Laserfiche WebLink
1'-6"1'-6"N3'3'3'3'SCALE: 1/16" = 1'-0"PV SYSTEM SITE PLANPV SYSTEM SIZE:3.555 kW DC LEGENDCONSTRUCTION NOTESNEW SOLAR PANELS1410 N PARSONS PLSHEETCONTRACTORSOLGEN CONSTRUCTION LLC.1410 N PARSONS PL, SANTA ANA, CA 92703APN:10046201DATE:11/2/2023KINGSTONRESIDENCELicense#: C-10 1053344ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344DESIGNER: OAVCORE ENERGY GROUP.PV-1ACDAC DISCONNECTROOF OBSTRUCTIONS(E) SERVICE DROPDRIVEWAY(9) JA SOLAR JAM54S31-395/MR (395W)MODULES WITHA TIGO TS4-A-O OPTIMIZER ATTACHED TO THEBACK OF EACH MODULES MOUNTED ONCOMP SHINGLE ROOFMMETER MAIN COMBOINV STRING INVERTERRoof Azimuth: 270°Roof Tilt: 16°Roof Section 1PROPERTY LINE PROPERTY LINE(E) SOLAR SYSTEMMPV INTERCONNECTION POINT.LOCATION OF METER MAIN COMBO,AC DISCONNECT, PV LOAD CENTER &STRING INVERTER MOUNTED ONEXTERIOR WALL OF A SINGLE FAMILYRESIDENCEINVPROPERTY LINE <br />CAL-FIRE ROOF LADDERACCESS POINTPROPERTY LINE <br />PROPERTY LINECAL-FIRE ROOF LADDERACCESS POINTLOCATION OF "RAPID SHUTDOWN" ACDISCONNECT NEC 690.121. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ONRESIDENTIAL STRUCTURE.2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCEWITH THE CBC SECTION 1609 TO WITHSTAND A BASICWIND SPEED OF 110 MPH (3 SECOND GUST), WINDEXPOSURE C.3. THE ROOF MEMBERS ARE 2 "X 4" TRUSSES AT 24" ONCENTER. CONNECTION TO STRUCTURE SHALL NOT BEWITHIN 11" OF NAILING PLATES.4. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOTOBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDINGROOF VENTS.5. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOFSHALL BE MINIMUM 7/8" ABOVE ROOF SURFACE(INCLUDING CABLES UNDERNEATH MODULES ANDRACKING).6. ROOF ACCESS POINTS SHALL BE PROVIDED PER THEFOLLOWING (CRC R324.6, CBC 3111.3.4)6.1. LOCATED IN AREAS NOT REQUIRING PLACEMENT OFGROUND LADDERS OVER OPENINGS SUCH ASDOORS OR WINDOWS.6.2. LOCATED AT STRONG POINTS OF CONSTRUCTION INLOCATIONS WHERE ACCESS POINT DOES NOTCONFLICT WITH OVERHEAD OBSTRUCTIONS SUCHAS: TREES, WIRES, OR SIGNS.7. SETBACKS AT RIDGES CAN BE REDUCED TO 18 INCHES INCOMPLIANCE 2022 CFC/2021 IFC 1205.2.1.2TOTAL PLAN VIEW AREA = 2203.08 SQFTTOTAL PV AREA FOR NEW SYSTEM= 9(67.79 IN)(44.64 IN)/(144 IN^2) = 189.13 SQFT=(189.13 SQFT/ 2203.08 SQFT)100 = 8.58%TOTAL PV AREA FOR EXISTING SYSTEM=8(64.57 IN)(39.29IN)/(144 IN^2) = 140.94 SQFT=(140.94SQFT/ 2203.08 SQFT)100 =6.39%TOTAL PV AREA FOR NEW AND EXISTING SYSTEM.(140.94+ 189.13 ) SQFT/ 2203.08 SQFT = 14.98%TOTAL PV AREA POPULATES 14.98% OF TOTAL PLANVIEW AREA AND IS WITHIN THE 33% REQUIREMENT.PROPERTY LINEPROPERTY LINEPROPERTY LINEACDACDWALKWAYLCLOCATION OF EXISTING ACDISCONNECT & LOAD CENTERLCPV LOAD CENTERLC(E) STRUCTURE ON PROPERTYCAL-FIRE ROOF LADDERACCESS POINTW SUNSWEPT AVESigned: 11/08/2023Structural Only1410 N Parsons Pl -2018164112/13/2023