Laserfiche WebLink
1'-6"1'-6"1'-6"1'-6"N3'3'3'3'SCALE: 3/32" = 1'-0"PV SYSTEM SITE PLANPV SYSTEM SIZE:4.345 kW DC LEGENDCONSTRUCTION NOTESRoof Azimuth: 192°Roof Tilt: 19°Roof Section 2NEW SOLAR PANELS(11) JA SOLAR JAM54S31-395/MR/(395W)WITH (6) AP SYSTEM DS3-L MICROINVERTERSMOUNTED TO THE BACK OF MODULESMOUNTED ON COMP SHINGLE ROOF1218 S MOHAWK DRROOF OBSTRUCTIONSSHEETCONTRACTORSOLGEN CONSTRUCTION LLC. 1218 S MOHAWK DR, SANTA ANA, CA 92704 APN:10957103 DATE:9/7/2023GONZALEZRESIDENCELicense#: C-10 1053344DESIGNER: OSDCORE ENERGY GROUP.ADDRESS: 2072 N MAIN STFL 2, LOGANUT 84341-1993CSLB#: 1053344PV-1ACDAC DISCONNECTLCLOAD CENTER(E)SHED STRUCTURE ONPROPERTY1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ONRESIDENTIAL STRUCTURE.2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITHTHE CBC SECTION 1609 TO WITHSTAND A BASIC WINDSPEED OF 110 MPH (3 SECOND GUST), WIND EXPOSURE C.3. THE ROOF MEMBERS ARE 2 "X 4" TRUSSES AT 24" ONCENTER. CONNECTION TO STRUCTURE SHALL NOT BEWITHIN 11" OF NAILING PLATES.4. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOTOBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDINGROOF VENTS.5. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOFSHALL BE MINIMUM 7/8" ABOVE ROOF SURFACE(INCLUDING CABLES UNDERNEATH MODULES ANDRACKING).6. ROOF ACCESS POINTS SHALL BE PROVIDED PER THEFOLLOWING (CRC R324.6, CBC 3111.3.4)6.1. LOCATED IN AREAS NOT REQUIRING PLACEMENT OFGROUND LADDERS OVER OPENINGS SUCH AS DOORSOR WINDOWS.6.2. LOCATED AT STRONG POINTS OF CONSTRUCTION INLOCATIONS WHERE ACCESS POINT DOES NOTCONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS:TREES, WIRES, OR SIGNS.7. SETBACKS AT RIDGES CAN BE REDUCED TO 18 INCHES INCOMPLIANCE WITH 2022 CFC/2021 IFC 1205.2.1.2TOTAL PLAN VIEW AREA FOR NEW SYSTEM = 2145.56 SQFTTOTAL PV AREA = 11(67.79 IN)(44.64 IN)/(144 IN^2) = 231.16 SQFT=(231.16 SQFT/ 2145.56 SQFT)100 = 10.77%TOTAL PV AREA FOR EXISTING SYSTEM=15(65 IN)(40 IN)/(144 IN^2) = 270.83 SQFT=(270.83 SQFT/ 2145.56 SQFT)100 =12.62%TOTAL PV AREA FOR NEW AND EXISTING SYSTEM.(231.16+ 270.83) SQFT/ 2145.56 SQFT = 23.39%TOTAL PV AREA POPULATES 23.39% OF TOTAL PLANVIEW AREA AND IS WITHIN THE 33% REQUIREMENT.WALKWAYDRIVEWAYINVSTRING INVERTERRoof Azimuth: 192°Roof Tilt: 19°Roof Section 1MMETER MAIN COMBOPROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINE(E) SERVICE DROPMPV INTERCONNECTION POINT.LOCATION OF METER MAIN COMBO, ACDISCONNECT & PV LOAD CENTERMOUNTED ON EXTERIOR WALL OF ASINGLE FAMILY RESIDENCELOCATION OF "RAPID SHUTDOWN" ACDISCONNECT NEC 690.12ACDLCINVLOCATION OF EXISTING ACDISCONNECT & STRING INVERTER(E) SOLAR SYSTEMCAL-FIRE ROOF LADDERACCESS POINTACDPROPERTY LINEPROPERTY LINECAL-FIRE ROOF LADDERACCESS POINTCAL-FIRE ROOF LADDERACCESS POINT(N) SOLAR SYSTEM(E) UNPERMITTEDPATIO COVERSTRUCTURESigned: 07/31/20231218 S Mohawk Dr -2018104310/3/2023