Laserfiche WebLink
GENERAL NOTES <br />A.SEE INTERIOR FINISH SCHEDULE FOR ALL CEILING FINISHES. <br />B.DO NOT SCREW THE CEILING GRID TO THE STAINLESS STEEL HOODS. REFER TO <br />DETAIL 2/A1.2. <br />C.REFER TO ELECTRICAL AND/OR HVAC DRAWINGS FOR ADDITIONAL INFORMATION <br />REGARDING ALL FIXTURES, DEVICES AND EQUIPMENT SHOWN ON THIS PLAN. <br />D.VERIFY CONFIGURATION OF MUSIC SYSTEM IN DINING ROOM. COORDINATE <br />REQUIREMENTS WITH WENDY'S I.T. CONTACT. <br />E.VERIFY CONFIGURATION OF WIFI SYSTEM. COORDINATE REQUIREMENTS WITH <br />WENDY'S I.T. CONTACT. <br />F.ALL LIGHT FIXTURES MOUNTED IN CEILING TILES ARE TO BE CENTERED IN THE <br />TILE U.N.O. <br />G.USE ALTERNATE MATERIAL BELOW ROOFING DECK INSTEAD OF TECTUM <br />#CODED NOTES: <br />1.EXPOSED STRUCTURAL OPEN WEB TRUSSES PAINT P12. INSTALL 1/2 " ZINTRA SLATE <br />PANELING ZTR4706 ACOUSTICAL PANELS OVER EXITING DECK.. <br />2.TRACK LIGHTS. TRACK TO BE MOUNTED AT 12'-0" AF.F. REFER TO ELECTRICAL <br />DRAWINGS FOR FIXTURE INFORMATION. <br />3.LIGHT FIXTURES IN PICK UP WINDOW CANOPY. REFER TO ELECTRICAL DRAWINGS. <br />4.SPEAKER. PROVIDE BLOCKING AS REQUIRED. <br />5.EXHAUST HOODS. REFER TO MECHANICAL DRAWINGS. <br />6.G.C. TO PROVIDE AND INSTALL LIGHTING FOR COOLER/FREEZER/RECEIVING UNITS W/ <br />MOTION SENSOR. <br />7.REFER TO EXTERIOR ELEVATIONS FOR MOUNTING LOCATIONS OF WALL MOUNTED <br />LIGHT FIXTURES (TYP.). <br />8.CONT. 2" VENT SCREED. <br />9.PAINT WALLS ABOVE 11'-6" (ABOVE TRIM), EXPOSED STRUCTURE, CONDUITS, J-BOXES, <br />WIRING, PIPING, DUCTS AND REGISTERS , W/ PAINT INDICATED ON FINISH PLAN. <br />10.PENDANT LIGHTING, BOTTOM OF FIXTURE TO BE ALIGNED WITH B.O. TRUSSES. <br />REFER TO ELECTRICAL DRAWINGS. <br />11.EQUIPMENT CHASE. REFER TO ELECTRICAL AND MECHANICAL DRAWINGS. <br />12.EXTEND GYP. BD. TIGHT TO DECK ABOVE. <br />13.FREEZER/COOLER EVAPORATOR, REFER TO MECHANICAL DRAWINGS. <br />14.PATIO HEATERS. REFER TO ELECTRICAL DRAWINGS. PATIO HEATER, LOCATIONS TO <br />BE FIELD COORDINATED TO MEET MANUFACTURER'S CLEARANCE REQUIREMENTS TO <br />COMBUSTIBLES. <br />15.JOIST BRIDGING, REFER TO STRUCTURAL DRAWINGS. <br />16.BOX CHANDELIER TO BE MOUNTED AT 6'-8" A.F.F. & CENTERED OVER TABLE BELOW. <br />PROVIDE BLOCKING AS REQUIRED. REFER TO ELECTRICAL DRAWINGS. <br />17.MONO POINT SPOT LIGHT FIXTURE TO BE MOUNTED AT BOTTOM OF JOIST & <br />CENTERED ON TABLES BELOW. PROVIDE BLOCKING AS REQUIRED. REFER TO <br />ELECTRICAL DRAWINGS <br />18.PENDANT GLOBE LIGHT TO BE MOUNTED AT 6'-0" A.F.F. CENTERED OVER TABLE <br />U.N.O. REFER TO ELECTRICAL DRAWINGS AND INTERIOR ELEVATIONS <br />19.LED STRIP LIGHT AT CORNICE/PARAPET CAP. REFER TO ELECTRICAL DRAWINGS. <br />20.MAIN DUCT TO BE 2" BELOW BOTTOM OF JOIST <br />21.SPEAKER. <br />22.PATIO STRING LIGHTS, REFER TO ELECTRICAL. <br />23.SURFACE MOUNTED PATIO CEILING LIGHT, REFER TO ELECTRICAL. <br />24.SURFACE MOUNTED PATIO BLADE LIGHT, REFER TO ELECTRICAL. <br />25.ALL EXPOSED