My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1218 S Mohawk Dr- need V2 & V3 - 101116729 & 20181043 - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Mohawk Dr
>
1218 S Mohawk Dr
>
1218 S Mohawk Dr- need V2 & V3 - 101116729 & 20181043 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 1:41:45 PM
Creation date
8/6/2025 9:30:24 AM
Metadata
Fields
Template:
Plan
Permit Number
20181043
101116729
Full Address
1218 S Mohawk Dr
Document Relationships
101116729 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Mohawk Dr\1218 S Mohawk Dr
20181043 - Permit
(Permit - Plan)
Path:
\Building\Permits\M\Mohawk Dr\1218 S Mohawk Dr
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ROOF SLOPE 910106217PV-3D52011121413151822S-5D431542524238262SHEETCONTRACTORSOLGEN CONSTRUCTION LLC. 1218 S MOHAWK DR, SANTA ANA, CA 92704 APN:10957103 DATE:9/7/2023GONZALEZRESIDENCELicense#: C-10 1053344DESIGNER: OSDCORE ENERGY GROUP.ADDRESS: 2072 N MAIN STFL 2, LOGANUT 84341-1993CSLB#: 1053344D4DETAIL (TRANSVERSE)NOT TO SCALED5DETAIL (LONGITUDINAL)NOT TO SCALED1RACKING DETAIL (TRANSVERSE)NOT TO SCALED3RACKING DETAIL (TOP)NOT TO SCALED2RACKING DETAIL (LONGITUDINAL)NOT TO SCALE1. ROOF MATERIAL: COMP SHINGLE2. ROOF STRUCTURE: TRUSSES3. ATTACHMENT TYPE: UNIRAC FLASHLOC4. MODULE MANUFACTURER: JA SOLAR5. MODULE MODEL: JAM54S31-395/MR/(395W)6. MODULE LENGTH: 67.79''7. MODULE WIDTH: 44.64"8. MODULE WEIGHT: 42.99 LBS.9. SEE SHEET S-1 FOR DIMENSION(S)10. MIN. FIRE OFFSET: 18"11. TRUSSES SPACING: 24" O.C.12. TRUSSES SIZE: 2 "X 4" NOMINAL13. LAG BOLT DIAMETER: 5/16 IN.14. LAG BOLT EMBEDMENT: 2.5 IN.15. TOTAL # OF ATTACHMENTS: 3016. TOTAL AREA: 231.16 SQ. FT.17. TOTAL WEIGHT: 472.89 LBS.18. WEIGHT PER ATTACHMENT: 15.76 LBS.19. DISTRIBUTED LOAD: 2.05 PSF20. MAX. HORIZONTAL STANDOFF: 72 IN.21. MAX. VERTICAL STANDOFF:LANDSCAPE: 26 IN., PORTRAIT: 43 IN.22. STANDOFF STAGGERING: YES23. RAIL MANUFACTURER AND MODEL(OR EQUIV.):EVEREST CROSSRAIL24. RAIL WEIGHT: 0.436 PLF.25. MAX. TRUSSES SPAN: 12 FT.26. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX.PV-3Signed: 07/31/20231218 S Mohawk Dr -2018104310/3/2023
The URL can be used to link to this page
Your browser does not support the video tag.