />30 ft <br />15 ft <br />V drop Min EMT/PVC <br />size <br />0.47 <br />0.15 <br />EGC size <br />(Cu) <br />06 AWG BARE <br />(NOT IN CONDUIT) <br />10 AWG THWN-2 <br />- <br />3/4 in EMT31 <br />10 AWG THWN-22240 V 12.10 A 20 A 1 2 Cu 15 ft10 AWG THWN-2 3/4 in EMT31 <br />35 x 1 x 1= 35.00 A <br />35 x 1 x 1 = 35.00 A9 0.15
The URL can be used to link to this page
Your browser does not support the video tag.