Laserfiche WebLink
CO <br />R <br />T <br />I <br />C <br />A <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />SU <br />I <br />T <br />E <br />S <br /> <br />1 <br />0 <br />0 <br /> <br />& <br /> <br />1 <br />1 <br />0 <br />25 <br />0 <br />0 <br /> <br />R <br />E <br />D <br /> <br />H <br />I <br />L <br />L <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed2. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section <br />contractor preparing documents for work that I have contracted to perform. <br />FLEXIBLE AIR DUCT SHALL CONFORM TO <br />U.L. 181, SHALL NOT BE MORE THAN 5 FEET <br />LONG, AND SHALL NOT BE USED IN LIEU OF <br />ELBOWS OR FITTINGS, EXCEPT AT A <br />TERMINAL DEVICE. CMC 603.4.1, 603.5. <br />1 1/2" BAR SLIP, REINFORCED BAR SLIP, OR POCKET LOCK, ON 4' CENTERS. <br />1 1/2" BAR SLIP, REINFORCED BAR SLIP, OR POCKET LOCK ON 8' CENTERS WITH 1 1/2" x 1 1/2" x 1/8" ANGLES <br />ON CENTER LINE BETWEEN. <br />1 1/2" BAR SLIP, REINFORCED BAR SLIP, OR POCKET LOCK, ON 4' CENTERS WITH CROSS BREAK. <br />INSIDE LONGITUDINAL STANDING SEAMS WITH 1 1/8" x 1 1/8" x 1/8" ANGLES ON 2' CENTERS ON EXTERIOR. <br />1 1/2" STANDING SEAM ON 3' CENTERS. <br />55 THRU 6020 <br />1 1/2" STANDING SEAM ON 3' CENTERS. <br />1 1/2" BAR SLIP, REINFORCED BAR SLIP, OR POCKET LOCK, ON 4' CENTERS WITH CROSS BREAK. <br />INSIDE LONGITUDINAL STANDING SEAMS WITH 1 1/8" x 1 1/8" x 1/8" ANGLES ON 2' CENTERS ON EXTERIOR. <br />ON CENTER LINE BETWEEN. <br />1 1/2" BAR SLIP, REINFORCED BAR SLIP, OR POCKET LOCK ON 8' CENTERS WITH 1 1/2" x 1 1/2" x 1/8" ANGLES <br />1 1/2" BAR SLIP, REINFORCED BAR SLIP, OR POCKET LOCK, ON 4' CENTERS. <br />43 THRU 54 <br />31 THRU 42 <br />22 <br />1" BAR SLIP, REINFORCED BAR SLIP, OR 1" POCKET LOCK, ON 5' CENTERS. <br />1" BAR SLIP, REINFORCED BAR SLIP, OR POCKET LOCK ON 10' CENTERS WITH 1" x 1" x 1/8" ANGLES <br />ON CENTER LINE BETWEEN. <br />INSIDE LONGITUDINAL STANDING SEAMS WITH 1" x 1" x 1/8" ANGLES ON 5' CENTERS. <br />1" STANDING SEAM ON 5' CENTERS. <br />HEMMED "S" SLIP, 1" BAR SLIP, OR 1" POCKET LOCK ON 10' CENTERS WITH CROSS BREAK 1"STANDING SEAM ON 5' CENTERS. <br />ON CENTER LINE BETWEEN. <br />HEMMED "S" SLIP, 1" BAR SLIP, OR 1" POCKET LOCK ON 10' CENTERS WITH 1"x1" x 1/8" ANGLES <br />HEMMED "S" SLIP, 1" BAR SLIP, OR 1" POCKET LOCK ON 5' CENTERS. <br />19 THRU 30 <br />24 <br />DRIVE SLIP, PLAIN "S" SLIP, OR 1" POCKET LOCK13 THRU 18 <br />GALVANIZED STEEL DUCT GAGE, PER SMACNA 006-2006 HVAC DUCT CONST. STANDARDS UP TO 2" W.C. <br />U.S. STEEL STD. <br />(GAGE) <br />UP THRU 12 <br />(INCHES) <br />26 <br />DUCT DIMEN. <br />DRIVE SLIP, PLAIN "S" SLIP, OR 1" POCKET LOCK <br />MINIMUM METAL GAUGES <br />PERMISSIBLE GIRTH JOINTS AND LOGITUDINAL SEAMS <br />MAXIMUM 2 -INCH W.G. <br />STATIC NEGATIVESTATIC POSITIVE <br />MAXIMUM 10 -INCH W.G. <br />0.024 (24) <br />INCH (GAGE) <br />0.036 (20) <br />0.030 (22) <br />0.047 (18) <br />0.058 (16) <br />0.024 (24) <br />INCH (GAGE) <br />0.047 (18) <br />0.036 (20) <br />0.030 (22) <br />0.024 (24) <br />0.019 (26) <br />0.016 (28) <br />0.070 (14)0.058 (16) <br />INCH (GAGE) INCH (GAGE) <br />0.019 (26) <br />0.024 (24) <br />0.030 (22) <br />0.036 (20) <br />0.047 (18) <br />0.019 (26) <br />0.047 (18) <br />0.024 (24) <br />0.036 (20) <br />0.047 (18) <br />0.058 (16) <br />0.030 (22) <br />0.036 (20) <br />0.024 (24) <br />LOGITUDINAL SEAM SPIRAL SEAM SPIRAL SEAM LOGITUDINAL SEAM <br />STATIC POSITIVE DUCT DIAMETER <br />(INCHES) <br />0.024 (24) <br />0.036 (20) <br />0.030 (22) <br />0.019 (26) <br />0.016 (28) <br />0.016 (28) <br />INCH (GAGE) <br />0.047 (18) <br />27 THROUGH 36 <br />61 THROUGH 84 <br />51 THROUGH 60 <br />37 THROUGH 50 <br />15 THROUGH 26 <br />9 THROUGH 14 <br />3 THROUGH 8 <br />SPIRAL SEAM <br />0.058 (16) <br />0.047 (18) <br />0.036 (20) <br />0.030 (22) <br />0.024 (24) <br />0.019 (26) <br />0.016 (28) <br />MAXIMUM 2 -INCH W.G. <br />LOGITUDINAL SEAM <br />INCH (GAGE) <br /> GALVANIZED STEEL DUCT GAGE, PER 602.1 C.M.C., SMACNA 006-2006 HVAC DUCT CONST. STANDARDS <br />a. All appliances designed to be in a fixed position shall be securely fastened in place in accordance with the manufactures installation instructions. Supports for appliances shall be <br />designed and constructed to resist horizontal and vertical loads within the stress limitations of the CBC. [CMC 303.4] <br />b. All materials exposed within ducts and plenums including any above ceiling return air plenum shall be noncombustible or shall have a flame spread index not to exceed twenty-five (25) <br />and a smoke developed index not to exceed then fifty (50) when tested as a composite product in accordance with ASTM E 84 OR UL 723 and shall comply with <br />all requirements of the 2022 CMC Section 602.2. <br />c. Installation of ducts shall be in accordance with Section 603.0 of the 2022: <br />1. All ductwork for heating and cooling system or evaporative cooling system shall be conducted through duct systems constructed of metal as set forth in the <br />SMACNA HVAC Duct Construction Standard âfi Metal and Flexible. Factory made air ducts shall be approved for the use intended or shall comply with the 2022 CMC <br />referenced standards Chapter 17. <br />2. Joints and seems for duct systems shall comply with SMACNA HVAC Duct Construction Standard âfi Metal and Flexible. Joints of ducts systems shall be <br />made substantially airtight by means of tapes, mastics, gasketing, or other Crimp joints for round ducts shall have a contact lap of not less than <br />1-1/2" and shall be mechanically fastened by means of not less than 3 sheet-metals screws equally spaced around the joint, or an equivalent fastening method. <br />3. Ducts shall be supported at each change of direction and in accordance with SMACNA HVAC Duct Construction Standard âfi Metal and Flexible. <br />d. Ducts and plenums shall comply with Section 120.4 of the 2022 California Building Energy Efficiency Standards. Provide the following notes on the plans to demonstrate compliance: <br />Portions of supply-air and return-air ducts conveying heated or cooled air located in one or more of the following spaces shall be insulated to a minimum installed level of R-8: <br />a. Outdoors; or <br />b. In a space between the roof and an insulated ceiling; or <br />c. In a space directly under a roof with fixed vents or openings to the outside or unconditioned spaces; or <br />d. In an unconditioned crawlspace; or <br />e. In other unconditioned spaces. <br />1. Portions of supply-air ducts that are not in one of these spaces, including ducts buried in concrete slab, shall be insulated to a minimum installed level <br />of R-4.2 (or any higher level required by CMC Section 604.1) or be enclosed in directly conditioned space. <br />2. All factory-fabricated duct systems shall comply with UL 181 for ducts and closure systems, including collars, connections, and splices, and be labeled as complying with UL 181. <br />Environmental air duct exhaust shall terminate not less than 3 ft from a property line, 10 ft from a forced air inlet, and 3 ft from openings into the building. Environmental exhaust ducts shall not discharge <br />onto a public walkway. <br />2500 S Redhill Ave <br />#100 and #110 - <br />101113828-29 and <br />20178695 <br />04/20/23