WALL PANEL INSTALLATION DIRECTION <br />WALL PANEL INSTALLATION DIRECTION <br />FEMALE POCKET <br />NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL <br />FIELD APPLIED CONTINUOUS <br />BUTYL SEALANT (AT "WARM" <br />SIDE JOINT) <br />FIELD APPLIED CONTINUOUS <br />BUTYL SEALANT <br />(AT "WARM" SIDE JOINT) <br />MALE LEG <br />* VERIFY FIRST PANEL ENGAGEMENT AND ADJUST ACCORDINGLY <br />3 4" PHIL. PAN HEAD <br />AT PANEL BASE AND HEAD <br />DURING INSTALLATION <br />3 4" PHIL. PAN HEAD <br />AT PANEL BASE AND HEAD <br />DURING INSTALLATION <br />25 PANEL JOINT PLAN <br />VIEW( ) <br />FIELD APPLIED CONTINUOUS <br />BUTYL SEALANT <br />(AT "WARM" SIDE JOINT) <br />FIELD APPLIED CONTINUOUS <br />BUTYL SEALANT <br />CONTINUOUS BUTYL SEALANT W/ <br />MARRIAGE BEAD ACROSS PANEL <br />JOINT <br />SEALANT <br />N) <br />VAPOR BARRIER <br />(NOT BY KINGSPAN) <br />CONCRETE SLAB <br />(NOT BY KINGSPAN) <br />3 4" PHIL. PAN HEAD MAX. 12" O.C.3 1/2" X 3 1/2" X 1/4" <br />GALV. STEEL ANGLE <br />(NOT BY KINGSPAN) <br />3 4" PHIL. PAN HEAD <br />MAX. 12" O.C. <br />3 1/2" X 3 1/2" X 1/4" GALV. STEEL ANGLE <br />(NOT BY KINGSPAN) <br />BUTYL SEALANT UNDER <br />BASE ANGLE <br />VULKEM 45 SEALANT, MARRIED TO <br />JOINT SEALANT (NOT BY KINGSPAN) <br />KS INTERIOR PANEL <br />FIELD APPLIED <br />CONTINUOUS BUTYL SEALANT <br />FIELD APPLIED CONTINUOUS <br />BUTYL SEALANT <br />AT "WARM" SIDE PANEL JOINT <br />28 <br />PLAN <br />VIEW( )WALL PANEL END W/ STEEL COLUMN <br />29PLAN <br />VIEW( )WALL PANEL TRANSITION 30SECTION <br />VIEW( )FRAMED OPENING HEAD PLAN <br />VIEW( )FRAMED OPENING JAMB <br />26 27SECTION <br />VIEW( )BASE AT INTERIOR PARTITION WALL <br />KS INTERIOR PANEL <br />KS INTERIOR PANEL <br />COLOR CHART: <br />A <br />B <br />24GA. SURREY BEIGE (TYPE 1) <br />W <br />26GA. WXW0058L SURREY BEIGE <br />(TYPE 2 - EXTERIOR) <br />26GA. PMW33973 IMPERIAL WHITE <br />(TYPE 1 & 2) (INTERIOR) <br />COLD SIDE <br />"WARM" SIDE <br />COLD SIDE <br />"WARM" SIDE <br />COLD SIDE"WARM" SIDE <br />CONTINUOUS BUTYL TAPE <br />SELF ADHERING VAPOUR <br />BARRIER (NOT BY KINGSPAN) <br />CONTINUOUS BUTYL TAPE <br />MIN. 14" GAP FOR <br />F.I.P. INSTALLATION <br />CONTINUOUS BUTYL TAPE <br />3/4" PHIL. PAN HEAD @ 8" O.C. <br />"WARM" SIDECOLD SIDE <br />THROUGH BOLT FASTENER <br />(NOT BY KINGSPAN) <br />CONTINUOUS BUTYL SEALANT <br />WITH MARRIAGE BEAD ACROSS <br />PANEL JOINT <br />SELF ADHERING VAPOR <br />BARRIER (OPTIONAL <br />KINGSPAN) <br />KS INTERIOR <br />WALL PANEL <br />"WARM" SIDE <br />COLD SIDE <br />10 GA. CHANNEL FRAMING TO BE <br />CAPABLE OF SUPPORTING DOOR <br />AN) <br />SELF ADHERING VAPOR <br />BARRIER (OPTIONAL <br />KINGSPAN) <br />INTERIOR APPLICATION ONLY <br />KS INTERIOR <br />WALL PANEL <br />PHASE 1 PHASE 2 <br />APPROVER NOTE : <br />PLEASE CONFIRM PANEL <br />SEQUENCE , PHASE 1 AND PHASE 2 <br />IC-X INSIDE CORNER (NO <br />BY KINGSPAN) <br />COLD SIDE <br />"WARM" SIDE <br />3/4" PHIL. PAN HEAD <br />@ 8" O.C. <br />FASTENER <br />KINGSPAN) <br />SELF ADHERING VAPOUR <br />BARRIER (NOT BY KINGSPAN) <br />3/4" PHIL. PAN HEAD @ 8" O.C. <br />SEALANT <br />(NOT BY KINGSPAN) <br />STRUCTURAL TUBE <br />(NOT BY KINGSPAN) <br />THROUGH BOLT FASTENER <br />(NOT BY KINGSPAN) <br />SEALANT <br />(NOT BY KINGSPAN) <br />10 GA. CHANNEL FRAMING TO BE <br />CAPABLE OF SUPPORTING DOOR <br />DATE <br />DRAWN <br />SCALE <br />JOB No. <br />SHEET <br />JOB NAME <br />AKSHAY P. <br />04/28/25 <br />N.T.S. <br />3-10629 <br />ASPIRE BAKERY <br />DR <br />A <br />F <br />T <br />S <br />M <br />A <br />N <br />: <br />CO <br />N <br />T <br />A <br />C <br />T <br /> <br />N <br />U <br />M <br />B <br />E <br />R <br />: <br />CO <br />N <br />T <br />A <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />SH <br />O <br />P <br />S <br /> <br />C <br />H <br />E <br />C <br />K <br />E <br />D <br /> <br />B <br />Y <br />: <br />JO <br />B <br /> <br />N <br />A <br />M <br />E <br />: <br />CU <br />S <br />T <br />O <br />M <br />E <br />R <br /> <br />N <br />A <br />M <br />E <br />: <br />JO <br />B <br /> <br />L <br />O <br />C <br />A <br />T <br />I <br />O <br />N <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />M <br />A <br />N <br />A <br />G <br />E <br />R <br />: <br />BY <br />AS <br />P <br />I <br />R <br />E <br /> <br />B <br />A <br />K <br />E <br />R <br />Y <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br /> M <br />A <br />R <br />A <br />N <br />A <br />T <br />H <br />A <br /> <br />S <br />H <br />E <br />E <br />T <br /> <br />M <br />E <br />T <br />A <br />L <br />l <br /> <br />I <br />N <br />C <br />. <br />JO <br />H <br />N <br /> <br />M <br />E <br />L <br />E <br />N <br />D <br />E <br />S <br />(7 <br />1 <br />4 <br />) <br /> <br />2 <br />9 <br />3 <br />- <br />8 <br />4 <br />5 <br />8 <br />AK <br />S <br />H <br />A <br />Y <br /> <br />P <br />. <br />JE <br />N <br />N <br />I <br />F <br />E <br />R <br /> <br />M <br />O <br />R <br />A <br />L <br />E <br />S <br />M. <br /> <br />U <br />R <br />D <br />I <br />A <br />L <br />E <br />S <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />TH <br />E <br />S <br />E <br /> <br />S <br />H <br />O <br />P <br /> <br />D <br />R <br />A <br />W <br />I <br />N <br />G <br />S <br /> <br />W <br />E <br />R <br />E <br /> <br />C <br />R <br />E <br />A <br />T <br />E <br />D <br /> <br />U <br />S <br />I <br />N <br />G <br />TH <br />E <br /> <br />F <br />O <br />L <br />L <br />O <br />W <br />I <br />N <br />G <br /> <br />I <br />N <br />F <br />O <br />R <br />M <br />A <br />T <br />I <br />O <br />N <br /> <br />S <br />U <br />P <br />P <br />L <br />I <br />E <br />D <br /> <br />B <br />Y <br />CU <br />S <br />T <br />O <br />M <br />E <br />R <br /> <br />A <br />S <br /> <br />T <br />H <br />E <br /> <br />B <br />A <br />S <br />I <br />S <br /> <br />O <br />F <br /> <br />D <br />E <br />S <br />I <br />G <br />N <br />: <br />DA <br />T <br />E <br />: <br />PL <br />A <br />N <br />S <br />De <br />l <br />a <br />n <br />d <br /> <br />F <br />L <br />. <br /> <br />, <br />M <br />o <br />d <br />e <br />s <br />t <br />o <br /> <br />C <br />A <br />. <br />, <br /> <br />C <br />o <br />l <br />u <br />m <br />b <br />u <br />s <br /> <br />O <br />H <br />. <br />ww <br />w <br />. <br />k <br />i <br />n <br />g <br />s <br />p <br />a <br />n <br />p <br />a <br />n <br />e <br />l <br />s <br />. <br />u <br />s <br />Fa <br />x <br />: <br /> <br />( <br />3 <br />8 <br />6 <br />) <br /> <br />7 <br />3 <br />4 <br />- <br />9 <br />8 <br />0 <br />5 <br />, <br /> <br />T <br />e <br />l <br />: <br /> <br />( <br />3 <br />8 <br />6 <br />) <br /> <br />6 <br />2 <br />6 <br />- <br />6 <br />7 <br />8 <br />9 <br />R <br />04 <br />/ <br />0 <br />2 <br />/ <br />2 <br />4 <br />IS <br />S <br />U <br />E <br />D <br /> <br />F <br />O <br />R <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />A <br />N <br />D <br /> <br />C <br />O <br />N <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br /> <br />- <br /> <br />A <br />R <br />C <br />H <br />/ <br /> <br />S <br />T <br />R <br />U <br />C <br />T <br />AP <br />FO <br />R <br /> <br />A <br />P <br />P <br />R <br />O <br />V <br />A <br />L <br /> <br />0 <br />5 <br />/ <br />0 <br />9 <br />/ <br />2 <br />5 <br />AP <br />FO <br />R <br /> <br />A <br />P <br />P <br />R <br />O <br />V <br />A <br />L <br /> <br />R <br />E <br />V <br /> <br />1 <br /> <br />0 <br />6 <br />/ <br />1 <br />3 <br />/ <br />2 <br />5 <br />KIP 605 <br />(BY MSM) <br />(BY MSM) <br />(BY MSM) <br />(BY MSM) <br />(BY MSM) <br />(BY MSM) <br />(BY MSM) <br />(BY MSM) <br />(BY MSM) <br />(BY MSM) <br />(BY MSM) <br />10GA GALV. BENT PLATE <br />SEE SHEET METAL SUBMITTAL D24 <br />FOR MORE INFORMATION <br />10GA GALV. BENT PLATE <br />SEE SHEET METAL SUBMITTAL D23 <br />FOR MORE INFORMATION <br />1/2" DIA ASTM A307 GALV. THRU BOLT <br />@ 24" O.C. <br />1/2" DIA ASTM A307 GALV. THRU BOLT <br />@ 24" O.C. <br />24GA PRE-FINISHED FLASHING <br />SEE SHEET METAL SUBMITTAL <br />D11 FOR MORE INFORMATION <br />SELF-ADHERING SHEET <br />VAPOR BARRIER (MIN 3" <br />COVERAGE) (BY MSM) <br />FOAM-IN-PLACE INSULATION (BY MSM) <br />1/4" STEEL ANGLE (NOT BY KINGSPAN) <br />24GA PRE-FINISHED FLASHING, <br />COLOR TO MATCH PANEL <br />SEE SHEET METAL SUBMITTAL D11 <br />FOR MORE INFORMATION <br />UNDERLAYMENT (BY MSM) <br />STEEL COLUMN (NOT BY KINGSPAN) <br />1/4" STEEL ANGLE (NOT BY KINGSPN) <br />PAINT HEAD TO MATCH PANEL