Laserfiche WebLink
PAGE <br />REV: B 10/14/2024 <br />FELIPE SERRANO <br />1414 S SHELTON ST, SANTA  <br />ANA, CA, 92707 <br />PROJECT NUMBER: <br />  109R-414SER1 <br />SHEET <br />DESIGNER: <br />ARUN MOHAN <br />CUSTOMER RESIDENCE: <br />TEL. (714) 299-7123 <br />APN: 013-051-21 <br />(415) 580-6920 ex3 <br />Template_version_v5_2024 02 28 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603   <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />PV-4.1 <br />ELECTRICAL CALCS <br />#ESTAMP <br />ELECTRICAL CALCS <br />SYSTEM INFORMATION <br />3.6 KW DC PHOTOVOLTAIC SYSTEM <br />     (6) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA: POWERWALL 3 1707000-XX-Y <br />     (3) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA: POWERWALL 3 1707000-XX-Y <br />SYSTEM OCPD SIZE <br />(COMBINED MAX CURRENT) X (CONTINUOUS LOAD) =  <br />112 A X 1.25 = 140 A → 140 A OVERCURRENT PROTECTIO <br />ALLOWABLE BACKFEED <br />MAX ALLOWED TOTAL GENERATION BACKFEED OCPD = MAIN BREAKER RATING = <br />   200A <br />LOADS IN MAIN PANEL: 00A LOADS + 150A GATEWAY BREAKER = 150A ≤ 200A <br />INTERCONNECTION MEETS CEC 2022: 705.12(B)(3)(3) REQUIREMENTS. <br />GATEWAY SYSTEM AC WIRE SIZING <br />MAX AC OUTPUT CURRENT = 150 A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X  <br />(CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 170A = 154.7A <br />TERMINAL RATING[110.14(C)] = <br />1/0AWG, 75°C RATED = 150A <br />150A < 154.7A   TERMINAL RATING GOVERNS CONDUCTOR SIZING  <br />150A < 150A   1/0 AWG AMPACITY OK <br />THEREFORE 1/0 AWG IS SUFFICIENT. <br />INVERTER INFORMATION <br />2400 KW DC PHOTOVOLTAIC SYSTEM <br />     (6) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA: POWERWALL 3 1707000-XX-Y <br />INVERTER OVERCURRENT PROTECTION <br />(INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  <br />48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER <br />DC WIRE SIZING <br />MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS LOAD)[690.8(B)(1)]=  <br />13.72A X 1.25 X 1.25 = 21.43A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X  <br />(CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 40A = 36.4A <br />TERMINAL RATING[110.14(C)] = <br />10 AWG,  75°C RATED = 35A <br />35A < 36.4A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />21.43A < 35A → 10 AWG AMPACITY OK <br />THEREFORE 10 AWG IS SUFFICIENT. <br />AC WIRE SIZING <br />MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = <br />48 A X 1.25 = 60 A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X  <br />(CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 75A = 68.25A <br />TERMINAL RATING[110.14(C)] = <br />6 AWG,  75°C RATED = 65A <br />65A < 68.25A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />60A < 65A → 6 AWG AMPACITY OK <br />THEREFORE 6 AWG IS SUFFICIENT. <br />SYSTEM CHARACTERISTICS <br />MAX OPEN CIRCUIT VOLTAGE   = {[((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC TEMP] + VOC} X (# MODULES /  <br />STRING) = <br />{[(-0.26 %/°C X 37.05 V) / 100] X [-2 °C - 25 °C] + 37.05 V} X 6 = 238 V <br />SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) <br />1.25 X 13.72A X 1 = 17.15 <br />INVERTER INFORMATION <br />1200 KW DC PHOTOVOLTAIC SYSTEM <br />     (3) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA: POWERWALL 3  <br />1707000-XX-Y <br />INVERTER OVERCURRENT PROTECTION <br />(INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  <br />48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER <br />DC WIRE SIZING <br />MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS  <br />LOAD)[690.8(B)(1)]=  <br />13.72A X 1.25 X 1.25 = 21.43A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE  <br />310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 40A = 36.4A <br />TERMINAL RATING[110.14(C)] = <br />10 AWG,  75°C RATED = 35A <br />35A < 36.4A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />21.43A < 35A → 10 AWG AMPACITY OK <br />THEREFORE 10 AWG IS SUFFICIENT. <br />AC WIRE SIZING <br />MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = <br />48 A X 1.25 = 60 A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE  <br />310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 75A = 68.25A <br />TERMINAL RATING[110.14(C)] = <br />6 AWG,  75°C RATED = 65A <br />65A < 68.25A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />60A < 65A → 6 AWG AMPACITY OK <br />THEREFORE 6 AWG IS SUFFICIENT. <br />SYSTEM CHARACTERISTICS <br />MAX OPEN CIRCUIT VOLTAGE   = {[((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC TEMP] +  <br />VOC} X (# MODULES / STRING) = <br />{[(-0.26 %/°C X 37.05 V) / 100] X [-2 °C - 25 °C] + 37.05 V} X 0 = 119 V <br />SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) <br />1.25 X 13.72 A X 1 = 17.15A <br />1414 S Shelton St <br />12/2/2024