STRUCTURE, CONDUITS, J-BOXES, AND WIRING, TO BE PAINTED <br />PEX-12. REFER TO FINISH PLAN. <br />26.STAINLESS STEEL CHASE TIED INTO UNDERSIDE OF SOFFIT FOR DRINK LINES BY KED. <br />27.DRAFT STOP AT 20'-0" MAX. INTERVALS HORIZONTALLY. AT BRACING TYP. <br />28.METAL CANOPY/AWNING. HEAT TRACE, SUPPLY AND INSTALLED BY G.C., REFER TO <br />EXTERIOR ELEVATIONS AND WALL SECTIONS <br />STRING LIGHT <br />CELING MOUNTED <br />HEATER <br />LED LIGHT <br />FIXTURE <br />EMERGENCY <br />EGRESS LIGHT <br />WIB LIGHT <br />LEGEND <br />SUSPENDED <br />LIGHT FIXTURE <br />DIRECTIONAL <br />TRACK LIGHT <br />AIR DIFFUSERS <br />SW SUB WOOFER <br />SPEAKER <br />DIRECTIONAL LIGHT <br />RECESSED CAN LIGHT <br />EXIT LIGHT <br />SP SP <br />LED TAPE LIGHT <br />EMERGENCY LIGHT NOTE: <br />THE POWER SUPPLY FOR MEANS OF <br />EGRESS ILLUMINATION SHALL <br />NORMALLY BE PROVIDED BY THE <br />PREMISES ELECTRICAL SUPPLY. IN THE <br />EVENT OF POWER SUPPLY FAILURE, <br />THE EMERGENCY POWER SYSTEM <br />SHALL PROVIDE POWER FOR A <br />DURATION OF NOT LESS THAN 90 <br />MINUTES AND SHALL CONSIST OF <br />STORAGE BATTERIES, UNIT EQUIPMENT <br />OR AN ON-SITE GENERATOR. BUILDING <br />CODE 1006.3 <br />SP SP <br />SP <br />SP <br />SPSP <br />CEILING GRID AND ACT (CT-1) <br />CEILING GRID AND WASHABLE ACT <br />(CT-4) <br />CEILING GRID AND ACT (CT-2) <br />CEILING GRID AND WASHABLE, <br />NON-COMBUSTIBLE CLG. TILE (CT-5) <br />FIRE DEPT. NOTES <br />1.THE MEANS OF EGRESS, AND EXIT DISCHARGE, <br />SHALL BE ILLUMINATED AT ANY TIME THE <br />BUILDING IS OCCUPIED WITH A LIGHT INTENSITY <br />OF NOT LESS THAN 1 FOOT-CANDLE AT THE <br />WALKING SURFACE LEVEL. BUILDING CODE <br />1006.2. <br />2.EGRESS DOORS SHALL BE READILY OPENABLE <br />FROM THE EGRESS SIDE WITHOUT THE USE OF A <br />KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. <br />BUILDING CODE 1008.1.9. <br />3.EXITS, EXIT ACCESS DOORS AND PATHS OF <br />EGRESS TRAVEL THAT IS NOT IMMEDIATELY <br />VISIBLE TO THE OCCUPANTS SHALL BE MARKED <br />BY AN APPROVED EXIT SIGN THAT IS READILY <br />VISIBLE FROM ANY DIRECTION OF EGRESS <br />TRAVEL. EXIT SIGNS SHALL BE INTERNALLY OR <br />EXTERNALLY ILLUMINATED. BUILDING CODE 1011. <br />5'-0"5'-0"5'-0"5'-0"5'-0" <br />DINING <br />101 <br />42 SEATS <br />EQ <br />. <br />EQ <br />. <br />01 REFLECTED CEILING PLAN <br />SCALE: 1/4" = 1'-0" <br />5 <br />A4.5 <br />4 <br />A4.5 <br />3 <br />A4.5 <br />2 <br />A4.5 <br />1 <br />A4.5 <br />6 <br />A4.5 <br />19 <br />19 <br />77 <br />19 9 <br />3 <br />5 <br />27 <br />6 6 <br />7 7 19 <br />5 <br />27 <br />27 <br />16 <br />18 <br />4 <br />19 <br />2 <br />4 <br />4 <br />4 <br />19 <br />19 <br />19 <br />CT-1 <br />9'-0" <br />CT-4 <br />9'-6" <br />WT-8 <br />9'-4" <br />5 <br />A4.5 <br />4 <br />A4.5 <br />3 <br />A4.5 <br />2 <br />A4.5 <br />1 <br />A4.5 <br />6 <br />A4.5 <br />CT-4 <br />10'-0" <br />CT-5 <br />8'-0" <br />CT-1 <br />8'-0" <br />2 <br />AC <br />1 <br />AC <br />1 <br />1 <br />1 <br />SD-4 <br />100 <br />SD-4 <br />100 <br />6"Ø <br />6" <br />Ø <br />8"Ø <br />RETURN PLENUM <br />SD-5 <br />311 <br />SD-5 <br />311 <br />SD-5 <br />311 <br />SD-5 <br />311 <br />SD-5 <br />311 <br />5 <br />14 <br />" <br />X <br />1 <br />4 <br />" <br />4RTU-1 <br />S <br />16 <br />" <br />X <br />2 <br />0 <br />" <br />RG-1 <br />-900 <br />RG-1 <br />-900 <br />RTU-1 <br />SD-5 <br />311 <br />SD-5 <br />311 <br />SD-5 <br />311 <br />SD-5 <br />311 <br />9"Ø <br />9"Ø <br />9"Ø <br />9"Ø <br />9"Ø <br />9"Ø <br />9"Ø9"Ø <br />9"Ø <br />12 <br />TYP <br />28 <br />2 <br />DO NOT FASTEN TO HOODS <br />CEILING TILE. <br />REFER TO <br />REFLECTED <br />CEILING PLAN <br />HOOD <br />8 GA. HANGER WIRE AT <br />4'-0" O.C. G.C. TO <br />SUSPEND TRACK FROM <br />STRUCTURE ABOVE <br />2 <br />CEILING DETAIL @ HOOD <br />3" = 1'-0" <br />B.O. SOFFIT <br />7'-1" AFF <br />2X4'S @ 16" O.C. <br />2x8 BLOCKING @ 16" <br />O.C. CONNECT TO EA. <br />TRUSS W/ SIMPSON A35 <br />(N) CONT. 2X6 ONE BAY <br />BEYOND <br />FRP OVER 5 <br />8" TYPE "X" <br />GYP. BD. <br />BLOCKING <br />(4) - 16d MIN. <br />2X4 LEDGER W/ <br />(3) 16d MIN. EACH STUD <br />3SOFFIT - ELEC. PANELS <br />3/4" = 1'-0" <br />CONNECTED BY <br />SIMPSON TIE <br />SIMPSON TIE <br />CONT. 18 GA <br />TRACK CONNECT TO <br />STRUCTURE ABOVE <br />5/8" GYP. BD.6" STEEL STUD FRAMING <br />@16" O.C. <br />T-GRID CEILING <br />STEEL STUD BRACING @ <br />48" O.C. TO STRUCTURE <br />OR BLOCKING ABOVE, <br />CONNECT W/ #8 SCREWS, <br />ALTERNATING DIRECTION <br />SS CAP <br />5SOFFIT DETAIL <br /> 1-1/2" = 1'-0" <br />4HANGING DETAIL <br />3/4" = 1'-0" <br />SEAL <br />DESCRIPTIONDATEREV. <br />ISSUE DATE: **/**/**** <br />PROJECT NUMBER: ***** <br />DRAWN BY: <br />CHECKED BY: <br />SHEET NAME <br />SHEET NUMBER <br />SITE NUMBER: <br />BUILDING TYPE: <br />OWNER: <br />BASE VERSION: <br />DRAWING RELEASE: <br />PROJECT YEAR: <br />ASSET TYPE: <br />CLASSIFICATION: <br />UPGRADE CLASSIFICATION: <br />DESIGN TYPE: <br />26 <br />0 <br />0 <br /> <br />S <br /> <br />B <br />R <br />I <br />S <br />T <br />O <br />L <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />PROJECT TYPE: <br />00000 <br />GLOBAL NEXT GEN 30 <br />FREESTANDING <br />NEW <br />COMPANY/FRANCHISE <br />2022 <br />NEW BUILD <br />XXXX <br />GLOBAL <br />SPRING 2023 <br />NEW <br />GLOBAL NEXT GEN 30 <br />REN. 5/31/25 <br />ARMET DAVIS NEWLOVE & <br />ASSOCIATES, AIA ARCHITECTS <br />1330 OLYMPIC BLVD. <br />SANTA MONICA, CALIFORNIA 90404 <br />PH 310 452-5533 FAX 310 450-4742 <br />REFLECTED CEILING PLAN <br />A1.2 <br />OWNER REV.04/18/255 <br />HEALTH DEPT CORR.02/27/254 <br />BLDG DEP CORR.02/27/253 <br />Revision to 101122144, 20184845, & <br />40139890 (issued on 5/22/25) <br />Rev 1 - Bldg #101123998 <br />Elect #20186036 <br />Mech #40140439 <br />APPROVALS: <br />PLNG - C. Santana <br />BLDG/ELECT/MECH - CSG